메뉴 건너뛰기




Volumn 65, Issue 6, 2008, Pages 1396-1401

Esophageal echo-doppler monitoring in burn shock resuscitation: Are hemodynamic variables the critical standard guiding fgluid therapy?

Author keywords

Burns; Doppler; Esophageal; Hemodynamics; Shock resuscitation

Indexed keywords

ADULT; ARTICLE; ARTIFICIAL VENTILATION; BLOOD VOLUME; BODY SURFACE; BURN SHOCK; CARDIOPULMONARY HEMODYNAMICS; CLINICAL ARTICLE; DEPENDENT VARIABLE; DOPPLER ECHOCARDIOGRAPHY; FLUID RESUSCITATION; HEART AFTERLOAD; HEART MUSCLE CONTRACTILITY; HEART OUTPUT; HEART PRELOAD; HEART STROKE VOLUME; HEMODYNAMIC PARAMETERS; HUMAN; NON INVASIVE PROCEDURE; PRIORITY JOURNAL; RETROSPECTIVE STUDY; SYSTEMIC VASCULAR RESISTANCE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; URINE VOLUME; BURN; ECHOGRAPHY; FEMALE; FLUID THERAPY; HEART CONTRACTION; HEMODYNAMICS; LUNG BURN; MALE; METHODOLOGY; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; RESUSCITATION; SHOCK; SYSTOLE; VASCULAR RESISTANCE;

EID: 67650594259     PISSN: 00225282     EISSN: 15298809     Source Type: Journal    
DOI: 10.1097/TA.0b013e3180f62643     Document Type: Article
Times cited : (26)

