메뉴 건너뛰기




Volumn 21, Issue 4, 2008, Pages 446-451

Closed-loop systems for drug delivery

Author keywords

Closed loop system; Fuzzy logic; Neural network; Target controlled infusion

Indexed keywords

ALFENTANIL; DOBUTAMINE; GLUCOSE; HYPNOTIC AGENT; ISOFLURANE; MIVACURIUM; NEUROMUSCULAR BLOCKING AGENT; NITROPRUSSIDE SODIUM; NORADRENALIN; OPIATE; PHENYLEPHRINE; PROPOFOL; ROCURONIUM; SEDATIVE AGENT;

EID: 67650073671     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/ACO.0b013e3283007ecc     Document Type: Review
Times cited : (12)

References (32)
  • 1
    • 1942501152 scopus 로고    scopus 로고
    • Multiple measures of anesthesia workload during teaching and nonteaching cases
    • table of contents
    • Weinger MB, Reddy SB, Slagle JM. Multiple measures of anesthesia workload during teaching and nonteaching cases. Anesth Analg 2004; 98:1419-1425; table of contents.
    • (2004) Anesth Analg , vol.98 , pp. 1419-1425
    • Weinger, M.B.1    Reddy, S.B.2    Slagle, J.M.3
  • 2
    • 0030881501 scopus 로고    scopus 로고
    • The effect of electronic record keeping and transesophageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia
    • discussion 129A
    • Weinger MB, Herndon OW, Gaba DM. The effect of electronic record keeping and transesophageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia. Anesthesiology 1997; 87:144-155; discussion 129A.
    • (1997) Anesthesiology , vol.87 , pp. 144-155
    • Weinger, M.B.1    Herndon, O.W.2    Gaba, D.M.3
  • 3
    • 0030462158 scopus 로고    scopus 로고
    • Response times to visual and auditory alarmsduring anaesthesia
    • Morris RW, Montano SR. Response times to visual and auditory alarmsduring anaesthesia. Anaesth Intensive Care 1996; 24:682-684.
    • (1996) Anaesth Intensive Care , vol.24 , pp. 682-684
    • Morris, R.W.1    Montano, S.R.2
  • 4
    • 0029391322 scopus 로고
    • A model for technology assessment as applied to closed loop infusion systems. Technology assessment task force of the society of critical care medicine
    • Jastremski M, Jastremski C, Shepherd M, et al. A model for technology assessment as applied to closed loop infusion systems. Technology assessment task force of the society of critical care medicine. Crit Care Med 1995; 23:1745-1755.
    • (1995) Crit Care Med , vol.23 , pp. 1745-1755
    • Jastremski, M.1    Jastremski, C.2    Shepherd, M.3
  • 5
    • 0026801010 scopus 로고
    • The use of computers for controlling the delivery of anesthesia
    • O'Hara DA, Bogen DK, Noordergraaf A. The use of computers for controlling the delivery of anesthesia. Anesthesiology 1992; 77:563-581.
    • (1992) Anesthesiology , vol.77 , pp. 563-581
    • O'Hara, D.A.1    Bogen, D.K.2    Noordergraaf, A.3
  • 7
    • 0027574889 scopus 로고
    • Control strategies for arterial blood pressure regulation
    • Isaka S, Sebald AV. Control strategies for arterial blood pressure regulation. IEEE Trans Biomed Eng 1993; 40:353-363.
    • (1993) IEEE Trans Biomed Eng , vol.40 , pp. 353-363
    • Isaka, S.1    Sebald, A.V.2
  • 8
    • 33751111926 scopus 로고    scopus 로고
    • Automatic regulation of hemodynamic variables in acute heart failure by a multiple adaptive predictive controller based on neural networks
    • Kashihara K. Automatic regulation of hemodynamic variables in acute heart failure by a multiple adaptive predictive controller based on neural networks. Ann Biomed Eng 2006; 34:1846-1869.
