-
1
-
-
0018146548
-
Pulmonary artery catheterization and thermodilution cardiac output determination in the management of critically burned patients
-
Aikawa N, Martyn JAJ, Burke JF. Pulmonary artery catheterization and thermodilution cardiac output determination in the management of critically burned patients. Am J Surg. 1978; 135: 811-817.
-
(1978)
Am J Surg
, vol.135
, pp. 811-817
-
-
Aikawa, N.1
Martyn, J.A.J.2
Burke, J.F.3
-
2
-
-
0025852141
-
Adequate resuscitation of burn patients may not be measured by urine output and vital signs
-
Dries DJ, Waxman K. Adequate resuscitation of burn patients may not be measured by urine output and vital signs. Crit Care Med. 1991; 19: 327-329.
-
(1991)
Crit Care Med
, vol.19
, pp. 327-329
-
-
Dries, D.J.1
Waxman, K.2
-
3
-
-
0028868350
-
Survival is predicted by early response to Swan-Ganz resuscitation in major burn injuries
-
Schiller WR, Bay RC, Mclachlan JG, Sagraves SG. Survival is predicted by early response to Swan-Ganz resuscitation in major burn injuries. Am J Surg. 1995; 170: 696-700.
-
(1995)
Am J Surg
, vol.170
, pp. 696-700
-
-
Schiller, W.R.1
Bay, R.C.2
Mclachlan, J.G.3
Sagraves, S.G.4
-
4
-
-
0031019532
-
Hyperdynamic resuscitation improves survival in patients with lifethreatening burns
-
Schiller WR, Bay RC, Garren RL, Parker I, Sagraves SG. Hyperdynamic resuscitation improves survival in patients with lifethreatening burns. J Burn Care Rehabil. 1997; 18: 10-16.
-
(1997)
J Burn Care Rehabil
, vol.18
, pp. 10-16
-
-
Schiller, W.R.1
Bay, R.C.2
Garren, R.L.3
Parker, I.4
Sagraves, S.G.5
-
5
-
-
0034124259
-
Burn shock resuscitation: Tradition or evidence based medicine?
-
Holm C. Burn shock resuscitation: tradition or evidence based medicine? Resuscitation. 2000; 44: 157-164.
-
(2000)
Resuscitation
, vol.44
, pp. 157-164
-
-
Holm, C.1
-
6
-
-
33644974310
-
Burn shock fluid resuscitation regime revised by invasive hemodynamic monitoring
-
Guo ZR, He LX. Burn shock fluid resuscitation regime revised by invasive hemodynamic monitoring. Zhonghua Yi Xue Za Zhi. 2005; 85: 1585-1587.
-
(2005)
Zhonghua Yi Xue Za Zhi
, vol.85
, pp. 1585-1587
-
-
Guo, Z.R.1
He, L.X.2
-
7
-
-
33745119650
-
Correlations between cardiac output, stroke volume, central venous pressure, intraabdominal pressure and total circulating blood volume in resuscitation of major burns
-
Kuntscher MV, Germann G, Hartmann B. Correlations between cardiac output, stroke volume, central venous pressure, intraabdominal pressure and total circulating blood volume in resuscitation of major burns. Resuscitation. 2006; 70: 37-43.
-
(2006)
Resuscitation
, vol.70
, pp. 37-43
-
-
Kuntscher, M.V.1
Germann, G.2
Hartmann, B.3
-
8
-
-
0033995808
-
Intrathoracic blood volume as an end point in resuscitation of the severely burned: An observational study of 24 patients
-
Holm C, Melcer B, Horbrand F, Wö rl H, von Donnersmarck GH, Mü hlbauer W. Intrathoracic blood volume as an end point in resuscitation of the severely burned: an observational study of 24 patients. J Trauma. 2000; 48: 728-734.
-
(2000)
J Trauma
, vol.48
, pp. 728-734
-
-
Holm, C.1
Melcer, B.2
Horbrand, F.3
Wö rl, H.4
von Donnersmarck, G.H.5
Mü hlbauer, W.6
-
10
-
-
85048354417
-
Continuous and intermittent cardiac output measurement: Pulmonary artery catheter versus aortic transpulmonary technique
-
Tzenkov IG, Pena JP. Continuous and intermittent cardiac output measurement: pulmonary artery catheter versus aortic transpulmonary technique. Br J Anaesth. 2003; 90: 254-255.
-
(2003)
Br J Anaesth
, vol.90
, pp. 254-255
-
-
Tzenkov, I.G.1
Pena, J.P.2
-
11
-
-
8844239294
-
A clinical randomized study on the effects of invasive monitoring on burn shock resuscitation
-
Holm C, Mayr M, Tegeler J, et al. A clinical randomized study on the effects of invasive monitoring on burn shock resuscitation. Burns. 2004; 30: 798-807.