References (32)
  • 1
    • 0018146548 scopus 로고
    • Pulmonary artery catheterization and thermodilution cardiac output determination in the management of critically burned patients
    • Aikawa N, Martyn JAJ, Burke JF. Pulmonary artery catheterization and thermodilution cardiac output determination in the management of critically burned patients. Am J Surg. 1978; 135: 811-817.
    • (1978) Am J Surg , vol.135 , pp. 811-817
    • Aikawa, N.1    Martyn, J.A.J.2    Burke, J.F.3
  • 2
    • 0025852141 scopus 로고
    • Adequate resuscitation of burn patients may not be measured by urine output and vital signs
    • Dries DJ, Waxman K. Adequate resuscitation of burn patients may not be measured by urine output and vital signs. Crit Care Med. 1991; 19: 327-329.
    • (1991) Crit Care Med , vol.19 , pp. 327-329
    • Dries, D.J.1    Waxman, K.2
  • 3
    • 0028868350 scopus 로고
    • Survival is predicted by early response to Swan-Ganz resuscitation in major burn injuries
    • Schiller WR, Bay RC, Mclachlan JG, Sagraves SG. Survival is predicted by early response to Swan-Ganz resuscitation in major burn injuries. Am J Surg. 1995; 170: 696-700.
    • (1995) Am J Surg , vol.170 , pp. 696-700
    • Schiller, W.R.1    Bay, R.C.2    Mclachlan, J.G.3    Sagraves, S.G.4
  • 5
    • 0034124259 scopus 로고    scopus 로고
    • Burn shock resuscitation: Tradition or evidence based medicine?
    • Holm C. Burn shock resuscitation: tradition or evidence based medicine? Resuscitation. 2000; 44: 157-164.
    • (2000) Resuscitation , vol.44 , pp. 157-164
    • Holm, C.1
  • 6
    • 33644974310 scopus 로고    scopus 로고
    • Burn shock fluid resuscitation regime revised by invasive hemodynamic monitoring
    • Guo ZR, He LX. Burn shock fluid resuscitation regime revised by invasive hemodynamic monitoring. Zhonghua Yi Xue Za Zhi. 2005; 85: 1585-1587.
    • (2005) Zhonghua Yi Xue Za Zhi , vol.85 , pp. 1585-1587
    • Guo, Z.R.1    He, L.X.2
  • 7
    • 33745119650 scopus 로고    scopus 로고
    • Correlations between cardiac output, stroke volume, central venous pressure, intraabdominal pressure and total circulating blood volume in resuscitation of major burns
    • Kuntscher MV, Germann G, Hartmann B. Correlations between cardiac output, stroke volume, central venous pressure, intraabdominal pressure and total circulating blood volume in resuscitation of major burns. Resuscitation. 2006; 70: 37-43.
    • (2006) Resuscitation , vol.70 , pp. 37-43
    • Kuntscher, M.V.1    Germann, G.2    Hartmann, B.3
  • 8
    • 0033995808 scopus 로고    scopus 로고
    • Intrathoracic blood volume as an end point in resuscitation of the severely burned: An observational study of 24 patients
    • Holm C, Melcer B, Horbrand F, Wö rl H, von Donnersmarck GH, Mü hlbauer W. Intrathoracic blood volume as an end point in resuscitation of the severely burned: an observational study of 24 patients. J Trauma. 2000; 48: 728-734.
    • (2000) J Trauma , vol.48 , pp. 728-734
    • Holm, C.1    Melcer, B.2    Horbrand, F.3    Wö rl, H.4    von Donnersmarck, G.H.5    Mü hlbauer, W.6
  • 10
    • 85048354417 scopus 로고    scopus 로고
    • Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
    • Tzenkov IG, Pena JP. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth. 2003; 90: 254-255.
    • (2003) Br J Anaesth , vol.90 , pp. 254-255
    • Tzenkov, I.G.1    Pena, J.P.2
  • 11
    • 8844239294 scopus 로고    scopus 로고
    • A clinical randomized study on the effects of invasive monitoring on burn shock resuscitation
    • Holm C, Mayr M, Tegeler J, et al. A clinical randomized study on the effects of invasive monitoring on burn shock resuscitation. Burns. 2004; 30: 798-807.
    • (2004) Burns , vol.30 , pp. 798-807
    • Holm, C.1    Mayr, M.2    Tegeler, J.3
  • 12
    • 33847255532 scopus 로고    scopus 로고
    • Decreased fluid volume to reduce organ damage: A new approach to burn shock resuscitation? A preliminary study
    • Arlati S, Storti E, Pradella V, Bucci L, Vitolo A, Pulici M. Decreased fluid volume to reduce organ damage: a new approach to burn shock resuscitation? A preliminary study. Resuscitation. 2007; 72: 371-378.
    • (2007) Resuscitation , vol.72 , pp. 371-378
    • Arlati, S.1    Storti, E.2    Pradella, V.3    Bucci, L.4    Vitolo, A.5    Pulici, M.6
  • 13
    • 30344443364 scopus 로고    scopus 로고
    • Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output
    • Collins S, Girard F, Boudreault D, et al. Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output. Can J Anaesth. 2005; 52: 978-985.
    • (2005) Can J Anaesth , vol.52 , pp. 978-985
    • Collins, S.1    Girard, F.2    Boudreault, D.3
  • 14
    • 33646739089 scopus 로고    scopus 로고
    • Esophageal Doppler monitoring for hemodynamic assessment
    • Prentice D, Sona C. Esophageal Doppler monitoring for hemodynamic assessment. Crit Care Nurs Clin North Am. 2006; 18: 189-193.
    • (2006) Crit Care Nurs Clin North Am , vol.18 , pp. 189-193
    • Prentice, D.1    Sona, C.2
  • 15
    • 33748607154 scopus 로고    scopus 로고
    • A prospective study on esophageal Doppler hemodynamic assessment in the ED
    • Rodriguez RM, Lum-Lung M, Dixon K, Nothmann A. A prospective study on esophageal Doppler hemodynamic assessment in the ED. Am J Emerg Med. 2006; 24: 658-663.
    • (2006) Am J Emerg Med , vol.24 , pp. 658-663
    • Rodriguez, R.M.1    Lum-Lung, M.2    Dixon, K.3    Nothmann, A.4
  • 16
    • 27844463495 scopus 로고    scopus 로고
    • Use of non-invasive esophageal echo-Doppler system in the ICU: A practical experience
    • Stawicki SP, Hoff WS, Cipolla J, deQuevedo R. Use of non-invasive esophageal echo-Doppler system in the ICU: a practical experience. J Trauma. 2005; 59: 506-507.
    • (2005) J Trauma , vol.59 , pp. 506-507
