메뉴 건너뛰기




Volumn , Issue , 2008, Pages 1460-1463

Micro fluidic biosensor array for parallelized cell adhesion analysis during pathogenic infection

Author keywords

[No Author keywords available]

Indexed keywords

ADHESION ANALYSIS; BIOLOGICAL EXPERIMENTS; BIOSENSOR ARRAYS; CELL DISTRIBUTION; CELLULAR RESPONSE; FLOW DISTRIBUTION; IMPEDANCE ANALYZER; LIGHT MICROSCOPES; LOW COSTS; MADIN-DARBY CANINE KIDNEY CELLS; MICRO-FLUIDIC DEVICES; PATHOGENIC INFECTIONS; QUARTZ CRYSTAL RESONATOR; SENSOR INTERFACE ELECTRONICS; SENSOR SIGNALS; SENSOR SURFACES; SPREAD CELLS;

EID: 67649971156     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICSENS.2008.4716720     Document Type: Conference Paper
Times cited : (4)

References (10)
  • 1
    • 0037732638 scopus 로고    scopus 로고
    • Helicobacter pylori CagA protein targets the c-Met receptor and enhances the motogenic response
    • DOI 10.1083/jcb.200208039
    • Y. Churin, L. Al-Ghoul, O. Kepp, T. F. Meyer, W. Birchmeier and M. Naumann, "Helicobacter pylori CagA protein targets the c-Met receptor and enhances the motogenic response", The Journal of Cell Biology, vol.161 (2), pp. 249-255, 2003. (Pubitemid 36529844)
    • (2003) Journal of Cell Biology , vol.161 , Issue.2 , pp. 249-255
    • Churin, Y.1    Al-Ghoul, L.2    Kepp, O.3    Meyer, T.F.4    Birchmeier, W.5    Naumann, M.6
  • 2
    • 40149109180 scopus 로고    scopus 로고
    • Host-pathogen systems biology: Logical modelling of hepatocyte growth factor and Helicobacter pylori induced c-Met signal transduction
    • DOI 10.1186/1752-0509-2-4
    • R. Franke, M. Mueller, N. Wundrack, E.-D. Gilles, S. Klamt, T. Kähne and M. Naumann, "Host-pathogen systems biology: logical modelling of hepatocyte growth factor and Helicobacter pylori induced c-Met signal transduction", BioMed Central Systems Biology, vol.2:4, pp. 1-17, 2008. (Pubitemid 351325436)
    • (2008) BMC Systems Biology , vol.2 , pp. 4
    • Franke, R.1    Muller, M.2    Wundrack, N.3    Gilles, E.-D.4    Klamt, S.5    Kahne, T.6    Naumann, M.7
  • 3
    • 33644533528 scopus 로고    scopus 로고
    • Monitoring cell-cycle-related viscoelasticity by a quartz crystal microbalance
    • DOI 10.1063/1.2177647
    • A. Alessandrini, M.A. Croce, R. Tiozzo and P. Facci, "Monitoring cell-cycle-related viscoelasticity by a quartz crystal microbalance", Applied Physics Letters, vol. 88, pp. 083905-1-3, 2006. (Pubitemid 43297219)
    • (2006) Applied Physics Letters , vol.88 , Issue.8 , pp. 083905
    • Alessandrini, A.1    Croce, M.A.2    Tiozzo, R.3    Facci, P.4
  • 4
    • 0034045376 scopus 로고    scopus 로고
    • Analysis of the composite response of shear wave resonators to the attachment of mammalian cells
    • J. Wegener, J. Seebach, A. Janshoff, and H.-J. Galla, "Analysis of the Composite Response of Shear Wave Resonators to the Attachment of Mammalian Cells", Biophysical Journal, vol.78, pp.2821-2833, 2000. (Pubitemid 30396917)
    • (2000) Biophysical Journal , vol.78 , Issue.6 , pp. 2821-2833
    • Wegener, J.1    Seebach, J.2    Janshoff, A.3    Galla, H.-J.4
  • 5
    • 0032414252 scopus 로고    scopus 로고
    • Cell adhesion monitoring using a quartz crystal microbalance comparative analysis of different mammalian cell lines
    • DOI 10.1007/s002490050180
    • J. Wegener, A. Janshoff and H.-J. Galla, "Cell adhesion monitoring using a quartz crystal microbalance: comparative analysis of different mammalian cell lines", European Biophysical Journal, vol.28, pp. 26-37, 1998. (Pubitemid 29222680)
    • (1998) European Biophysics Journal , vol.28 , Issue.1 , pp. 26-37
    • Wegener, J.1    Janshoff, A.2    Galla, H.-J.3
  • 7
    • 48349124100 scopus 로고    scopus 로고
    • Micro fluidic biosensor system based on quartz crystal resonators for fast online adherent cell proliferation and stimulation analysis
    • T. Jacobs, A. Gomide, T. Kähne, A. Kienle, M. Naumann, P. Hauptmann, Micro Fluidic Biosensor System Based on Quartz Crystal Resonators for Fast Online Adherent Cell Proliferation and Stimulation Analysis, Proceedings of the 6th IEEE Sensors Conference, pp. 720-723, 2007.
    • (2007) Proceedings of the 6th IEEE Sensors Conference , pp. 720-723
    • Jacobs, T.1    Gomide, A.2    Kähne, T.3    Kienle, A.4    Naumann, M.5    Hauptmann, P.6
  • 8
    • 48349088738 scopus 로고    scopus 로고
    • The generalized acoustic load concept for QCM-mass sensitivity, viscoelasticity, and other phenomena
    • R. Lucklum and P. Hauptmann, "The generalized acoustic load concept for QCM-mass sensitivity, viscoelasticity, and other phenomena", Proceedings of the XVI Eurosensors Conference, pp. 41-44, 2002.
    • (2002) Proceedings of the XVI Eurosensors Conference , pp. 41-44
    • Lucklum, R.1    Hauptmann, P.2
  • 9
    • 0001455933 scopus 로고
    • Characterization of quartz crystal microbalance with simultaneous mass and liquid loading
    • S.J. Martin, V.E. Granstaff and G.C. Frye, "Characterization of quartz crystal microbalance with simultaneous mass and liquid loading", Analytical Chemistry, vol.63, pp. 2272-2281, 1991.
    • (1991) Analytical Chemistry , vol.63 , pp. 2272-2281
    • Martin, S.J.1    Granstaff, V.E.2    Frye, G.C.3
  • 10
    • 36048968570 scopus 로고    scopus 로고
    • Wideband impedance spectrum analyzer for process automation applications
    • DOI 10.1063/1.2785845
    • S. Doerner, T. Schneider and P. Hauptmann, "Wideband impedance spectrum analyzer for process automation applications", Review of Scientific Instruments, vol.78, paper 105101, 2007. (Pubitemid 350098123)
    • (2007) Review of Scientific Instruments , vol.78 , Issue.10 , pp. 105101
    • Doerner, S.1    Schneider, T.2    Hauptmann, P.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.