-
(2004)
Burns
, vol.30
, pp. 798-807
-
-
Holm, C.1
Mayr, M.2
Tegeler, J.3
-
12
-
-
33847255532
-
Decreased fluid volume to reduce organ damage: A new approach to burn shock resuscitation? A preliminary study
-
Arlati S, Storti E, Pradella V, Bucci L, Vitolo A, Pulici M. Decreased fluid volume to reduce organ damage: a new approach to burn shock resuscitation? A preliminary study. Resuscitation. 2007; 72: 371-378.
-
(2007)
Resuscitation
, vol.72
, pp. 371-378
-
-
Arlati, S.1
Storti, E.2
Pradella, V.3
Bucci, L.4
Vitolo, A.5
Pulici, M.6
-
13
-
-
30344443364
-
Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output
-
Collins S, Girard F, Boudreault D, et al. Esophageal Doppler and thermodilution are not interchangeable for determination of cardiac output. Can J Anaesth. 2005; 52: 978-985.
-
(2005)
Can J Anaesth
, vol.52
, pp. 978-985
-
-
Collins, S.1
Girard, F.2
Boudreault, D.3
-
14
-
-
33646739089
-
Esophageal Doppler monitoring for hemodynamic assessment
-
Prentice D, Sona C. Esophageal Doppler monitoring for hemodynamic assessment. Crit Care Nurs Clin North Am. 2006; 18: 189-193.
-
(2006)
Crit Care Nurs Clin North Am
, vol.18
, pp. 189-193
-
-
Prentice, D.1
Sona, C.2
-
15
-
-
33748607154
-
A prospective study on esophageal Doppler hemodynamic assessment in the ED
-
Rodriguez RM, Lum-Lung M, Dixon K, Nothmann A. A prospective study on esophageal Doppler hemodynamic assessment in the ED. Am J Emerg Med. 2006; 24: 658-663.
-
(2006)
Am J Emerg Med
, vol.24
, pp. 658-663
-
-
Rodriguez, R.M.1
Lum-Lung, M.2
Dixon, K.3
Nothmann, A.4
-
16
-
-
27844463495
-
Use of non-invasive esophageal echo-Doppler system in the ICU: A practical experience
-
Stawicki SP, Hoff WS, Cipolla J, deQuevedo R. Use of non-invasive esophageal echo-Doppler system in the ICU: a practical experience. J Trauma. 2005; 59: 506-507.
-
(2005)
J Trauma
, vol.59
, pp. 506-507
-
-
Stawicki, S.P.1
Hoff, W.S.2
Cipolla, J.3
deQuevedo, R.4
-
17
-
-
0032940509
-
Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients
-
Madan AK, UyBarreta VV, Aliabadi-Wahle S, et al. Esophageal Doppler ultrasound monitor versus pulmonary artery catheter in the hemodynamic management of critically ill surgical patients. J Trauma. 1999; 46: 607-611.
-
(1999)
J Trauma
, vol.46
, pp. 607-611
-
-
Madan, A.K.1
UyBarreta, V.V.2
Aliabadi-Wahle, S.3
-
18
-
-
9644258916
-
Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: Esophageal Doppler monitor versus thermodilution pulmonary artery catheter
-
Kim K, Kwok I, Chang H, Han T. Comparison of cardiac outputs of major burn patients undergoing extensive early escharectomy: esophageal Doppler monitor versus thermodilution pulmonary artery catheter. J Trauma. 2004; 57: 1013-1017.
-
(2004)
J Trauma
, vol.57
, pp. 1013-1017
-
-
Kim, K.1
Kwok, I.2
Chang, H.3
Han, T.4
-
19
-
-
0038342704
-
Doppler-based hemodynamic monitoring: A minimally invasive alternative
-
Turner MA. Doppler-based hemodynamic monitoring: a minimally invasive alternative. AACN Clin Issues. 2003; 14: 220-231.
-
(2003)
AACN Clin Issues
, vol.14
, pp. 220-231
-
-
Turner, M.A.1
-
20
-
-
0036112315
-
Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: A review
-
Laupland KB, Bands CJ. Utility of esophageal Doppler as a minimally invasive hemodynamic monitor: a review. Can J Anaesth. 2002; 49: 393-401.
-
(2002)
Can J Anaesth
, vol.49
, pp. 393-401
-
-
Laupland, K.B.1
Bands, C.J.2
-
21
-
-
0033788304
-
Non-invasive cardiac monitoring by aortic blood flow measurement with the Dynemo 3000
-
Boulnois JL, Pechoux T. Non-invasive cardiac monitoring by aortic blood flow measurement with the Dynemo 3000. J Clin Monit Comput. 2000; 16: 127-140.
-
(2000)
J Clin Monit Comput
, vol.16
, pp. 127-140
-
-
Boulnois, J.L.1
Pechoux, T.2
-
22
-
-
0026561818
-
Burn shock resuscitation
-
Warden GD. Burn shock resuscitation. World J Surg. 1992; 16: 16-23.