    • (2006) Ann Biomed Eng , vol.34 , pp. 1846-1869
    • Kashihara, K.1
  • 9
    • 8644257618 scopus 로고    scopus 로고
    • Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension
    • Kashihara K, Kawada T, Uemura K, et al. Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension. Ann Biomed Eng 2004; 32:1365-1383.
    • (2004) Ann Biomed Eng , vol.32 , pp. 1365-1383
    • Kashihara, K.1    Kawada, T.2    Uemura, K.3
  • 10
    • 34547092430 scopus 로고    scopus 로고
    • Neural network adaptive output feedback control for intensive care unit sedation and intraoperative anesthesia
    • Haddad WM, Bailey JM, Hayakawa T, et al. Neural network adaptive output feedback control for intensive care unit sedation and intraoperative anesthesia. IEEE Trans Neural Netw 2007; 18:1049-1066.
    • (2007) IEEE Trans Neural Netw , vol.18 , pp. 1049-1066
    • Haddad, W.M.1    Bailey, J.M.2    Hayakawa, T.3
  • 11
    • 17144401811 scopus 로고    scopus 로고
    • A fuzzy logic based closed-loop control system for blood glucose level regulation in diabetics
    • Ibbini MS, Masadeh MA. A fuzzy logic based closed-loop control system for blood glucose level regulation in diabetics. J Med Eng Technol 2005; 29:64-69.
    • (2005) J Med Eng Technol , vol.29 , pp. 64-69
    • Ibbini, M.S.1    Masadeh, M.A.2
  • 12
    • 28344439664 scopus 로고    scopus 로고
    • Modelling and multivariable control in anaesthesia using neural-fuzzy paradigms. Part I. Classification of depth of anaesthesia and development of a patient model
    • Nunes CS, Mahfouf M, Linkens DA, et al. Modelling and multivariable control in anaesthesia using neural-fuzzy paradigms. Part I. Classification of depth of anaesthesia and development of a patient model. Artif Intell Med 2005; 35:195-206.
    • (2005) Artif Intell Med , vol.35 , pp. 195-206
    • Nunes, C.S.1    Mahfouf, M.2    Linkens, D.A.3
  • 13
    • 36549017219 scopus 로고    scopus 로고
    • Estimation of optimal modeling weights for a Bayesian-based closed-loop system for propofol administration using the bispectral index as a controlled variable: A simulation study
    • De SmetT, Struys MMRF, Greenwald S, et al. Estimation of optimal modeling weights for a Bayesian-based closed-loop system for propofol administration using the bispectral index as a controlled variable: a simulation study. Anesth Analg 2007; 105:1629-1638.
    • (2007) Anesth Analg , vol.105 , pp. 1629-1638
    • SmetT, D.1    Struys, M.M.R.F.2    Greenwald, S.3
  • 14
    • 0031834875 scopus 로고    scopus 로고
    • Pharmacokinetic concepts for TCI anaesthesia
    • Gepts E. Pharmacokinetic concepts for TCI anaesthesia. Anaesthesia 1998; 53 (Suppl 1):4 - 12.
    • (1998) Anaesthesia , vol.53 , Issue.SUPPL. 1 , pp. 4-12
    • Gepts, E.1
  • 15
    • 2942711626 scopus 로고    scopus 로고
    • Migrating from target-controlled infusion to closed-loop control in general anaesthesia
    • Ting CH, Arnott RH, Linkens DA, et al. Migrating from target-controlled infusion to closed-loop control in general anaesthesia. Comput Methods Programs Biomed 2004; 75:127-139.
    • (2004) Comput Methods Programs Biomed , vol.75 , pp. 127-139
    • Ting, C.H.1    Arnott, R.H.2    Linkens, D.A.3
  • 16
    • 33847731755 scopus 로고    scopus 로고
    • Teletherapeutic drug administration by long distance closed-loop control of propofol
    • Ihmsen H, Naguib K, Schneider G, et al. Teletherapeutic drug administration by long distance closed-loop control of propofol. Br J Anaesth 2007; 98:189-195.
