Volumn 33, Issue 4, 2009, Pages 492-498

Study on long life of artificial joints by investigating optimal sliding surface geometry for improvement in wear resistance

Author keywords

Abrasive waterjet; Dimple structure; Effective life of artificial joint; Scratch marks; Sliding surface; Wear resistance

Indexed keywords

ABRASIVE WATERJET; DIMPLE STRUCTURE; EFFECTIVE LIFE OF ARTIFICIAL JOINT; SCRATCH MARKS; SLIDING SURFACE;

EID: 67650424257     PISSN: 01416359     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.precisioneng.2009.01.005     Document Type: Article
Times cited : (59)

References (7)
  • 2
    • 0029147350 scopus 로고
    • Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement
    • Maloney W.J., Smith R.L., Schmalzried T.P., Chiba J., Huene D., and Rubash H. Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. The Journal of Bone and Joint Surgery 77-A-9 (1995) 1301-1310
    • (1995) The Journal of Bone and Joint Surgery , vol.77 -A-9 , pp. 1301-1310
    • Maloney, W.J.1    Smith, R.L.2    Schmalzried, T.P.3    Chiba, J.4    Huene, D.5    Rubash, H.6
  • 4
    • 0035482023 scopus 로고    scopus 로고
    • Morphological assessment of in vivo wear of orthopaedic implants using multiscalar wavelets
    • Jiang X.Q., and Blunt L. Morphological assessment of in vivo wear of orthopaedic implants using multiscalar wavelets. Wear 250 (2001) 217-221
    • (2001) Wear , vol.250 , pp. 217-221
    • Jiang, X.Q.1    Blunt, L.2
  • 5
    • 0006581415 scopus 로고    scopus 로고
    • Implants for surgery-wear of total hip-joint prostheses. Part 1. Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test
    • ISO 14242-1
    • ISO 14242-1. Implants for surgery-wear of total hip-joint prostheses. Part 1. Loading and displacement parameters for wear-testing machines and corresponding environmental conditions for test; 2002.
    • (2002)
  • 6
    • 27144472273 scopus 로고    scopus 로고
    • Effect of heat treatment on microstructure and mechanical properties of Ni- and C-free Co-Cr-Mo alloys for medical applications
    • Lee S.H., Takahashi E., Nomura N., and Chiba A. Effect of heat treatment on microstructure and mechanical properties of Ni- and C-free Co-Cr-Mo alloys for medical applications. Materials Transactions 46-8 (2005) 1790-1793
    • (2005) Materials Transactions , vol.46-8 , pp. 1790-1793
    • Lee, S.H.1    Takahashi, E.2    Nomura, N.3    Chiba, A.4
  • 7
    • 8444237105 scopus 로고    scopus 로고
    • Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis
    • Moro T., Takatori Y., Ishihara K., Konno T., Takigawa Y., Matsushita T., et al. Surface grafting of artificial joints with a biocompatible polymer for preventing periprosthetic osteolysis. Nature Materials 3 (2004) 829-836
    • (2004) Nature Materials , vol.3 , pp. 829-836
    • Moro, T.1    Takatori, Y.2    Ishihara, K.3    Konno, T.4    Takigawa, Y.5    Matsushita, T.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.