-
(1992)
World J Surg
, vol.16
, pp. 16-23
-
-
Warden, G.D.1
-
23
-
-
0035488414
-
An experimental study on the change in cardiac sympathetic neuroelectrophysiology in severely scalded rats during early postburn stage
-
Tang H, Tian J, Wang G. An experimental study on the change in cardiac sympathetic neuroelectrophysiology in severely scalded rats during early postburn stage. Zhonghua Shao Shang Za Zhi. 2001; 17: 272-275.
-
(2001)
Zhonghua Shao Shang Za Zhi
, vol.17
, pp. 272-275
-
-
Tang, H.1
Tian, J.2
Wang, G.3
-
24
-
-
0030238039
-
Cardiac contractile dysfunction in response to surgical stress including trauma, hemorrhage, and infection
-
Suzuki K, Kohno M, Aoki M, Nishina M, Ogino R, Kohama A. Cardiac contractile dysfunction in response to surgical stress including trauma, hemorrhage, and infection. Nippon Geka Gakkai Zasshi. 1996; 97: 745-751.
-
(1996)
Nippon Geka Gakkai Zasshi
, vol.97
, pp. 745-751
-
-
Suzuki, K.1
Kohno, M.2
Aoki, M.3
Nishina, M.4
Ogino, R.5
Kohama, A.6
-
25
-
-
0022976716
-
The relationship between postburn increases in peripheral resistance and vasopressin
-
Hilton JG, Mcpherson MB, Marullo DS. The relationship between postburn increases in peripheral resistance and vasopressin. Burns. 1986; 12: 410-414.
-
(1986)
Burns
, vol.12
, pp. 410-414
-
-
Hilton, J.G.1
Mcpherson, M.B.2
Marullo, D.S.3
-
26
-
-
0034070433
-
A biopsy of the use of the Baxter formula to resuscitate burns or do we do it like Charlie did it?
-
Engrav LH, Colescott PL, Kemalyan N, et al. A biopsy of the use of the Baxter formula to resuscitate burns or do we do it like Charlie did it? J Burn Care Rehabil. 2000; 21: 91-95.
-
(2000)
J Burn Care Rehabil
, vol.21
, pp. 91-95
-
-
Engrav, L.H.1
Colescott, P.L.2
Kemalyan, N.3
-
27
-
-
0036068820
-
How well does the Parkland formula estimate actual fluid resuscitation volumes?
-
Cartotto RC, Innes M, Musgrave MA, Gomez M, Cooper AB. How well does the Parkland formula estimate actual fluid resuscitation volumes? J Burn Care Rehabil. 2002; 23: 258-265.
-
(2002)
J Burn Care Rehabil
, vol.23
, pp. 258-265
-
-
Cartotto, R.C.1
Innes, M.2
Musgrave, M.A.3
Gomez, M.4
Cooper, A.B.5
-
28
-
-
0030298534
-
Use of invasive cardiovascular monitoring in patients with burns greater than 30% body surface area: A survey of 251 centres
-
Mansfield MD, Kinsella J. Use of invasive cardiovascular monitoring in patients with burns greater than 30% body surface area: a survey of 251 centres. Burns. 1996; 22: 549-551.
-
(1996)
Burns
, vol.22
, pp. 549-551
-
-
Mansfield, M.D.1
Kinsella, J.2
-
29
-
-
0036768257
-
Fluid resuscitation for burns: A double edge weapon. Letter to the editor
-
Kumar P. Fluid resuscitation for burns: a double edge weapon. Letter to the editor. Burns. 2002; 28: 613-614.
-
(2002)
Burns
, vol.28
, pp. 613-614
-
-
Kumar, P.1
-
30
-
-
0014413903
-
Physiological response to crystalloid resuscitation of severe burns
-
Baxter CR, Shires GT. Physiological response to crystalloid resuscitation of severe burns. Ann N Y Acad Sci. 1968; 150: 874-894.
-
(1968)
Ann N Y Acad Sci
, vol.150
, pp. 874-894
-
-
Baxter, C.R.1
Shires, G.T.2
-
31
-
-
0003192508
-
Practice guidelines for burn care
-
American Burn Association
-
American Burn Association. Practice guidelines for burn care. J Burn Care Rehabil. 2001; 22: S48-S52.
-
(2001)
J Burn Care Rehabil
, vol.22
-
-
-
32
-
-
27844589882
-
The esophageal Doppler monitor is useful for fluid management during the perioperative and intensive care periods
-
Han T. The esophageal Doppler monitor is useful for fluid management during the perioperative and intensive care periods. J Trauma. 2005; 59: 505-506.
-
(2005)
J Trauma
, vol.59
, pp. 505-506
-
-
Han, T.1
|