메뉴 건너뛰기




Volumn 120, Issue 7, 2009, Pages 1262-1272

Removing muscle and eye artifacts using blind source separation techniques in ictal EEG source imaging

Author keywords

Artifact removal; EEG source localization; Ictal SPECT

Indexed keywords

ADULT; ALGORITHM; ARTICLE; ARTIFACT REDUCTION; CLINICAL ARTICLE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; ELECTROENCEPHALOGRAM; EYE MOVEMENT; FEMALE; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; SEIZURE; SIGNAL NOISE RATIO; SINGLE PHOTON EMISSION COMPUTER TOMOGRAPHY;

EID: 67649866111     PISSN: 13882457     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clinph.2009.05.010     Document Type: Article
Times cited : (41)

References (29)
  • 1
    • 0030880914 scopus 로고    scopus 로고
    • Continuous source imaging of scalp ictal rhythms in temporal lobe epilepsy
    • Assaf B.A., and Ebersole J.S. Continuous source imaging of scalp ictal rhythms in temporal lobe epilepsy. Epilepsia 38 10 (1997) 1114-1123
    • (1997) Epilepsia , vol.38 , Issue.10 , pp. 1114-1123
    • Assaf, B.A.1    Ebersole, J.S.2
  • 4
    • 67649832407 scopus 로고    scopus 로고
    • Belouchrani A, Abed-Meraim K, Hua Y. Jacobi-like algorithms for joint block diagonalization: applications to source localization. In: Proceedings of the IEEE int. workshop on intelligent signal processing and communication systems (ISPACS) CD-ROM
    • Belouchrani A, Abed-Meraim K, Hua Y. Jacobi-like algorithms for joint block diagonalization: applications to source localization. In: Proceedings of the IEEE int. workshop on intelligent signal processing and communication systems (ISPACS) CD-ROM.
  • 5
    • 0026320416 scopus 로고
    • Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG
    • Berg P., and Scherg M. Dipole modelling of eye activity and its application to the removal of eye artefacts from the EEG and MEG. Clin Phys Physiol Meas 12 (1991) 49-54
    • (1991) Clin Phys Physiol Meas , vol.12 , pp. 49-54
    • Berg, P.1    Scherg, M.2
  • 7
    • 0028416938 scopus 로고
    • Independent component analysis, a new concept?
    • Comon P. Independent component analysis, a new concept?. Signal Process 36 3 (1994) 287-314
    • (1994) Signal Process , vol.36 , Issue.3 , pp. 287-314
    • Comon, P.1
  • 8
    • 33845880152 scopus 로고    scopus 로고
    • Canonical correlation analysis applied to remove muscle artifacts from the electroenceaphalogram
    • De Clercq W., Vergult A., Vanrumste B., Van Paesschen W., and Van Huffel S. Canonical correlation analysis applied to remove muscle artifacts from the electroenceaphalogram. IEEE Trans Biomed Eng 53 12 (2006) 2583-2587
    • (2006) IEEE Trans Biomed Eng , vol.53 , Issue.12 , pp. 2583-2587
    • De Clercq, W.1    Vergult, A.2    Vanrumste, B.3    Van Paesschen, W.4    Van Huffel, S.5
  • 9
    • 67649848416 scopus 로고    scopus 로고
    • Spatially constrained independent component analysis and applications in neuroscience
    • Tech. Rep. 09-02. Leuven, Belgium: ESAT, SCD, KULeuven; 2009
    • De Vos M. Spatially constrained independent component analysis and applications in neuroscience. Tech. Rep. 09-02. Leuven, Belgium: ESAT - SCD, KULeuven; 2009.
    • De Vos, M.1
  • 12
    • 33746817545 scopus 로고    scopus 로고
    • 3D source localization of interictal spikes in epilepsy patients with MRI lesions
    • Ding L., Worrell G.A., Lagerlund T.D., and He B. 3D source localization of interictal spikes in epilepsy patients with MRI lesions. Phys Med Biol 51 16 (2006) 4047-4062
    • (2006) Phys Med Biol , vol.51 , Issue.16 , pp. 4047-4062
    • Ding, L.1    Worrell, G.A.2    Lagerlund, T.D.3    He, B.4
  • 13
    • 0037213415 scopus 로고    scopus 로고
    • Improvement in the performance of automated spike detection using dipole source features for artefact rejection
    • Flanagan D., Agarwal R., Wang Y., and Gotman J. Improvement in the performance of automated spike detection using dipole source features for artefact rejection. Clin Neurophysiol 114 (2002) 38-49
    • (2002) Clin Neurophysiol , vol.114 , pp. 38-49
    • Flanagan, D.1    Agarwal, R.2    Wang, Y.3    Gotman, J.4
  • 15
    • 0038274527 scopus 로고    scopus 로고
    • In vivo measurement of the brain and skull resistivities using an eit-based method and realistic models for the head
    • Gonçalves S., de Munck J., Verbunt J., Bijma F., Heethaar R., Lopes da Silva F., et al. In vivo measurement of the brain and skull resistivities using an eit-based method and realistic models for the head. Biomed Eng, IEEE Trans 50 6 (2003) 754-767
    • (2003) Biomed Eng, IEEE Trans , vol.50 , Issue.6 , pp. 754-767
