메뉴 건너뛰기




Volumn 14, Issue 2, 2009, Pages

Photoacoustic tomography of the mouse cerebral cortex with a high-numerical-aperture-based virtual point detector

Author keywords

high numerical aperture (NA); photoacoustic tomography (PAT); virtual point detector

Indexed keywords

MAMMALS; OBJECT DETECTION; PHOTOACOUSTIC EFFECT; SIGNAL TO NOISE RATIO; TOMOGRAPHY; ULTRASONIC APPLICATIONS;

EID: 67650323930     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3122365     Document Type: Article
Times cited : (24)

References (12)
  • 1
    • 33646434247 scopus 로고    scopus 로고
    • Photoacoustic imaging in biomedicine
    • rsi RSINAK 0034-6748
    • M. H., Xu and L. H. V., Wang, " Photoacoustic imaging in biomedicine, ", Rev. Sci. Instrum., 77, 41101-41122 (2006). rsi RSINAK 0034-6748
    • (2006) Rev. Sci. Instrum. , vol.77 , pp. 41101-41122
    • Xu, M.H.1    Wang, L.H.V.2
  • 3
    • 0000429446 scopus 로고    scopus 로고
    • Three-dimensional photoacoustic imaging of blood vessels in tissue
    • opl OPLEDP 0146-9592 10.1364/OL.23.000648
    • C. G. A., Hoelen, F. F. M., de Mul, R., Pongers, and A., Dekker, " Three-dimensional photoacoustic imaging of blood vessels in tissue, ", Opt. Lett., 23, 648-650 (1998). opl OPLEDP 0146-9592 10.1364/OL.23.000648
    • (1998) Opt. Lett. , vol.23 , pp. 648-650
    • Hoelen, C.G.A.1    De Mul, F.F.M.2    Pongers, R.3    Dekker, A.4
  • 4
    • 0038391518 scopus 로고    scopus 로고
    • Noninvasive laser-induced photoacoustic tomography for structural and functional, in vivo, imaging of the brain
    • nab NABIF9 1087-0156 10.1038/nbt839
    • X. D., Wang, Y. J., Pang, G., Ku, X. Y., Xie, G., Stoica, and L. H. V., Wang, " Noninvasive laser-induced photoacoustic tomography for structural and functional, in vivo, imaging of the brain, ", Nat. Biotechnol., 21, 803-806 (2003). nab NABIF9 1087-0156 10.1038/nbt839
    • (2003) Nat. Biotechnol. , vol.21 , pp. 803-806
    • Wang, X.D.1    Pang, Y.J.2    Ku, G.3    Xie, X.Y.4    Stoica, G.5    Wang, L.H.V.6
  • 6
    • 28844438544 scopus 로고    scopus 로고
    • Analytical explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction
    • pre PLEEE8 1063-651X 10.1103/PhysRevE.67.056605
    • M., Xu and L. V., Wang, " Analytical explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction, ", Phys. Rev. E, 67, 056605 (2003). pre PLEEE8 1063-651X 10.1103/PhysRevE.67.056605
    • (2003) Phys. Rev. e , vol.67 , pp. 056605
    • Xu, M.1    Wang, L.V.2
  • 7
    • 37649027576 scopus 로고    scopus 로고
    • Universal back-projection algorithm for photoacoustic computed tomography
    • pre PLEEE8 1063-651X 10.1103/PhysRevE.71.016706
    • M. H., Xu and L. H. V., Wang, " Universal back-projection algorithm for photoacoustic computed tomography, ", Phys. Rev. E, 71, 016706 (2005). pre PLEEE8 1063-651X 10.1103/PhysRevE.71.016706
    • (2005) Phys. Rev. e , vol.71 , pp. 016706
    • Xu, M.H.1    Wang, L.H.V.2
  • 8
    • 0032860847 scopus 로고    scopus 로고
    • Thermoacoustic computed tomography-technical considerations
    • mph MPHYA6 0094-2405 10.1118/1.598688
    • R. A., Kruger, D. R., Reinecke, and G. A., Kruger, " Thermoacoustic computed tomography-technical considerations, ", Med. Phys., 26, 1832-1837 (1999). mph MPHYA6 0094-2405 10.1118/1.598688
    • (1999) Med. Phys. , vol.26 , pp. 1832-1837
    • Kruger, R.A.1    Reinecke, D.R.2    Kruger, G.A.3
  • 9
    • 33644891080 scopus 로고    scopus 로고
    • Improved, in vivo, photoacoustic microscopy based on a virtual-detector concept
    • opl OPLEDP 0146-9592 10.1364/OL.31.000474
    • M. L., Li, H. F., Zhang, K., Maslov, G., Stoica, and L. H. V., Wang, " Improved, in vivo, photoacoustic microscopy based on a virtual-detector concept, ", Opt. Lett., 31, 474-476 (2006). opl OPLEDP 0146-9592 10.1364/OL.31.000474
    • (2006) Opt. Lett. , vol.31 , pp. 474-476
    • Li, M.L.1    Zhang, H.F.2    Maslov, K.3    Stoica, G.4    Wang, L.H.V.5
  • 10
    • 34547265203 scopus 로고    scopus 로고
    • Ring-based ultrasonic virtual point detector with applications to photoacoustic tomography
    • apl APPLAB 0003-6951 10.1063/1.2749856
    • X. M., Yang, M. L., Li, and L. H. V., Wang, " Ring-based ultrasonic virtual point detector with applications to photoacoustic tomography, ", Appl. Phys. Lett., 90, 251103 (2007). apl APPLAB 0003-6951 10.1063/1.2749856
    • (2007) Appl. Phys. Lett. , vol.90 , pp. 251103
    • Yang, X.M.1    Li, M.L.2    Wang, L.H.V.3
  • 11
    • 37549030084 scopus 로고    scopus 로고
    • Photoacoustic tomography of a rat cerebral cortex with a ring-based ultrasonic virtual point detector
    • jbo JBOPFO 1083-3668 10.1117/1.2823076
    • X. M., Yang and L. V., Wang, " Photoacoustic tomography of a rat cerebral cortex with a ring-based ultrasonic virtual point detector, ", J. Biomed. Opt., 12, 060507 (2007). jbo JBOPFO 1083-3668 10.1117/1.2823076
    • (2007) J. Biomed. Opt. , vol.12 , pp. 060507
    • Yang, X.M.1    Wang, L.V.2
  • 12
    • 48349114728 scopus 로고    scopus 로고
    • High-numerical-aperture-based virtual point detectors for photoacoustic tomography
    • apl APPLAB 0003-6951 10.1063/1.2963365
    • C., Li and L. H. V., Wang, " High-numerical-aperture-based virtual point detectors for photoacoustic tomography, ", Appl. Phys. Lett., 3, 033902 (2008). apl APPLAB 0003-6951 10.1063/1.2963365
    • (2008) Appl. Phys. Lett. , vol.3 , pp. 033902
    • Li, C.1    Wang, L.H.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.