메뉴 건너뛰기




Volumn 38, Issue 4, 2009, Pages 321-327

Vaginal tridimensionel ultrasound interest for the assessment of correct Essure® sterilization micro-insert placement;Intérêt de l'échographie 3D vaginale pour le contrôle du positionnement des dispositifs Essure®

Author keywords

3D ultrasound; Essure ; Hysteroscopic sterilisation

Indexed keywords

ADULT; ARTICLE; CLINICAL ARTICLE; CLINICAL ASSESSMENT; FEMALE; GENERAL PRACTICE; GYNECOLOGY; HUMAN; HYSTEROSCOPY; IMAGE QUALITY; INSTRUMENT STERILIZATION; REPRODUCIBILITY; THREE DIMENSIONAL IMAGING; TRANSVAGINAL ECHOGRAPHY; UTERINE TUBE; UTERUS CAVITY;

EID: 67650088030     PISSN: 03682315     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jgyn.2009.03.014     Document Type: Article
Times cited : (11)

References (10)
  • 2
    • 0034753839 scopus 로고    scopus 로고
    • Tissue response to the STOP microcoil transcervical permanent contraceptive device: Results from a prehysterectomy study
    • DOI 10.1016/S0015-0282(01)02858-8, PII S0015028201028588
    • R.F. Valle, C.S. Carigan, and T.C. Wright Tissue response to the STOP microcoil transcervical permanent contraceptive device: result from a prehysterectomy study Fertil Steril 76 2001 974 980 (Pubitemid 33034573)
    • (2001) Fertility and Sterility , vol.76 , Issue.5 , pp. 974-980
    • Valle, R.F.1    Carignan, C.S.2    Wright, T.C.3
  • 3
    • 33744530257 scopus 로고    scopus 로고
    • Contrast infusion sonography to assess microinsert placement and tubal occlusion after Essure®
    • DOI 10.1016/j.fertnstert.2005.10.075, PII S0015028206003608
    • ® Fertil Steril 85 2006 1791 1793 (Pubitemid 43816404)
    • (2006) Fertility and Sterility , vol.85 , Issue.6 , pp. 1791-1793
    • Connor, V.F.1
  • 7
    • 20444420493 scopus 로고    scopus 로고
    • Ultrasound: An effective method for localization of the echogenic Essure sterilization micro-insert: Correlation with radiologic evaluations
    • DOI 10.1016/j.jmig.2004.12.009, PII S155346500400010X
    • ® sterilization micro-insert: correlation with radiologic evaluations J Minim Invas Gynecol 12 2005 50 54 (Pubitemid 40800351)
    • (2005) Journal of Minimally Invasive Gynecology , vol.12 , Issue.1 , pp. 50-54
    • Kerin, J.F.1    Levy, B.S.2
  • 9
    • 23744496862 scopus 로고    scopus 로고
    • Confirmation of Essure® microinsert tubal coil placement with conventional and volume-contrast imaging three-dimensional ultrasound
    • DOI 10.1016/j.fertnstert.2005.01.135, PII S0015028205008587
    • ® microinsert tubal coil placement with conventional and volume-contrast Imaging three-dimensional ultrasound Fertil Steril 84 2005 504 508 (Pubitemid 41125277)
    • (2005) Fertility and Sterility , vol.84 , Issue.2 , pp. 504-508
    • Thiel, J.A.1    Suchet, I.B.2    Lortie, K.3
  • 10
    • 33845983235 scopus 로고    scopus 로고
    • Intérêt de l'échographie 3D-4D en échographie fœtale et gynécologique : ppprincipes et indications
    • J.M. Levaillant Intérêt de l'échographie 3D-4D en échographie fœtale et gynécologique : principes et indications J Radiol 87 2006 1969 1992
    • (2006) J Radiol , vol.87 , pp. 1969-1992
    • Levaillant, J.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.