-
1
-
-
0001340161
-
Importance of the hematocrit in interpretation of blood sugar
-
Dilon RS, Mawr B: Importance of the hematocrit in interpretation of blood sugar. Diabetes 1965;14:672-674.
-
(1965)
Diabetes
, vol.14
, pp. 672-674
-
-
Dilon, R.S.1
Mawr, B.2
-
2
-
-
0036948184
-
Report of the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus: Usefulness of venous blood method as a standardized comparative method for blood glucose measurement using devices]
-
Makoto T, Isao K, Katsuhiro K, Izumi T, Tadao H, Gen Y, Takashi K, Yoshiaki K, Hideshi K, Masamichi K, Tomohiko T, Eiichi M, Junko O, Zenji M, Motoaki S: [Report of the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus: usefulness of venous blood method as a standardized comparative method for blood glucose measurement using devices]. J Jpn Diabetes Soc. 2002;45:825-834.
-
(2002)
J Jpn Diabetes Soc
, vol.45
, pp. 825-834
-
-
Makoto, T.1
Isao, K.2
Katsuhiro, K.3
Izumi, T.4
Tadao, H.5
Gen, Y.6
Takashi, K.7
Yoshiaki, K.8
Hideshi, K.9
Masamichi, K.10
Tomohiko, T.11
Eiichi, M.12
Junko, O.13
Zenji, M.14
Motoaki, S.15
-
3
-
-
20344392145
-
Accuracy evaluation of the new glucometer with automated hematocrit measurement and correction
-
Rao LV, Jakubiak F, Sidwell JS, Winkelman JW, Snyder ML: Accuracy evaluation of the new glucometer with automated hematocrit measurement and correction. Clin Chim Acta 2005;356:178-183.
-
(2005)
Clin Chim Acta
, vol.356
, pp. 178-183
-
-
Rao, L.V.1
Jakubiak, F.2
Sidwell, J.S.3
Winkelman, J.W.4
Snyder, M.L.5
-
4
-
-
38949097440
-
Evaluation of the impact of hemat-ocrit and other interference on the accuracy of hospital-based glucose meters
-
Karon BS, Griesmann L, Scott R, Bryant SC, Dubois JA, Shirey TL, Presti S, Santrach PJ: Evaluation of the impact of hemat-ocrit and other interference on the accuracy of hospital-based glucose meters. Diabetes Technol Ther 2008;10:111-120.
-
(2008)
Diabetes Technol Ther
, vol.10
, pp. 111-120
-
-
Karon, B.S.1
Griesmann, L.2
Scott, R.3
Bryant, S.C.4
Dubois, J.A.5
Shirey, T.L.6
Presti, S.7
Santrach, P.J.8
-
5
-
-
54149111525
-
Risk of blood glucose measurements with handheld meters in anemia patient]
-
Yakushiji F, Yasuda M, Taniguchi K, Fujiki K, Oowada A, Akiyama N, Suzuki H, Jokyu R, Terayama Y, Shimojo M: [Risk of blood glucose measurements with handheld meters in anemia patient]. J Jpn Diabetes Soc 2008;51:837-843.
-
(2008)
J Jpn Diabetes Soc
, vol.51
, pp. 837-843
-
-
Yakushiji, F.1
Yasuda, M.2
Taniguchi, K.3
Fujiki, K.4
Oowada, A.5
Akiyama, N.6
Suzuki, H.7
Jokyu, R.8
Terayama, Y.9
Shimojo, M.10
-
6
-
-
38149122251
-
Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers
-
Man EA, Salinas J, Pidcoke HF, Wolf SE, Holcomb JB, Wade CE: Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers. J Trauma 2008;64:15-21.
-
(2008)
J Trauma
, vol.64
, pp. 15-21
-
-
Man, E.A.1
Salinas, J.2
Pidcoke, H.F.3
Wolf, S.E.4
Holcomb, J.B.5
Wade, C.E.6
-
7
-
-
0028262386
-
Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: Are they accurate?
-
Maser RE, Butler MA, DeCherney GS: Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med 1994;22:595-599.
-
(1994)
Crit Care Med
, vol.22
, pp. 595-599
-
-
Maser, R.E.1
Butler, M.A.2
DeCherney, G.S.3
-
8
-
-
33845326144
-
Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter
-
Balion C, Grey V, Ismaila A, Blatz S, Seidlitz W: Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter. BMC Pediatr 2006;6:28.
-
(2006)
BMC Pediatr
, vol.6
, pp. 28
-
-
Balion, C.1
Grey, V.2
Ismaila, A.3
Blatz, S.4
Seidlitz, W.5
-
9
-
-
0033849382
-
Effects of different he-matocrit levels on glucose measurements with handheld meters for point-of-care testing
-
Tang Z, Lee JH, Louie RF, Kost GJ: Effects of different he-matocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med 2000;124:1135-1140.
-
(2000)
Arch Pathol Lab Med
, vol.124
, pp. 1135-1140
-
-
Tang, Z.1
Lee, J.H.2
Louie, R.F.3
Kost, G.J.4
-
10
-
-
0024577154
-
Screening for hypoglycemia with plasma in neonatal blood of high hematocrit value
-
Kaplan M, Blondheim O, Alon I, Eylath U, Trestian S, Eidelman AI: Screening for hypoglycemia with plasma in neonatal blood of high hematocrit value. Crit Care Med 1989;17:279-282.
-
(1989)
Crit Care Med
, vol.17
, pp. 279-282
-
-
Kaplan, M.1
Blondheim, O.2
Alon, I.3
Eylath, U.4
Trestian, S.5
Eidelman, A.I.6
-
11
-
-
0033969498
-
The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit
-
Hussain K, Sharief N: The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit. Early Hum Dev 2000;57:111-121.
-
(2000)
Early Hum Dev
, vol.57
, pp. 111-121
-
-
Hussain, K.1
Sharief, N.2
-
12
-
-
67649833247
-
Blood component measuring method, sensor used therefor, and measuring instrument
-
Japanese Patent P2005-515983. June 16, 2005
-
Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. Japanese Patent P2005-515983. June 16, 2005.
-
-
-
Fujiwara, M.1
Sinnno, T.2
Ikeda, S.3
-
13
-
-
67649879821
-
-
Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. International Patent WO2005/054840. June 16, 2005.
-
Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. International Patent WO2005/054840. June 16, 2005.
-
-
-
-
14
-
-
44249100012
-
The technology behind glucose meters: Test strips
-
Hönes J, Müller P, Surridge N: The technology behind glucose meters: test strips. Diabetes Technol Ther 2008; 10(Suppl 1):S-10-S-26.
-
(2008)
Diabetes Technol Ther
, vol.10
, Issue.SUPPL. 1
-
-
Hönes, J.1
Müller, P.2
Surridge, N.3
|