Volumn 37, Issue 4, 2009, Pages 1530-

Hematocrit causes the most significant error in point of care glucometers

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE;

EID: 67650498444     PISSN: 00903493     EISSN: 15300293     Source Type: Journal    
DOI: 10.1097/CCM.0b013e31819d2e8a     Document Type: Letter
Times cited : (5)

References (10)
  • 1
    • 56049106824 scopus 로고    scopus 로고
    • Accuracy of bedside glucose measurement from three glucometers in criti- cally ill patients
    • Hoedemaekers CWE, Gunnewiek JM, Prinsen MA, et al: Accuracy of bedside glucose measurement from three glucometers in criti- cally ill patients. Crit Care Med 2008; 36: 3062-3066
    • (2008) Crit Care Med , vol.36 , pp. 3062-3066
    • Hoedemaekers, C.W.E.1    Gunnewiek, J.M.2    Prinsen, M.A.3
  • 2
    • 38949097440 scopus 로고    scopus 로고
    • Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters
    • Karon BS, Griesmann L, Scott R, et al: Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters. Diabetes Technol Ther 2008; 10:111-120
    • (2008) Diabetes Technol Ther , vol.10 , pp. 111-120
    • Karon, B.S.1    Griesmann, L.2    Scott, R.3
  • 3
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different hematocrit levels on glucose measurements with handheld meters for pointof-care testing
    • Tang Z, Lee JH, Louie RF, et al: Effects of different hematocrit levels on glucose measurements with handheld meters for pointof-care testing. Arch Pathol Lab Med 2000; 124:1135-1140
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3
  • 4
    • 32044465949 scopus 로고    scopus 로고
    • Intensive insulin therapy in the medical ICU
    • Van den Berghe G, Wilmer A, Hermans G, et al: Intensive insulin therapy in the medical ICU. New Engl J Med 2006; 354:449-461
    • (2006) New Engl J Med , vol.354 , pp. 449-461
    • Van den Berghe, G.1    Wilmer, A.2    Hermans, G.3
  • 5
    • 0035829852 scopus 로고    scopus 로고
    • Intensive insulin therapy in critically ill patients
    • Van den Berghe G, Wouters P, Weekers F, et al: Intensive insulin therapy in critically ill patients. New Engl J Med 2001; 345: 1359-1367
    • (2001) New Engl J Med , vol.345 , pp. 1359-1367
    • Van den Berghe, G.1    Wouters, P.2    Weekers, F.3
  • 6
    • 0343360868 scopus 로고    scopus 로고
    • A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care
    • Hebert PC, Wells G, Blajchman MA, et al: A multicenter, randomized, controlled clinical trial of transfusion requirements in critical care. New Engl J Med 1999; 340:409-417
    • (1999) New Engl J Med , vol.340 , pp. 409-417
    • Hebert, P.C.1    Wells, G.2    Blajchman, M.A.3
  • 7
    • 55249089030 scopus 로고    scopus 로고
    • The impact of intensive insulin protocols and restrictive blood transfusion strategies on glucose measurement in American Burn Association (ABA) verified burn centers
    • Mann EA, Pidcoke HF, Salinas J, et al: The impact of intensive insulin protocols and restrictive blood transfusion strategies on glucose measurement in American Burn Association (ABA) verified burn centers. J Burn Care Res 2008; 29:718-723
    • (2008) J Burn Care Res , vol.29 , pp. 718-723
    • Mann, E.A.1    Pidcoke, H.F.2    Salinas, J.3
  • 8
    • 38149122251 scopus 로고    scopus 로고
    • Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers
    • Mann EA, Salinas J, Pidcoke HF, et al: Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers. J Trauma 2008; 64:15-21
    • (2008) J Trauma , vol.64 , pp. 15-21
    • Mann, E.A.1    Salinas, J.2    Pidcoke, H.F.3
  • 9
    • 56049101868 scopus 로고    scopus 로고
    • Point of care glucose testing - Need for a better mousetrap or time to rethink the hunt?
    • Juneja R, Zito DR: Point of care glucose testing - Need for a better mousetrap or time to rethink the hunt? Crit Care Med 2008; 36:3113-3114
    • (2008) Crit Care Med , vol.36 , pp. 3113-3114
    • Juneja, R.1    Zito, D.R.2
  • 10
    • 20344392145 scopus 로고    scopus 로고
    • Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction
    • Rao LV, Jakubiak F, Sidwell JS, et al: Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction. Clin Chim Acta 2005; 356:178-183
    • (2005) Clin Chim Acta , vol.356 , pp. 178-183
    • Rao, L.V.1    Jakubiak, F.2    Sidwell, J.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.