    • Gonçalves, S.1    de Munck, J.2    Verbunt, J.3    Bijma, F.4    Heethaar, R.5    Lopes da Silva, F.6
  • 16
    • 0041423684 scopus 로고    scopus 로고
    • Emg contamination of eeg: spectral and topographical characteristics
    • Goncharova I.I., McFarland D.J., Vaughan T.M., and Wolpaw J.R. Emg contamination of eeg: spectral and topographical characteristics. Clin Neurophysiol 114 9 (2003) 1580-1593
    • (2003) Clin Neurophysiol , vol.114 , Issue.9 , pp. 1580-1593
    • Goncharova, I.I.1    McFarland, D.J.2    Vaughan, T.M.3    Wolpaw, J.R.4
  • 18
    • 23744457106 scopus 로고    scopus 로고
    • A finite difference method with reciprocity used to incorporate anisotropy in electroencephalogram dipole source localization
    • Hallez H., Vanrumste B., Van Hese P., D'Asseler Y., Lemahieu I., and Van de Walle R. A finite difference method with reciprocity used to incorporate anisotropy in electroencephalogram dipole source localization. Phys Med Biol 50 (2005) 3787-3806
    • (2005) Phys Med Biol , vol.50 , pp. 3787-3806
    • Hallez, H.1    Vanrumste, B.2    Van Hese, P.3    D'Asseler, Y.4    Lemahieu, I.5    Van de Walle, R.6
  • 19
    • 0000107975 scopus 로고
    • Relations between two sets of variates
    • Hotelling H. Relations between two sets of variates. Biometrika 28 (1936) 321-377
    • (1936) Biometrika , vol.28 , pp. 321-377
    • Hotelling, H.1
  • 21
    • 33748514574 scopus 로고    scopus 로고
    • Ictal SPECT in neocortical epilepsies: clinical usefulness and factors affecting the pattern of hyperperfusion
    • Lee S., Lee S., Yun C., Lee H., Lee J., and Lee D. Ictal SPECT in neocortical epilepsies: clinical usefulness and factors affecting the pattern of hyperperfusion. Neuroradiology 48 (2006) 678-684
    • (2006) Neuroradiology , vol.48 , pp. 678-684
    • Lee, S.1    Lee, S.2    Yun, C.3    Lee, H.4    Lee, J.5    Lee, D.6
  • 22
    • 0033080008 scopus 로고    scopus 로고
    • Source localization using recursively applied and projected (RAP) MUSIC
    • Mosher J.C., and Leahy R.M. Source localization using recursively applied and projected (RAP) MUSIC. IEEE Trans Signal Process 47 (1999) 332-340
    • (1999) IEEE Trans Signal Process , vol.47 , pp. 332-340
    • Mosher, J.C.1    Leahy, R.M.2
  • 24
    • 0034762318 scopus 로고    scopus 로고
    • Partial signal space projection for artefact removal in MEG measurements: a theoretical analysis
    • Nolte G., and Hämäläinen M. Partial signal space projection for artefact removal in MEG measurements: a theoretical analysis. Phys Med Biol 46 (2001) 2873-2887
    • (2001) Phys Med Biol , vol.46 , pp. 2873-2887
    • Nolte, G.1    Hämäläinen, M.2
  • 25
    • 0031934337 scopus 로고    scopus 로고
    • Subtraction ictal SPECT co-registered to MRI improves clinical usefulness in localizing the surgical seizure focus
    • O'Brien T., So E., Mullan B., Hauser M., Brinkmann B., Bohnen N., et al. Subtraction ictal SPECT co-registered to MRI improves clinical usefulness in localizing the surgical seizure focus. Neurology 50 (1998) 445-454
    • (1998) Neurology , vol.50 , pp. 445-454
    • O'Brien, T.1    So, E.2    Mullan, B.3    Hauser, M.4    Brinkmann, B.5    Bohnen, N.6
  • 26
    • 38649116354 scopus 로고    scopus 로고
    • EEG source localization in focal epilepsy: where are we now?
    • Plummer C., Harvey S.A., and Cook M. EEG source localization in focal epilepsy: where are we now?. Epilepsia 49 (2008) 201-218
    • (2008) Epilepsia , vol.49 , pp. 201-218
    • Plummer, C.1    Harvey, S.A.2    Cook, M.3
  • 27
    • 18144428792 scopus 로고    scopus 로고
    • Removal of eye blinking artifact from the electro-encephalogram, incorporating a new constrained blind source separation algorithm
    • Shoker L., Sanei S., Wang W., and Chambers J.A. Removal of eye blinking artifact from the electro-encephalogram, incorporating a new constrained blind source separation algorithm. Med Biol Eng Comput 43 2 (2005) 290-295
    • (2005) Med Biol Eng Comput , vol.43 , Issue.2 , pp. 290-295
    • Shoker, L.1    Sanei, S.2    Wang, W.3    Chambers, J.A.4
  • 29
    • 34248578920 scopus 로고    scopus 로고
    • Improving the interpretation of ictal scalp EEG: BSS-CCA algorithm for muscle artifact removal
    • Vergult A., De Clercq W., Palmini A., Vanrumste B., Dupont P., Van Huffel S., et al. Improving the interpretation of ictal scalp EEG: BSS-CCA algorithm for muscle artifact removal. Epilepsia 48 (2007) 950-958
    • (2007) Epilepsia , vol.48 , pp. 950-958
    • Vergult, A.1    De Clercq, W.2    Palmini, A.3    Vanrumste, B.4    Dupont, P.5    Van Huffel, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.