    • (2007) Br J Anaesth , vol.98 , pp. 189-195
    • Ihmsen, H.1    Naguib, K.2    Schneider, G.3
  • 17
    • 33645637189 scopus 로고    scopus 로고
    • Feasibility of closed-loop titration of propofol guided by the Bispectral Indexforgeneral anaesthesia induction: A prospective randomized study
    • Liu N, Chazot T, Trillat B, et al. Feasibility of closed-loop titration of propofol guided by the Bispectral Indexforgeneral anaesthesia induction: a prospective randomized study. Eur J Anaesthesiol 2006; 23:465-469.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 465-469
    • Liu, N.1    Chazot, T.2    Trillat, B.3
  • 18
    • 28344446459 scopus 로고    scopus 로고
    • Modelling and multivariable control in anaesthesia using neural-fuzzy paradigms. Part II. Closed-loop control of simultaneous administration of propofol and remifentanil
    • Mahfouf M, Nunes CS, Linkens DA, et al. Modelling and multivariable control in anaesthesia using neural-fuzzy paradigms. Part II. Closed-loop control of simultaneous administration of propofol and remifentanil. Artif Intell Med 2005; 35:207-213.
    • (2005) Artif Intell Med , vol.35 , pp. 207-213
    • Mahfouf, M.1    Nunes, C.S.2    Linkens, D.A.3
  • 19
    • 34848899009 scopus 로고    scopus 로고
    • Closed-loop titration of propofol guided by the bispectral index
    • Liu N, Chazot T, Trillat B, et al. Closed-loop titration of propofol guided by the bispectral index. Ann Fr Anesth Reanim 2007; 26:850-854.
    • (2007) Ann Fr Anesth Reanim , vol.26 , pp. 850-854
    • Liu, N.1    Chazot, T.2    Trillat, B.3
  • 20
    • 34250622876 scopus 로고    scopus 로고
    • Closed-loop anaesthesia delivery system (CLADS) using bispectral index: A performance assessment study
    • Puri GD, Kumar B, Aveek J. Closed-loop anaesthesia delivery system (CLADS) using bispectral index: a performance assessment study. Anaesth Intensive Care 2007; 35:357-362.
    • (2007) Anaesth Intensive Care , vol.35 , pp. 357-362
    • Puri, G.D.1    Kumar, B.2    Aveek, J.3
  • 21
    • 34547678533 scopus 로고    scopus 로고
    • Closed-loop administration of propofol and remifentanil guided by the Bispectral Index in patient requiring an emergency lung volume reduction
    • Liu N, Bourgeois E, Chazot T, et al. Closed-loop administration of propofol and remifentanil guided by the Bispectral Index in patient requiring an emergency lung volume reduction. Paediatr Anaesth 2007; 17:909-910.
    • (2007) Paediatr Anaesth , vol.17 , pp. 909-910
    • Liu, N.1    Bourgeois, E.2    Chazot, T.3
  • 22
    • 34247489268 scopus 로고    scopus 로고
    • The impact of bispectral index monitoring on sedation administration in mechanically ventilated patients
    • Weatherburn C, Endacott R, Tynan P, et al. The impact of bispectral index monitoring on sedation administration in mechanically ventilated patients. Anaesth Intensive Care 2007; 35:204-208.
    • (2007) Anaesth Intensive Care , vol.35 , pp. 204-208
    • Weatherburn, C.1    Endacott, R.2    Tynan, P.3
  • 23
    • 34547559805 scopus 로고    scopus 로고
    • Prevention of awareness during anaesthesia
    • Myles PS. Prevention of awareness during anaesthesia. Best Pract Res Clin Anaesthesiol 2007; 21:345-355.
    • (2007) Best Pract Res Clin Anaesthesiol , vol.21 , pp. 345-355
    • Myles, P.S.1
  • 25
    • 0034930564 scopus 로고    scopus 로고
    • Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus 'standard practice' controlled administration
    • Struys MM, De Smet T, Versichelen LF, et al. Comparison of closed-loop controlled administration of propofol using Bispectral Index as the controlled variable versus 'standard practice' controlled administration. Anesthesiology 2001; 95:6-17.
    • (2001) Anesthesiology , vol.95 , pp. 6-17
    • Struys, M.M.1    De Smet, T.2    Versichelen, L.F.3
  • 26
    • 4344677233 scopus 로고    scopus 로고
    • A new closed-loop control system for isoflurane using bispectral index outperforms manual control
    • Locher S, Stadler KS, Boehlen T, et al. A new closed-loop control system for isoflurane using bispectral index outperforms manual control. Anesthesiology 2004; 101:591-602.
    • (2004) Anesthesiology , vol.101 , pp. 591-602
    • Locher, S.1    Stadler, K.S.2    Boehlen, T.3
  • 27
    • 33748131845 scopus 로고    scopus 로고
    • Closed-loop control of mean arterial blood pressure during surgery with alfentanil: Clinical evaluation of a novel model-based predictive controller
    • Luginbuhl M, Bieniok C, Leibundgut D, et al. Closed-loop control of mean arterial blood pressure during surgery with alfentanil: clinical evaluation of a novel model-based predictive controller. Anesthesiology 2006; 105:462-470.
    • (2006) Anesthesiology , vol.105 , pp. 462-470
    • Luginbuhl, M.1    Bieniok, C.2    Leibundgut, D.3
  • 28
    • 39749155715 scopus 로고    scopus 로고
    • Quantitation of the effect of nitrous oxide on rocuronium infusion requirements using closed-loop feedback control
    • Illman H, Antila H, Olkkola KT. Quantitation of the effect of nitrous oxide on rocuronium infusion requirements using closed-loop feedback control. Anesthesiology 2008; 108:388-391.
    • (2008) Anesthesiology , vol.108 , pp. 388-391
    • Illman, H.1    Antila, H.2    Olkkola, K.T.3
  • 29
    • 23944481905 scopus 로고    scopus 로고
    • Evaluation of a closed-loop muscle relaxation control system
    • table of contents
    • Eleveld DJ, Proost JH, Wierda JMKH. Evaluation of a closed-loop muscle relaxation control system. Anesth Analg 2005; 101:758-764; table of contents.
    • (2005) Anesth Analg , vol.101 , pp. 758-764
    • Eleveld, D.J.1    Proost, J.H.2    Wierda, J.M.K.H.3
  • 30
    • 33745684468 scopus 로고    scopus 로고
    • Model-based control of neuromuscular block using mivacurium: Design and clinical verification
    • Schumacher PM, Stadler KS, Wirz R, et al. Model-based control of neuromuscular block using mivacurium: design and clinical verification. Eur J Anaesthesiol 2006; 23:691-699.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 691-699
    • Schumacher, P.M.1    Stadler, K.S.2    Wirz, R.3
  • 31
    • 35848966557 scopus 로고    scopus 로고
    • Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: A preliminary descriptive study
    • Kee WDN, Tam YH, Khaw KS, et al. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study. Anaesthesia 2007; 62:1251-1256.
    • (2007) Anaesthesia , vol.62 , pp. 1251-1256
    • Kee, W.D.N.1    Tam, Y.H.2    Khaw, K.S.3
  • 32
    • 33745675207 scopus 로고    scopus 로고
    • Closed-loop resuscitation of burn shock
    • Hoskins SL, Elgjo GI, Lu J, et al. Closed-loop resuscitation of burn shock. J Burn Care Res 2006; 27:377-385.
    • (2006) J Burn Care Res , vol.27 , pp. 377-385
    • Hoskins, S.L.1    Elgjo, G.I.2    Lu, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.