Volumn 62, Issue 1, 2009, Pages 149-164

Analytical solution to the transient phase of steady-state free precession sequences

Author keywords

Configuration model; Look Locker; Phase cycling; SSFP; Steady state; Transient phase

Indexed keywords

CONFIGURATION MODEL; LOOK-LOCKER; PHASE CYCLING; SSFP; STEADY STATE; TRANSIENT PHASE;

EID: 67650067604     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21968     Document Type: Article
Times cited : (15)

References (27)
  • 1
    • 0001423628 scopus 로고
    • Effects of diffusion in nuclear magnetic resonance split echo experiments
    • Woessner DE. Effects of diffusion in nuclear magnetic resonance split echo experiments. J Chem Phys 1961;34:2057-2061.
    • (1961) J Chem Phys , vol.34 , pp. 2057-2061
    • Woessner, D.E.1
  • 2
    • 0000331839 scopus 로고
    • Diffusion and field-gradient effects in NMR Fourier spectroscopy
    • Kaiser R, Bartholdi E, Ernst RR. Diffusion and field-gradient effects in NMR Fourier spectroscopy. J Chem Phys 1974;60:2966-2979.
    • (1974) J Chem Phys , vol.60 , pp. 2966-2979
    • Kaiser, R.1    Bartholdi, E.2    Ernst, R.R.3
  • 3
    • 84985848260 scopus 로고
    • Echoes - How to generate, recognize, use or avoid them in MR imaging sequences
    • Hennig J. Echoes - How to generate, recognize, use or avoid them in MR imaging sequences. Concepts Magn Reson 1991;3:125-143.
    • (1991) Concepts Magn Reson , vol.3 , pp. 125-143
    • Hennig, J.1
  • 4
    • 0014732355 scopus 로고
    • Time saving in measurement of NMR and EPR relaxation times
    • Look DC, Locker DR. Time saving in measurement of NMR and EPR relaxation times. Rev Sci Instrum 1970;41:250-251.
    • (1970) Rev Sci Instrum , vol.41 , pp. 250-251
    • Look, D.C.1    Locker, D.R.2
  • 5
    • 0035095928 scopus 로고    scopus 로고
    • T1 quantification with inversion recovery True-FISP
    • Scheffler K, Hennig J. T1 quantification with inversion recovery True-FISP. Magn Reson Med 2001;45:720-723.
    • (2001) Magn Reson Med , vol.45 , pp. 720-723
    • Scheffler, K.1    Hennig, J.2
  • 6
    • 0042494544 scopus 로고    scopus 로고
    • Simplified model and stabilization of SSFP sequences
    • Le Roux P. Simplified model and stabilization of SSFP sequences. J Magn Reson 2003;163:23-37.
    • (2003) J Magn Reson , vol.163 , pp. 23-37
    • Le Roux, P.1
  • 7
    • 3543057674 scopus 로고    scopus 로고
    • Off-resonance effects in the transient response of SSFP sequences
    • Ganter C. Off-resonance effects in the transient response of SSFP sequences. Magn Reson Med 2004;52:368-375.
    • (2004) Magn Reson Med , vol.52 , pp. 368-375
    • Ganter, C.1
  • 8
    • 30344464110 scopus 로고    scopus 로고
    • A simple geometrical description of the TrueFISP ideal transient and steady-state signal
    • Schmitt P, Griswold MA, Gulani V, Haase A, Flentje M, Jakob PM. A simple geometrical description of the TrueFISP ideal transient and steady-state signal. Magn Reson Med 2006;55:177-186.
    • (2006) Magn Reson Med , vol.55 , pp. 177-186
    • Schmitt, P.1    Griswold, M.A.2    Gulani, V.3    Haase, A.4    Flentje, M.5    Jakob, P.M.6
  • 9
    • 0025985527 scopus 로고
    • Spoiling of transverse magnetization in steady-state sequences
    • Zur Y, Wood ML, Neuringer LJ. Spoiling of transverse magnetization in steady-state sequences. Magn Reson Med 1991;21:251-263.
    • (1991) Magn Reson Med , vol.21 , pp. 251-263
    • Zur, Y.1    Wood, M.L.2    Neuringer, L.J.3
  • 10
    • 30344464111 scopus 로고    scopus 로고
    • Steady state of gradient echo sequences with radiofrequency phase cycling: Analytical solution, contrast enhancement with partial spoiling
    • Ganter C. Steady state of gradient echo sequences with radiofrequency phase cycling: Analytical solution, contrast enhancement with partial spoiling. Magn Reson Med 2006;55:98-107.
    • (2006) Magn Reson Med , vol.55 , pp. 98-107
    • Ganter, C.1
  • 11
    • 0033472075 scopus 로고    scopus 로고
    • A pictorial description of steady-states in rapid magnetic resonance imaging
    • Scheffler K. A pictorial description of steady-states in rapid magnetic resonance imaging. Concept Magn Reson A 1999;11:291-304.
    • (1999) Concept Magn Reson A , vol.11 , pp. 291-304
    • Scheffler, K.1
  • 13
    • 46849109374 scopus 로고
