메뉴 건너뛰기




Volumn 223, Issue 4, 2009, Pages 467-476

Determining compressor wash programmes for fouled gas turbines

Author keywords

Fouling; Offline; Online; Turbine; Washing

Indexed keywords

A PLANTS; AIRBORNE PARTICLE; CASH FLOW; COMPRESSOR FOULING; DIFFERENT SIZES; ECONOMIC PERFORMANCE; ELECTRICITY PRICES; HAZARDOUS LOCATION; OFFLINE; ONLINE; OPERATIONAL PROBLEMS; PERFORMANCE DETERIORATION; TRIAL AND ERROR;

EID: 67650045677     PISSN: 09576509     EISSN: None     Source Type: Journal    
DOI: 10.1243/09576509JPE723     Document Type: Article
Times cited : (18)

References (18)
  • 2
    • 85148735930 scopus 로고    scopus 로고
    • Fahrenheit 3600.
    • Langston, L. S. Fahrenheit 3600. Mech. Eng., 2007, 130(7), 34-37.
    • (2007) Mech. Eng , vol.130 , Issue.7 , pp. 34-37
    • Langston, L.S.1
  • 3
    • 0026844711 scopus 로고
    • Performance deterioration in industrial gas turbines
    • Diakunchak, I. S. Performance deterioration in industrial gas turbines. J. Eng. Gas Turbines Power, 1992, 114, 161-168.
    • (1992) J. Eng. Gas Turbines Power , vol.114 , pp. 161-168
    • Diakunchak, I.S.1
  • 4
    • 85069023742 scopus 로고    scopus 로고
    • available from, accessed June 2008
    • OMELweb site, available from www.omel.es, accessed June 2008.
    • OMELweb site
  • 5
    • 84888249045 scopus 로고    scopus 로고
    • Gas Turbine Tutorial - maintenance and operating practices effects on degradation and life
    • Texas A&M University, Houston, 11-13 September
    • Kurz, R. and Brun, K. Gas Turbine Tutorial - maintenance and operating practices effects on degradation and life. In Proceedings of the 36th Turbomachin-ery Symposium, Texas A&M University, Houston, 11-13 September 2007.
    • (2007) Proceedings of the 36th Turbomachin-ery Symposium
    • Kurz, R.1    Brun, K.2
  • 6
    • 33751317451 scopus 로고    scopus 로고
    • Gas turbine compressor washing: Historical developments, trends and main design parameters for online systems
    • Mund, F. C. and Pilidis, P. Gas turbine compressor washing: historical developments, trends and main design parameters for online systems. J. Eng. Gas Turbines Power, 2006, 128, 344-353.
    • (2006) J. Eng. Gas Turbines Power , vol.128 , pp. 344-353
    • Mund, F.C.1    Pilidis, P.2
  • 7
    • 0036825789 scopus 로고    scopus 로고
    • Real-time on-line performance diagnostics of heavy-duty industrial gas turbines
    • Gülen, S. C., Griffin, P. R., and Paolucci, S. Real-time on-line performance diagnostics of heavy-duty industrial gas turbines. J. Eng. Gas Turbines Power, 2002, 124, 910-921.
    • (2002) J. Eng. Gas Turbines Power , vol.124 , pp. 910-921
    • Gülen, S.C.1    Griffin, P.R.2    Paolucci, S.3
  • 8
    • 84890175568 scopus 로고
    • A proposed method for assessing the susceptibility of axial compressors to fouling
    • Seddigh, F. and Saravanamuttoo, H. I. H. A proposed method for assessing the susceptibility of axial compressors to fouling. J. Eng. Gas Turbines Power, 1991, 113, 595-601.
    • (1991) J. Eng. Gas Turbines Power , vol.113 , pp. 595-601
    • Seddigh, F.1    Saravanamuttoo, H.I.H.2
  • 9
    • 11644252341 scopus 로고    scopus 로고
    • An analysis of axial compressor fouling and a blade cleaning method
    • Tarabrin, A. P., Schurovsky, V. A., Bodrov, A. I., and Stalder, J. P. An analysis of axial compressor fouling and a blade cleaning method. J. Turbomach., 1998, 120, 256-261.
    • (1998) J. Turbomach , vol.120 , pp. 256-261
    • Tarabrin, A.P.1    Schurovsky, V.A.2    Bodrov, A.I.3    Stalder, J.P.4
  • 10
    • 0024640921 scopus 로고
    • Predicting gas turbine performance degradation due to compressor fouling using computer simulation techniques
    • Akker,G. F. and Saravanamuttoo,H. I. H. Predicting gas turbine performance degradation due to compressor fouling using computer simulation techniques. J. Eng. Gas Turbines Power, 1989, 111, 343-350.
    • (1989) J. Eng. Gas Turbines Power , vol.111 , pp. 343-350
    • Akker, G.F.1    Saravanamuttoo, H.I.H.2
  • 11
    • 85069024535 scopus 로고    scopus 로고
    • Brooks, F. J. Gas turbines performance characteristics. GE power systems [Internal] report no. GER-3567H, 2000.
    • Brooks, F. J. Gas turbines performance characteristics. GE power systems [Internal] report no. GER-3567H, 2000.
  • 13
  • 14
    • 0035301323 scopus 로고    scopus 로고
    • Gas turbine compressor washing state of the art: Field experiences
    • Stalder,J. P. Gas turbine compressor washing state of the art: field experiences. J. Eng. Gas Turbines Power, 2001, 123, 363-370.
    • (2001) J. Eng. Gas Turbines Power , vol.123 , pp. 363-370
    • Stalder, J.P.1
  • 15
    • 0003579065 scopus 로고    scopus 로고
    • Implications of engine deterioration for operational effectiveness of a military aircraft
    • Naeem, M., Singh, R., and Probert, D. Implications of engine deterioration for operational effectiveness of a military aircraft. Appl. Energy, 1998, 60, 115-152.
    • (1998) Appl. Energy , vol.60 , pp. 115-152
    • Naeem, M.1    Singh, R.2    Probert, D.3
  • 16
    • 85069028820 scopus 로고    scopus 로고
    • Badeer G. H. GE aeroderivative gas turbines - design and operating features. GE power systems [Internal] report no. GER-3695E, 2000.
    • Badeer G. H. GE aeroderivative gas turbines - design and operating features. GE power systems [Internal] report no. GER-3695E, 2000.
  • 17
    • 10244239357 scopus 로고    scopus 로고
    • Measureddatacor- rection for improved fouling and degradation analysis of offshore gas turbines
    • Viena, 14-17 June, paper no. 04-GT-53760
    • Veer,T., Haglerod, K., and Bolland, O. Measureddatacor- rection for improved fouling and degradation analysis of offshore gas turbines. In Proceedings of the ASME Turbo Expo, Viena, 14-17 June 2004, paper no. 04-GT-53760.
    • (2004) Proceedings of the ASME Turbo Expo
    • Veer, T.1    Haglerod, K.2    Bolland, O.3
  • 18
    • 85069035714 scopus 로고    scopus 로고
    • Balevic, D., Burger, R., and Forry, D. Heavy duty gas turbine operating and maintenance considerations. GE power systems [Internal] report no. GER-3260K, 2004.
    • Balevic, D., Burger, R., and Forry, D. Heavy duty gas turbine operating and maintenance considerations. GE power systems [Internal] report no. GER-3260K, 2004.