1
-
-
0021948756
-
Measurement of signal intensities in the presence of noise in MR images
-
DOI 10.1118/1.595711
-
RM Henkelman 1985 Measurement of signal intensities in the presence of noise in MR images Med Phys 12 232 233 (Pubitemid 15089010)
-
(1985)
Medical Physics
, vol.12
, Issue.2
, pp. 232-233
-
-
Henkelman, R.M.1
-
2
-
-
0028839871
-
The Rician distribution of noisy MRI data
-
H Gudbjartsson S Patz 1995 The Rician distribution of noisy MRI data Magn Reson Med 34 910 914
-
(1995)
Magn Reson Med
, vol.34
, pp. 910-914
-
-
Gudbjartsson, H.1
Patz, S.2
-
3
-
-
7544247899
-
"Squashing peanuts and smashing pumpkins": How noise distorts diffusion-weighted MR data
-
DOI 10.1002/mrm.20283
-
DK Jones PJ Basser 2004 Squashing peanuts and smashing pumpkins: how noise distorts diffusion-weighted MR data Magn Reson Med 52 979 993 (Pubitemid 39453270)
-
(2004)
Magnetic Resonance in Medicine
, vol.52
, Issue.5
, pp. 979-993
-
-
Jones, D.K.1
Basser, P.J.2
-
4
-
-
0034567198
-
Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI
-
S Skare M Hedehus ME Moseley TQ Li 2000 Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI J Magn Reson 147 340 352
-
(2000)
J Magn Reson
, vol.147
, pp. 340-352
-
-
Skare, S.1
Hedehus, M.2
Moseley, M.E.3
Li, T.Q.4
-
5
-
-
0033870213
-
Noise considerations in the determination of diffusion tensor anisotropy
-
DOI 10.1016/S0730-725X(00)00153-3, PII S0730725X00001533
-
S Skare T Li B Nordell M Ingvar 2000 Noise considerations in the determination of diffusion tensor anisotropy Magn Reson Imaging 18 659 669 (Pubitemid 30626355)
-
(2000)
Magnetic Resonance Imaging
, vol.18
, Issue.6
, pp. 659-669
-
-
Skare, S.1
Li, T.-Q.2
Nordell, B.3
Ingvar, M.4
-
8
-
-
0035178887
-
Theoretical analysis of the effects of noise on diffusion tensor imaging
-
DOI 10.1002/mrm.1315
-
AW Anderson 2001 Theoretical analysis of the effects of noise on diffusion tensor imaging Magn Reson Med 46 1174 1188 (Pubitemid 33104306)
-
(2001)
Magnetic Resonance in Medicine
, vol.46
, Issue.6
, pp. 1174-1188
-
-
Anderson, A.W.1
-
9
-
-
34547591228
-
Error propagation framework for diffusion tensor imaging via diffusion tensor representations
-
DOI 10.1109/TMI.2007.897415
-
CG Koay LC Chang C Pierpaoli PJ Basser 2007 Error propagation framework for diffusion tensor imaging via diffusion tensor representations IEEE Trans Med Imaging 26 1017 1034 (Pubitemid 47197684)
-
(2007)
IEEE Transactions on Medical Imaging
, vol.26
, Issue.8
, pp. 1017-1034
-
-
Koay, C.G.1
Chang, L.-C.2
Pierpaoli, C.3
Basser, P.J.4
-
10
-
-
33747872177
-
A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging
-
DOI 10.1016/j.jmr.2006.06.020, PII S1090780706001790, Thrid Annual Focus on Safety
-
CG Koay LC Chang JD Carew C Pierpaoli PJ Basser 2006 A unifying theoretical and algorithmic framework for least squares methods of estimation in diffusion tensor imaging J Magn Reson 182 115 125 (Pubitemid 44293446)
-
(2006)
Journal of Magnetic Resonance
, vol.182
, Issue.1
, pp. 115-125
-
-
Koay, C.G.1
Chang, L.-C.2
Carew, J.D.3
Pierpaoli, C.4
Basser, P.J.5
-
13
-
-
33846043073
-
Variance of estimated DTI-derived parameters via first-order perturbation methods
-
DOI 10.1002/mrm.21111
