메뉴 건너뛰기




Volumn 392, Issue 2, 2009, Pages 126-132

Nanomolar detection of hydrogen peroxide at a new polynuclear cluster of tin pentacyanonitrosylferrate nanoparticle-modified carbon ceramic electrode

Author keywords

Amperometric sensor; Carbon ceramic; Hydrogen peroxide; Nanoparticles; Tin pentacyanonitrosylferrate

Indexed keywords

AMPEROMETRIC SENSORS; CHARGE TRANSFER; CHRONOAMPEROMETRY; CYCLIC VOLTAMMETRY; ELECTROCHEMICAL SENSORS; HYDROGEN PEROXIDE; NANOPARTICLES; OXIDATION; PEROXIDES; RATE CONSTANTS; SCANNING ELECTRON MICROSCOPY; SIGNAL TO NOISE RATIO; SOL-GELS; TIN; TIN COMPOUNDS;

EID: 67650494432     PISSN: 00032697     EISSN: 10960309     Source Type: Journal    
DOI: 10.1016/j.ab.2009.05.047     Document Type: Article
Times cited : (23)

References (44)
  • 1
    • 0000860611 scopus 로고
    • Ferrocene-conjugated polyaniline-modified enzyme electrodes for determination of peroxides in organic media
    • Wang C.-L., and Mulchandani A. Ferrocene-conjugated polyaniline-modified enzyme electrodes for determination of peroxides in organic media. Anal. Chem. 67 (1995) 1109-1114
    • (1995) Anal. Chem. , vol.67 , pp. 1109-1114
    • Wang, C.-L.1    Mulchandani, A.2
  • 4
    • 0026519294 scopus 로고
    • Temperature enhanced chemiluminescence for determination of cholesterol
    • Mike J.H., and Cleland T.J. Temperature enhanced chemiluminescence for determination of cholesterol. Anal. Chim. Acta 259 (1992) 73-78
    • (1992) Anal. Chim. Acta , vol.259 , pp. 73-78
    • Mike, J.H.1    Cleland, T.J.2
  • 5
    • 0036683070 scopus 로고    scopus 로고
    • Continuous on-line measurement of cerebral hydrogen peroxide using enzyme-modified ring-disk plastic carbon film electrode
    • Mao L., Osborne P.G., Yamamoto K., and Kato T. Continuous on-line measurement of cerebral hydrogen peroxide using enzyme-modified ring-disk plastic carbon film electrode. Anal. Chem. 74 (2002) 3684-3689
    • (2002) Anal. Chem. , vol.74 , pp. 3684-3689
    • Mao, L.1    Osborne, P.G.2    Yamamoto, K.3    Kato, T.4
  • 6
    • 27144499776 scopus 로고    scopus 로고
    • A one-step method to construct a third-generation biosensor based on horseradish peroxidase and gold nanoparticles embedded in silica sol-gel network on gold modified electrode
    • Di J., Shen C., Peng S., Tu Y., and Li S. A one-step method to construct a third-generation biosensor based on horseradish peroxidase and gold nanoparticles embedded in silica sol-gel network on gold modified electrode. Anal. Chim. Acta 553 (2005) 196-200
    • (2005) Anal. Chim. Acta , vol.553 , pp. 196-200
    • Di, J.1    Shen, C.2    Peng, S.3    Tu, Y.4    Li, S.5
  • 7
    • 6344285767 scopus 로고    scopus 로고
    • A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode
    • Zhang J., and Oyama M. A hydrogen peroxide sensor based on the peroxidase activity of hemoglobin immobilized on gold nanoparticles-modified ITO electrode. Electrochim. Acta 50 (2004) 85-90
    • (2004) Electrochim. Acta , vol.50 , pp. 85-90
    • Zhang, J.1    Oyama, M.2
  • 8
    • 84987492148 scopus 로고
    • Carbon paste electrodes modified with enzymes, tissues, and cells
    • Gorton L. Carbon paste electrodes modified with enzymes, tissues, and cells. Electroanalysis 7 (1995) 23-45
    • (1995) Electroanalysis , vol.7 , pp. 23-45
    • Gorton, L.1
  • 9
    • 0032708076 scopus 로고    scopus 로고
    • Recent developments towards disposable screen-printed biosensors incorporating a carbon ink modified with the redox mediator, Meldola's Blue