    • Ghost artifacts of edges in RF-spoiled gradient-echo images
    • San Francisco, CA
    • Mugler JP III. Ghost artifacts of edges in RF-spoiled gradient-echo images. In: Proceedings of the 2nd Annual Meeting of ISMRM, San Francisco, CA, 1994. p 486.
    • (1994) Proceedings of the 2nd Annual Meeting of ISMRM , pp. 486
    • Mugler III, J.P.1
  • 14
    • 46849105903 scopus 로고    scopus 로고
    • Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging
    • Leupold J, Hennig J, Scheffler K. Moment and direction of the spoiler gradient for effective artifact suppression in RF-spoiled gradient echo imaging. Magn Reson Med 2008;60:119-127.
    • (2008) Magn Reson Med , vol.60 , pp. 119-127
    • Leupold, J.1    Hennig, J.2    Scheffler, K.3
  • 15
    • 33748371623 scopus 로고    scopus 로고
    • Static susceptibility effects in balanced SSFP sequences
    • Ganter C. Static susceptibility effects in balanced SSFP sequences. Magn Reson Med 2006;56:687-691.
    • (2006) Magn Reson Med , vol.56 , pp. 687-691
    • Ganter, C.1
  • 16
    • 33749177095 scopus 로고    scopus 로고
    • Steady state of echo-shifted sequences with radiofrequency phase cycling
    • Ganter C. Steady state of echo-shifted sequences with radiofrequency phase cycling. Magn Reson Med 2006;56:923-926.
    • (2006) Magn Reson Med , vol.56 , pp. 923-926
    • Ganter, C.1
  • 20
    • 0034956696 scopus 로고    scopus 로고
    • Characterization and reduction of the transient response in steady-state MR imaging
    • Hargreaves BA, Vasanawala SS, Pauly JM, Nishimura DG. Characterization and reduction of the transient response in steady-state MR imaging. Magn Reson Med 2001;46:149-158.
    • (2001) Magn Reson Med , vol.46 , pp. 149-158
    • Hargreaves, B.A.1    Vasanawala, S.S.2    Pauly, J.M.3    Nishimura, D.G.4
  • 21
    • 0025902111 scopus 로고
    • Analytical solution and verification of diffusion effect in SSFP
    • Carney CE, Wong STS, Patz S. Analytical solution and verification of diffusion effect in SSFP. Magn Reson Med 1991;19:240-246.
    • (1991) Magn Reson Med , vol.19 , pp. 240-246
    • Carney, C.E.1    Wong, S.T.S.2    Patz, S.3
  • 22
    • 0035449124 scopus 로고    scopus 로고
    • Steady-state free precession experiments and exact treatment of diffusion in a uniform gradient
    • Freed DE, Scheven UM, Zielinski LJ, Sen PN, Hürlimann MD. Steady-state free precession experiments and exact treatment of diffusion in a uniform gradient. J Chem Phys 2001;115:4249-4258.
    • (2001) J Chem Phys , vol.115 , pp. 4249-4258
    • Freed, D.E.1    Scheven, U.M.2    Zielinski, L.J.3    Sen, P.N.4    Hürlimann, M.D.5
  • 24
    • 0042385216 scopus 로고    scopus 로고
    • Reducing signal oscillations during the approach to steady state in True FISP using partial dephasing
    • Glasgow, Scotland
    • Epstein FH, Kim D, McVeigh E. Reducing signal oscillations during the approach to steady state in True FISP using partial dephasing. In: Proceedings of the 9th Annual Meeting of ISMRM, Glasgow, Scotland, 2001. p 1786.
    • (2001) Proceedings of the 9th Annual Meeting of ISMRM , pp. 1786
    • Epstein, F.H.1    Kim, D.2    McVeigh, E.3
  • 25
    • 0037229176 scopus 로고    scopus 로고
    • Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation
    • Deshpande VS, Chung YC, Zhang Q, Shea SM, Li D. Reduction of transient signal oscillations in True-FISP using a linear flip angle series magnetization preparation. Magn Reson Med 2003;49:151-157.
    • (2003) Magn Reson Med , vol.49 , pp. 151-157
    • Deshpande, V.S.1    Chung, Y.C.2    Zhang, Q.3    Shea, S.M.4    Li, D.5
  • 26
    • 16444377441 scopus 로고    scopus 로고
    • Starter sequence for steady-state free precession imaging
    • Foxall DL. Starter sequence for steady-state free precession imaging. Magn Reson Med 2005;53:919-929.
    • (2005) Magn Reson Med , vol.53 , pp. 919-929
    • Foxall, D.L.1
  • 27
    • 0035088668 scopus 로고    scopus 로고
    • Steady-state preparation for spoiled gradient echo imaging
    • Busse RF, Riederer SJ. Steady-state preparation for spoiled gradient echo imaging. Magn Reson Med 2001;45:653-661.
    • (2001) Magn Reson Med , vol.45 , pp. 653-661
    • Busse, R.F.1    Riederer, S.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.