-
LC Chang CG Koay C Pierpaoli PJ Basser 2007 Variance of estimated DTI-derived parameters via first-order perturbation methods Magn Reson Med 57 141 149 (Pubitemid 46067943)
-
(2007)
Magnetic Resonance in Medicine
, vol.57
, Issue.1
, pp. 141-149
-
-
Chang, L.-C.1
Koay, C.G.2
Pierpaoli, C.3
Basser, P.J.4
-
14
-
-
1842533406
-
The Effect of Gradient Sampling Schemes on Measures Derived from Diffusion Tensor MRI: A Monte Carlo Study
-
DOI 10.1002/mrm.20033
-
DK Jones 2004 The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study Magn Reson Med 51 807 815 (Pubitemid 38420459)
-
(2004)
Magnetic Resonance in Medicine
, vol.51
, Issue.4
, pp. 807-815
-
-
Jones, D.K.1
-
15
-
-
51049093842
-
Investigations of a DTI-phantom with properties similar to in vivo neuronal tissue
-
Berlin
-
Laun FB, Stieltjes B, Huff S, Schad LR (2007) Investigations of a DTI-phantom with properties similar to in vivo neuronal tissue. In: Proceedings of the ISMRM. Berlin, p 1526
-
(2007)
Proceedings of the ISMRM
, pp. 1526
-
-
Laun, F.B.1
Stieltjes, B.2
Huff, S.3
Schad, L.R.4
-
16
-
-
63349098823
-
On the effects of dephasing due to local gradients in diffusion tensor imaging experiments: Relevance for diffusion tensor imaging fiber phantoms
-
doi: 10.1016/j.mri.2008.08.011(accepted)
-
Laun FB, Huff S, Stieltjes B (2008) On the effects of dephasing due to local gradients in diffusion tensor imaging experiments: relevance for diffusion tensor imaging fiber phantoms. Magn Reson Imaging. doi: 10.1016/j.mri.2008.08. 011 (accepted)
-
(2008)
Magn Reson Imaging
-
-
Laun, F.B.1
Huff, S.2
Stieltjes, B.3
-
17
-
-
0032835247
-
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
-
DOI 10.1002/(SICI)1522-2594(199909)42:3<515::AID-MRM14>3.0.CO;2-Q
-
DK Jones MA Horsfield A Simmons 1999 Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging Magn Reson Med 42 515 525 (Pubitemid 29416213)
-
(1999)
Magnetic Resonance in Medicine
, vol.42
, Issue.3
, pp. 515-525
-
-
Jones, D.K.1
Horsfield, M.A.2
Simmons, A.3
-
18
-
-
0033945138
-
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
-
DOI 10.1002/1522-2594(200007)44:1<41::AID-MRM8>3.0.CO;2-O
-
PJ Basser S Pajevic 2000 Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise Magn Reson Med 44 41 50 (Pubitemid 30439837)
-
(2000)
Magnetic Resonance in Medicine
, vol.44
, Issue.1
, pp. 41-50
-
-
Basser, P.J.1
Pajevic, S.2
-
19
-
-
33646830322
-
Diffusion tensor imaging in primary brain tumors: Reproducible quantitative analysis of corpus callosum infiltration and contralateral involvement using a probabilistic mixture model
-
DOI 10.1016/j.neuroimage.2005.12.052, PII S1053811906000164
-
B Stieltjes M Schluter B Didinger MA Weber HK Hahn P Parzer J Rexilius O Konrad-Verse HO Peitgen M Essig 2006 Diffusion tensor imaging in primary brain tumors: reproducible quantitative analysis of corpus callosum infiltration and contralateral involvement using a probabilistic mixture model Neuroimage 31 531 542 (Pubitemid 43776685)
-
(2006)
NeuroImage
, vol.31
, Issue.2
, pp. 531-542
-
-
Stieltjes, B.1
Schluter, M.2
Didinger, B.3
Weber, M.-A.4
Hahn, H.K.5
Parzer, P.6
Rexilius, J.7
Konrad-Verse, O.8
Peitgen, H.-O.9
Essig, M.10
-
20
-
-