    • Wedge R., Pemberton R.M., Hart J.P., and Luxon R. Recent developments towards disposable screen-printed biosensors incorporating a carbon ink modified with the redox mediator, Meldola's Blue. Analusis 27 (1999) 570-577
    • (1999) Analusis , vol.27 , pp. 570-577
    • Wedge, R.1    Pemberton, R.M.2    Hart, J.P.3    Luxon, R.4
  • 10
    • 4544369382 scopus 로고    scopus 로고
    • Hydrogen peroxide detection at electrochemically and sol-gel derived Ir oxide films
    • Elzanowska H., Abu-Irhayem E., Skrzynecka B., and Birss V.I. Hydrogen peroxide detection at electrochemically and sol-gel derived Ir oxide films. Electroanalysis 16 (2004) 478-490
    • (2004) Electroanalysis , vol.16 , pp. 478-490
    • Elzanowska, H.1    Abu-Irhayem, E.2    Skrzynecka, B.3    Birss, V.I.4
  • 11
    • 0008379637 scopus 로고
    • Researches on chemically modified electrodes: XV. Preparation and electrochromism of the vanadium hexacyanoferrate film modified electrode
    • Dong S., and Li F. Researches on chemically modified electrodes: XV. Preparation and electrochromism of the vanadium hexacyanoferrate film modified electrode. J. Electroanal. Chem. 210 (1986) 31-44
    • (1986) J. Electroanal. Chem. , vol.210 , pp. 31-44
    • Dong, S.1    Li, F.2
  • 12
    • 0035369945 scopus 로고    scopus 로고
    • A novel potassium ion sensing based on Prussian Blue thin films
    • Ho K.-C., and Lin C.-L. A novel potassium ion sensing based on Prussian Blue thin films. Sens. Actuat. B 76 (2001) 512-518
    • (2001) Sens. Actuat. B , vol.76 , pp. 512-518
    • Ho, K.-C.1    Lin, C.-L.2
  • 13
    • 4544236234 scopus 로고    scopus 로고
    • Electrocatalytic oxidation of sulfite on cobalt pentacyanonitrosylferrate film modified glassy carbon electrode
    • Pournaghi-Azar M.H., and Sabzi R.E. Electrocatalytic oxidation of sulfite on cobalt pentacyanonitrosylferrate film modified glassy carbon electrode. Electroanalysis 16 (2004) 860-865
    • (2004) Electroanalysis , vol.16 , pp. 860-865
    • Pournaghi-Azar, M.H.1    Sabzi, R.E.2
  • 14
    • 69249154942 scopus 로고
    • Electrochemical oxidation and reduction of thin films of Prussian Blue
    • Neff V.D. Electrochemical oxidation and reduction of thin films of Prussian Blue. J. Electrochem. Soc. 125 (1978) 886-887
    • (1978) J. Electrochem. Soc. , vol.125 , pp. 886-887
    • Neff, V.D.1
  • 15
    • 0030245730 scopus 로고    scopus 로고
    • Prussian Blue-based amperometric biosensors in flow-injection analysis
    • Karyakin A.A., Karyakina E.E., and Gorton L. Prussian Blue-based amperometric biosensors in flow-injection analysis. Talanta 43 (1996) 1597-1606
    • (1996) Talanta , vol.43 , pp. 1597-1606
    • Karyakin, A.A.1    Karyakina, E.E.2    Gorton, L.3
  • 16
    • 0000855109 scopus 로고
    • Prussian Blue-based first-generation biosensor: a sensitive amperometric electrode for glucose
    • Karyakin A.A., Gitelmacher O.V., and Karyakina E.E. Prussian Blue-based first-generation biosensor: a sensitive amperometric electrode for glucose. Anal. Chem. 67 (1995) 2419-2423
    • (1995) Anal. Chem. , vol.67 , pp. 2419-2423
    • Karyakin, A.A.1    Gitelmacher, O.V.2    Karyakina, E.E.3
  • 17
    • 0031060663 scopus 로고    scopus 로고
    • Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes (part 1)
    • Jaffari S.A., and Turner A.P.F. Novel hexacyanoferrate(III) modified graphite disc electrodes and their application in enzyme electrodes (part 1). Biosens. Bioelectron. 12 (1997) 1-7
    • (1997) Biosens. Bioelectron. , vol.12 , pp. 1-7
    • Jaffari, S.A.1    Turner, A.P.F.2
  • 18
    • 0031983887 scopus 로고    scopus 로고
    • Chromium(III) hexacyanoferrate(II)-based chemical sensor for the cathodic determination of hydrogen peroxide
