메뉴 건너뛰기




Volumn , Issue , 2008, Pages

Low power microwave systems for heartbeat rate detection at 2.4, 5.8, 10 and 16 GHz

Author keywords

Cardiopulmonary activity; Doppler effect; Heartbeat rate; Microwave systems; Non contact detection

Indexed keywords

CARDIOPULMONARY ACTIVITY; COMPARATIVE STUDIES; DIFFERENT FREQUENCY; HEARTBEAT RATE; LOW POWER; MICROWAVE SYSTEMS; NON-CONTACT DETECTION; POWER LEVELS; RATE DETECTION; VECTOR NETWORK ANALYZERS;

EID: 67650145333     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISABEL.2008.4712623     Document Type: Conference Paper
Times cited : (22)

References (10)
  • 5
    • 67650186752 scopus 로고    scopus 로고
    • http://en.wikipedia.org/wiki/Electrocardiogram
  • 6
    • 1842527440 scopus 로고    scopus 로고
    • Range correlation and I/Q performance benefits in single-chip silicon doppler radars for noncontact cardiopulmonary monitoring
    • March
    • A. D. Droitcour, O. Boric-Lubecke, V. M. Lubecke, J. Lin, G. T. A. Kovacs, "Range Correlation and I/Q Performance Benefits in Single-Chip Silicon Doppler Radars for Noncontact Cardiopulmonary Monitoring," IEEE Transactions on Microwave Theory and Techniques, Vol. 52, No. 3, March 2004, pp. 838-848.
    • (2004) IEEE Transactions on Microwave Theory and Techniques , vol.52 , Issue.3 , pp. 838-848
    • Droitcour, A.D.1    Boric-Lubecke, O.2    Lubecke, V.M.3    Lin, J.4    Kovacs, G.T.A.5
  • 8
    • 33847755555 scopus 로고    scopus 로고
    • Experiment and spectral analysis of a low-power K a-band heartbeat detector measuring from four sides of a human body
    • DOI 10.1109/TMTT.2006.884652
    • C. Li, Y. Xiao, and J. Lin, "Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring From Four Sides of a Human Body," IEEE Transactions on Microwave Theory and Techniques, Vol. 54, No. 12, December 2006, pp. 4464-4471. (Pubitemid 46372455)
    • (2006) IEEE Transactions on Microwave Theory and Techniques , vol.54 , Issue.12 , pp. 4464-4471
    • Li, C.1    Xiao, Y.2    Lin, J.3
  • 9
    • 33646747528 scopus 로고    scopus 로고
    • A Ka-band low power doppler radar system for remote detection of cardiopulmonary motion
    • 1616156, Proceedings of the 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005
    • Y. Xiao, J. Lin, O. Boric-Lubecke, and V. M. Lubecke, A K-a Band Low Power Doppler Radar System for Remote Detection of Cardiopulmonary Motion, Proceedings of the 2005 IEEE, Engineering in Medicine and Biology 27th Annual Conference, Shanghai, China, September 1-4 (2005), 7151-7154. (Pubitemid 46230628)
    • (2005) Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings , vol.7 , pp. 7151-7154
    • Xiao, Y.1    Lin, J.2    Boric-Lubecke, O.3    Lubecke, V.M.4
  • 10
    • 67650183632 scopus 로고    scopus 로고
    • Feasibility study for non-contact heartbeat detection at 2.4 GHz and 60 GHz
    • Chicago, August
    • D. Obeid, S. Sadek, G. Zaharia, G. El-Zein, "Feasibility Study for Non-Contact Heartbeat Detection at 2.4 GHz and 60 GHz," URSI GA 2008, Chicago, August 2008.
    • (2008) URSI GA 2008
    • Obeid, D.1    Sadek, S.2    Zaharia, G.3    El-Zein, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.