0037227848
-
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
-
DOI 10.1002/mrm.10331
-
DK Jones 2003 Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI Magn Reson Med 49 7 12 (Pubitemid 36042328)
-
(2003)
Magnetic Resonance in Medicine
, vol.49
, Issue.1
, pp. 7-12
-
-
Jones, D.K.1
-
21
-
-
1242276121
-
Diffusion Imaging of the Human Spinal Cord and the Vertebral Column
-
DOI 10.1097/00002142-200312000-00004
-
R Bammer F Fazekas 2003 Diffusion imaging of the human spinal cord and the vertebral column Top Magn Reson Imaging 14 461 476 (Pubitemid 38233864)
-
(2003)
Topics in Magnetic Resonance Imaging
, vol.14
, Issue.6
, pp. 461-476
-
-
Bammer, R.1
Fazekas, F.2
-
23
-
-
0033661581
-
Water diffusion compartmentation and anisotropy at high b values in the human brain
-
CA Clark D Le Bihan 2000 Water diffusion compartmentation and anisotropy at high b values in the human brain Magn Reson Med 44 852 859
-
(2000)
Magn Reson Med
, vol.44
, pp. 852-859
-
-
Clark, C.A.1
Le Bihan, D.2
-
26
-
-
32544434231
-
Image contrast using the secondary and tertiary eigenvectors in diffusion tensor imaging
-
DOI 10.1002/mrm.20767
-
J Zhang PC van Zijl S Mori 2006 Image contrast using the secondary and tertiary eigenvectors in diffusion tensor imaging Magn Reson Med 55 439 449 (Pubitemid 43238114)
-
(2006)
Magnetic Resonance in Medicine
, vol.55
, Issue.2
, pp. 439-449
-
-
Zhang, J.1
Van Zijl, P.C.M.2
Mori, S.3
-
27
-
-
0035105014
-
Noise correction for the exact determination of apparent diffusion coefficients at low SNR
-
DOI 10.1002/1522-2594(200103)45:3<448::AID-MRM1059>3.0.CO;2-W
-
O Dietrich S Heiland K Sartor 2001 Noise correction for the exact determination of apparent diffusion coefficients at low SNR Magn Reson Med 45 448 453 (Pubitemid 32173272)
-
(2001)
Magnetic Resonance in Medicine
, vol.45
, Issue.3
, pp. 448-453
-
-
Dietrich, O.1
Heiland, S.2
Sartor, K.3
-
28
-
-
33750621209
-
Denoising of complex MRI data by wavelet-domain filtering: Application to high-b-value diffusion-weighted imaging
-
DOI 10.1002/mrm.21036
-
R Wirestam A Bibic J Lätt S Brockstedt F Ståhlberg 2006 Denoising of complex MRI data by wavelet-domain filtering: application to high-b-value diffusion-weighted imaging Magn Reson Med 56 1114 1120 (Pubitemid 44691354)
-
(2006)
Magnetic Resonance in Medicine
, vol.56
, Issue.5
, pp. 1114-1120
-
-
Wirestam, R.1
Bibic, A.2
Latt, J.3
Brockstedt, S.4
Stahlberg, F.5
-
29
-
-
0033062659
-
Wavelet packet denoising of magnetic resonance images: Importance of Rician noise at low SNR
-
DOI 10.1002/(SICI)1522-2594(199903)41:3<631::AID-MRM29>3.0.CO;2-Q
-
JC Wood KM Johnson 1999 Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR Magn Reson Med 41 631 635 (Pubitemid 29152910)
-
(1999)
Magnetic Resonance in Medicine
, vol.41
, Issue.3
, pp. 631-635
-
-
Wood, J.C.1
Johnson, K.M.2
-
30
-
-
55549130452
-
Maximum a posteriori estimation of diffusion tensor parameters using a Rician noise model: Why, how and but
-
JL Andersson 2008 Maximum a posteriori estimation of diffusion tensor parameters using a Rician noise model: why, how and but Neuroimage 42 4 1340 1356
-
(2008)
Neuroimage
, vol.42
, Issue.4
, pp. 1340-1356
-
-
Andersson, J.L.1
|