    • Lin M.S., Tseng T.F., and Shih W.C. Chromium(III) hexacyanoferrate(II)-based chemical sensor for the cathodic determination of hydrogen peroxide. Analyst 123 (1998) 159-163
    • (1998) Analyst , vol.123 , pp. 159-163
    • Lin, M.S.1    Tseng, T.F.2    Shih, W.C.3
  • 19
    • 0033004320 scopus 로고    scopus 로고
    • Chromium hexacyanoferrate based glucose biosensor
    • Lin M.S., and Shih W.C. Chromium hexacyanoferrate based glucose biosensor. Anal. Chim. Acta 381 (1999) 183-189
    • (1999) Anal. Chim. Acta , vol.381 , pp. 183-189
    • Lin, M.S.1    Shih, W.C.2
  • 20
    • 0035092514 scopus 로고    scopus 로고
    • Electrochemical characteristics of thin nickel hexacyanoferrate films formed on gold and thiol self-assembled monolayers modified gold electrodes
    • Zeng B., Zhao F., and Ding X. Electrochemical characteristics of thin nickel hexacyanoferrate films formed on gold and thiol self-assembled monolayers modified gold electrodes. Anal. Sci. 17 (2001) 259-264
    • (2001) Anal. Sci. , vol.17 , pp. 259-264
    • Zeng, B.1    Zhao, F.2    Ding, X.3
  • 21
    • 0037133913 scopus 로고    scopus 로고
    • Electrochemical characteristics of an aluminum electrode modified by a palladium hexacyanoferrate film, synthesized by a simple electroless procedure
    • Pournaghi-Azar M.H., and Dastangoo H. Electrochemical characteristics of an aluminum electrode modified by a palladium hexacyanoferrate film, synthesized by a simple electroless procedure. J. Electroanal. Chem. 523 (2002) 26-33
    • (2002) J. Electroanal. Chem. , vol.523 , pp. 26-33
    • Pournaghi-Azar, M.H.1    Dastangoo, H.2
  • 22
    • 0000236015 scopus 로고
    • Electrochemical study of copper-heptacyanonitrosylferrate film modified electrodes: preparation, properties, and applications
    • Gao Z., Zhang Y., Tian M., and Zhao Z. Electrochemical study of copper-heptacyanonitrosylferrate film modified electrodes: preparation, properties, and applications. J. Electroanal. Chem. 358 (1993) 161-176
    • (1993) J. Electroanal. Chem. , vol.358 , pp. 161-176
    • Gao, Z.1    Zhang, Y.2    Tian, M.3    Zhao, Z.4
  • 23
    • 0032260098 scopus 로고    scopus 로고
    • Electrochemistry of a thin cobalt(II)-heptacyanonitrosylferrate film modified glassy carbon electrode
    • Gao Z., Zhang Y., and Wang G. Electrochemistry of a thin cobalt(II)-heptacyanonitrosylferrate film modified glassy carbon electrode. Anal. Sci. 14 (1998) 1053-1058
    • (1998) Anal. Sci. , vol.14 , pp. 1053-1058
    • Gao, Z.1    Zhang, Y.2    Wang, G.3
  • 24
    • 0035943240 scopus 로고    scopus 로고
    • Films of mixed nickel(II) and thallium(I) hexacyanoferrates(III, II): voltammetric preparation and characterization
    • Kukulka-Walkiewicz J., Stroka J., Malik M.A., Kulesza P.J., and Galus Z. Films of mixed nickel(II) and thallium(I) hexacyanoferrates(III, II): voltammetric preparation and characterization. Electrochim. Acta 46 (2001) 4057-4063
    • (2001) Electrochim. Acta , vol.46 , pp. 4057-4063
    • Kukulka-Walkiewicz, J.1    Stroka, J.2    Malik, M.A.3    Kulesza, P.J.4    Galus, Z.5
  • 25
    • 0037123989 scopus 로고    scopus 로고
    • Electrochemical preparation, characterization, and application of electrodes modified with hybrid hexacyanoferrates of copper and cobalt
    • Cui X., Hong L., and Lin X. Electrochemical preparation, characterization, and application of electrodes modified with hybrid hexacyanoferrates of copper and cobalt. J. Electroanal. Chem. 526 (2002) 115-124
    • (2002) J. Electroanal. Chem. , vol.526 , pp. 115-124