    • Stawicki, S.P.1    Hoff, W.S.2    Cipolla, J.3    deQuevedo, R.4
  • 17
    • 0032940509 scopus 로고    scopus 로고
    • Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients
    • Madan AK, UyBarreta VV, Aliabadi-Wahle S, et al. Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma. 1999; 46: 607-611.
    • (1999) J Trauma , vol.46 , pp. 607-611
    • Madan, A.K.1    UyBarreta, V.V.2    Aliabadi-Wahle, S.3
  • 18
    • 9644258916 scopus 로고    scopus 로고
    • Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: Esophageal Doppler monitor versus thermodilution pulmonary artery catheter
    • Kim K, Kwok I, Chang H, Han T. Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: esophageal Doppler monitor versus thermodilution pulmonary artery catheter. J Trauma. 2004; 57: 1013-1017.
    • (2004) J Trauma , vol.57 , pp. 1013-1017
    • Kim, K.1    Kwok, I.2    Chang, H.3    Han, T.4
  • 19
    • 0038342704 scopus 로고    scopus 로고
    • Doppler-based hemodynamic monitoring: A minimally invasive alternative
    • Turner MA. Doppler-based hemodynamic monitoring: a minimally invasive alternative. AACN Clin Issues. 2003; 14: 220-231.
    • (2003) AACN Clin Issues , vol.14 , pp. 220-231
    • Turner, M.A.1
  • 20
    • 0036112315 scopus 로고    scopus 로고
    • Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: A review
    • Laupland KB, Bands CJ. Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review. Can J Anaesth. 2002; 49: 393-401.
    • (2002) Can J Anaesth , vol.49 , pp. 393-401
    • Laupland, K.B.1    Bands, C.J.2
  • 21
    • 0033788304 scopus 로고    scopus 로고
    • Non-invasive cardiac monitoring by aortic blood flow measurement with the Dynemo 3000
    • Boulnois JL, Pechoux T. Non-invasive cardiac monitoring by aortic blood flow measurement with the Dynemo 3000. J Clin Monit Comput. 2000; 16: 127-140.
    • (2000) J Clin Monit Comput , vol.16 , pp. 127-140
    • Boulnois, J.L.1    Pechoux, T.2
  • 22
    • 0026561818 scopus 로고
    • Burn shock resuscitation
    • Warden GD. Burn shock resuscitation. World J Surg. 1992; 16: 16-23.
    • (1992) World J Surg , vol.16 , pp. 16-23
    • Warden, G.D.1
  • 23
    • 0035488414 scopus 로고    scopus 로고
    • An experimental study on the change in cardiac sympathetic neuroelectrophysiology in severely scalded rats during early postburn stage
    • Tang H, Tian J, Wang G. An experimental study on the change in cardiac sympathetic neuroelectrophysiology in severely scalded rats during early postburn stage. Zhonghua Shao Shang Za Zhi. 2001; 17: 272-275.
    • (2001) Zhonghua Shao Shang Za Zhi , vol.17 , pp. 272-275
    • Tang, H.1    Tian, J.2    Wang, G.3
  • 24
    • 0030238039 scopus 로고    scopus 로고
    • Cardiac contractile dysfunction in response to surgical stress including trauma, hemorrhage, and infection
    • Suzuki K, Kohno M, Aoki M, Nishina M, Ogino R, Kohama A. Cardiac contractile dysfunction in response to surgical stress including trauma, hemorrhage, and infection. Nippon Geka Gakkai Zasshi. 1996; 97: 745-751.
    • (1996) Nippon Geka Gakkai Zasshi , vol.97 , pp. 745-751
    • Suzuki, K.1    Kohno, M.2    Aoki, M.3    Nishina, M.4    Ogino, R.5    Kohama, A.6
  • 25
    • 0022976716 scopus 로고
    • The relationship between postburn increases in peripheral resistance and vasopressin
    • Hilton JG, Mcpherson MB, Marullo DS. The relationship between postburn increases in peripheral resistance and vasopressin. Burns. 1986; 12: 410-414.
    • (1986) Burns , vol.12 , pp. 410-414
    • Hilton, J.G.1    Mcpherson, M.B.2    Marullo, D.S.3
  • 26
    • 0034070433 scopus 로고    scopus 로고
    • A biopsy of the use of the Baxter formula to resuscitate burns or do we do it like Charlie did it?
    • Engrav LH, Colescott PL, Kemalyan N, et al. A biopsy of the use of the Baxter formula to resuscitate burns or do we do it like Charlie did it? J Burn Care Rehabil. 2000; 21: 91-95.
    • (2000) J Burn Care Rehabil , vol.21 , pp. 91-95
    • Engrav, L.H.1    Colescott, P.L.2    Kemalyan, N.3
  • 28
    • 0030298534 scopus 로고    scopus 로고
    • Use of invasive cardiovascular monitoring in patients with burns greater than 30% body surface area: A survey of 251 centres
    • Mansfield MD, Kinsella J. Use of invasive cardiovascular monitoring in patients with burns greater than 30% body surface area: a survey of 251 centres. Burns. 1996; 22: 549-551.
    • (1996) Burns , vol.22 , pp. 549-551
    • Mansfield, M.D.1    Kinsella, J.2
  • 29
    • 0036768257 scopus 로고    scopus 로고
    • Fluid resuscitation for burns: A double edge weapon. Letter to the editor
    • Kumar P. Fluid resuscitation for burns: a double edge weapon. Letter to the editor. Burns. 2002; 28: 613-614.
    • (2002) Burns , vol.28 , pp. 613-614
    • Kumar, P.1
  • 30
    • 0014413903 scopus 로고
    • Physiological response to crystalloid resuscitation of severe burns
    • Baxter CR, Shires GT. Physiological response to crystalloid resuscitation of severe burns. Ann N Y Acad Sci. 1968; 150: 874-894.
    • (1968) Ann N Y Acad Sci , vol.150 , pp. 874-894
    • Baxter, C.R.1    Shires, G.T.2
  • 31
    • 0003192508 scopus 로고    scopus 로고
    • Practice guidelines for burn care
    • American Burn Association
    • American Burn Association. Practice guidelines for burn care. J Burn Care Rehabil. 2001; 22: S48-S52.
    • (2001) J Burn Care Rehabil , vol.22
  • 32
    • 27844589882 scopus 로고    scopus 로고
    • The esophageal Doppler monitor is useful for fluid management during the perioperative and intensive care periods
    • Han T. The esophageal Doppler monitor is useful for fluid management during the perioperative and intensive care periods. J Trauma. 2005; 59: 505-506.
    • (2005) J Trauma , vol.59 , pp. 505-506
    • Han, T.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.