    • Cui, X.1    Hong, L.2    Lin, X.3
  • 26
    • 0037076750 scopus 로고    scopus 로고
    • Spectroscopic and voltammetric studies on a lanthanum hexacyanoferrate modified electrode
    • Liu S.-Q., and Chen H.-Y. Spectroscopic and voltammetric studies on a lanthanum hexacyanoferrate modified electrode. J. Electroanal. Chem. 528 (2002) 190-195
    • (2002) J. Electroanal. Chem. , vol.528 , pp. 190-195
    • Liu, S.-Q.1    Chen, H.-Y.2
  • 27
    • 0028017255 scopus 로고
    • Voltammetric studies of composite ceramic carbon working electrodes
    • Gun G., Tsionsky M., and Lev O. Voltammetric studies of composite ceramic carbon working electrodes. Anal. Chim. Acta 294 (1994) 261-270
    • (1994) Anal. Chim. Acta , vol.294 , pp. 261-270
    • Gun, G.1    Tsionsky, M.2    Lev, O.3
  • 28
    • 0030868646 scopus 로고    scopus 로고
    • Sol-gel carbon composite electrode as an amperometric detector for liquid chromatography
    • Pamidi P.V.A., Parrado C., Kane S.A., Wang J., Smyth M.R., and Pingarrón J.M. Sol-gel carbon composite electrode as an amperometric detector for liquid chromatography. Talanta 44 (1997) 1929-1934
    • (1997) Talanta , vol.44 , pp. 1929-1934
    • Pamidi, P.V.A.1    Parrado, C.2    Kane, S.A.3    Wang, J.4    Smyth, M.R.5    Pingarrón, J.M.6
  • 29
    • 0032859410 scopus 로고    scopus 로고
    • Sol-gel materials for electrochemical biosensors
    • Wang J. Sol-gel materials for electrochemical biosensors. Anal. Chim. Acta 399 (1999) 21-27
    • (1999) Anal. Chim. Acta , vol.399 , pp. 21-27
    • Wang, J.1
  • 30
    • 4244134272 scopus 로고
    • Sol-gel-derived ceramic-carbon composite electrodes: introduction and scope of applications
    • Tsionsky M., Gun G., Glezer V., and Lev O. Sol-gel-derived ceramic-carbon composite electrodes: introduction and scope of applications. Anal. Chem. 66 (1994) 1747-1753
    • (1994) Anal. Chem. , vol.66 , pp. 1747-1753
    • Tsionsky, M.1    Gun, G.2    Glezer, V.3    Lev, O.4
  • 31
    • 0000978508 scopus 로고
    • Oxo[5, 10, 15, 20-tetra(4-pyridyl) porphyrinato] titanium(IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide
    • Matsubara C., Kawamoto N., and Takamala K. Oxo[5, 10, 15, 20-tetra(4-pyridyl) porphyrinato] titanium(IV): an ultra-high sensitivity spectrophotometric reagent for hydrogen peroxide. Analyst 117 (1992) 1781-1784
    • (1992) Analyst , vol.117 , pp. 1781-1784
    • Matsubara, C.1    Kawamoto, N.2    Takamala, K.3
  • 33
    • 0037062003 scopus 로고    scopus 로고
    • Cobalt hexacyanoferrate: compound stoichiometry, infrared spectroelectrochemistry, and photoinduced electron transfer
    • Lezna R.O., Romagnoli R., de Tacconi N.R., and Rajeshwar K. Cobalt hexacyanoferrate: compound stoichiometry, infrared spectroelectrochemistry, and photoinduced electron transfer. J. Phys. Chem. B 106 (2002) 3612-3621
    • (2002) J. Phys. Chem. B , vol.106 , pp. 3612-3621
    • Lezna, R.O.1    Romagnoli, R.2    de Tacconi, N.R.3    Rajeshwar, K.4
  • 34
    • 4544361608 scopus 로고    scopus 로고
    • Effects of a surfactant on the electrocatalytic activity of cobalt hexacyanoferrate modified glassy carbon electrode towards the oxidation of dopamine
    • Xun Z., Cai C., and Lu T. Effects of a surfactant on the electrocatalytic activity of cobalt hexacyanoferrate modified glassy carbon electrode towards the oxidation of dopamine. Electroanalysis 16 (2004) 674-683
    • (2004) Electroanalysis , vol.16 , pp. 674-683
    • Xun, Z.1    Cai, C.2    Lu, T.3
  • 35
    • 24344499505 scopus 로고    scopus 로고
    • Preparation and characterization of electrochemical and electrocatalytic behavior of a zinc pentacyanonitrosylferrate film-modified glassy carbon electrode
    • Pournaghi-Azar M.H., and Nahalparvari H. Preparation and characterization of electrochemical and electrocatalytic behavior of a zinc pentacyanonitrosylferrate film-modified glassy carbon electrode. J. Electroanal. Chem. 583 (2005) 307-317
    • (2005) J. Electroanal. Chem. , vol.583 , pp. 307-317
    • Pournaghi-Azar, M.H.1    Nahalparvari, H.2
  • 36
    • 0032154497 scopus 로고    scopus 로고
    • Comproportionation and disproportionation reactions in the electrochemical reduction of nitroprusside at a hanging mercury drop electrode in acidic solution
    • Carapuça H.M., Simao J.E.J., and Fogg A.G. Comproportionation and disproportionation reactions in the electrochemical reduction of nitroprusside at a hanging mercury drop electrode in acidic solution. J. Electroanal. Chem. 455 (1998) 93-105
    • (1998) J. Electroanal. Chem. , vol.455 , pp. 93-105
    • Carapuça, H.M.1    Simao, J.E.J.2    Fogg, A.G.3
  • 37
    • 0037040339 scopus 로고    scopus 로고
    • Preparation, characterization, and electrocatalytic oxidation properties of iron, cobalt, nickel, and indium hexacyanoferrate
    • Chen S.-M. Preparation, characterization, and electrocatalytic oxidation properties of iron, cobalt, nickel, and indium hexacyanoferrate. J. Electroanal. Chem. 521 (2002) 29-52
    • (2002) J. Electroanal. Chem. , vol.521 , pp. 29-52
    • Chen, S.-M.1
  • 38
    • 0039098931 scopus 로고
    • Bard A.J. (Ed), Marcel Dekker, New York (Chapter 3)
    • Murray R.W. In: Bard A.J. (Ed). Electroanalytical Chemistry vol. 13 (1984), Marcel Dekker, New York (Chapter 3)
    • (1984) Electroanalytical Chemistry , vol.13
    • Murray, R.W.1
  • 39
    • 49249148639 scopus 로고
    • General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems
    • Laviron E. General expression of the linear potential sweep voltammogram in the case of diffusionless electrochemical systems. J. Electroanal. Chem. 101 (1979) 19-28
    • (1979) J. Electroanal. Chem. , vol.101 , pp. 19-28
    • Laviron, E.1
  • 40
    • 0001547925 scopus 로고
    • Aldehyde biosensor based on the determination of NADH enzymically generated by aldehyde dehydrogenase
    • Pariente F., Lorenzo E., Tobalina F., and Abruna H.D. Aldehyde biosensor based on the determination of NADH enzymically generated by aldehyde dehydrogenase. Anal. Chem. 67 (1995) 3936-3944
    • (1995) Anal. Chem. , vol.67 , pp. 3936-3944
    • Pariente, F.1    Lorenzo, E.2    Tobalina, F.3    Abruna, H.D.4
  • 43
    • 0000779648 scopus 로고    scopus 로고
    • Determination of hydrogen peroxide by utilizing a cobalt(II) hexacyanoferrate-modified glassy carbon electrode as a chemical sensor
    • Lin M.S., and Jan B.I. Determination of hydrogen peroxide by utilizing a cobalt(II) hexacyanoferrate-modified glassy carbon electrode as a chemical sensor. Electroanalysis 9 (1997) 340-344
    • (1997) Electroanalysis , vol.9 , pp. 340-344
    • Lin, M.S.1    Jan, B.I.2
  • 44
    • 4544327003 scopus 로고    scopus 로고
    • Differential selectivity in electrochemical oxidation of ascorbic acid and hydrogen peroxide at the surface of functionalized ormosil-modified electrodes
    • Pandey P.C., Upadhyay B.C., and Upadhyay A.K. Differential selectivity in electrochemical oxidation of ascorbic acid and hydrogen peroxide at the surface of functionalized ormosil-modified electrodes. Anal. Chim. Acta 523 (2004) 219-223
    • (2004) Anal. Chim. Acta , vol.523 , pp. 219-223
    • Pandey, P.C.1    Upadhyay, B.C.2    Upadhyay, A.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.