Glutest neo super-a new handheld blood glucose meter-corrects for the effects of the hematocrit values in both hematocrit-adjusted samples and samples obtained from anemic patients

Author keywords

[No Author keywords available]

Indexed keywords

GLUCOSE;

EID: 67649841975     PISSN: 15209156     EISSN: None     Source Type: Journal    
DOI: 10.1089/dia.2008.0095     Document Type: Article
Times cited : (8)

References (14)
  • 1
    • 0001340161 scopus 로고
    • Importance of the hematocrit in interpretation of blood sugar
    • Dilon RS, Mawr B: Importance of the hematocrit in interpretation of blood sugar. Diabetes 1965;14:672-674.
    • (1965) Diabetes , vol.14 , pp. 672-674
    • Dilon, R.S.1    Mawr, B.2
  • 3
    • 20344392145 scopus 로고    scopus 로고
    • Accuracy evaluation of the new glucometer with automated hematocrit measurement and correction
    • Rao LV, Jakubiak F, Sidwell JS, Winkelman JW, Snyder ML: Accuracy evaluation of the new glucometer with automated hematocrit measurement and correction. Clin Chim Acta 2005;356:178-183.
    • (2005) Clin Chim Acta , vol.356 , pp. 178-183
    • Rao, L.V.1    Jakubiak, F.2    Sidwell, J.S.3    Winkelman, J.W.4    Snyder, M.L.5
  • 6
    • 38149122251 scopus 로고    scopus 로고
    • Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers
    • Man EA, Salinas J, Pidcoke HF, Wolf SE, Holcomb JB, Wade CE: Error rates resulting from anemia can be corrected in multiple commonly used point-of-care glucometers. J Trauma 2008;64:15-21.
    • (2008) J Trauma , vol.64 , pp. 15-21
    • Man, E.A.1    Salinas, J.2    Pidcoke, H.F.3    Wolf, S.E.4    Holcomb, J.B.5    Wade, C.E.6
  • 7
    • 0028262386 scopus 로고
    • Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: Are they accurate?
    • Maser RE, Butler MA, DeCherney GS: Use of arterial blood with bedside glucose reflectance meters in an intensive care unit: are they accurate? Crit Care Med 1994;22:595-599.
    • (1994) Crit Care Med , vol.22 , pp. 595-599
    • Maser, R.E.1    Butler, M.A.2    DeCherney, G.S.3
  • 8
    • 33845326144 scopus 로고    scopus 로고
    • Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter
    • Balion C, Grey V, Ismaila A, Blatz S, Seidlitz W: Screening for hypoglycemia at the bedside in the neonatal intensive care unit (NICU) with the Abbott PCx glucose meter. BMC Pediatr 2006;6:28.
    • (2006) BMC Pediatr , vol.6 , pp. 28
    • Balion, C.1    Grey, V.2    Ismaila, A.3    Blatz, S.4    Seidlitz, W.5
  • 9
    • 0033849382 scopus 로고    scopus 로고
    • Effects of different he-matocrit levels on glucose measurements with handheld meters for point-of-care testing
    • Tang Z, Lee JH, Louie RF, Kost GJ: Effects of different he-matocrit levels on glucose measurements with handheld meters for point-of-care testing. Arch Pathol Lab Med 2000;124:1135-1140.
    • (2000) Arch Pathol Lab Med , vol.124 , pp. 1135-1140
    • Tang, Z.1    Lee, J.H.2    Louie, R.F.3    Kost, G.J.4
  • 11
    • 0033969498 scopus 로고    scopus 로고
    • The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit
    • Hussain K, Sharief N: The inaccuracy of venous and capillary blood glucose measurement using reagent strips in the newborn period and the effect of haematocrit. Early Hum Dev 2000;57:111-121.
    • (2000) Early Hum Dev , vol.57 , pp. 111-121
    • Hussain, K.1    Sharief, N.2
  • 12
    • 67649833247 scopus 로고    scopus 로고
    • Blood component measuring method, sensor used therefor, and measuring instrument
    • Japanese Patent P2005-515983. June 16, 2005
    • Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. Japanese Patent P2005-515983. June 16, 2005.
    • Fujiwara, M.1    Sinnno, T.2    Ikeda, S.3
  • 13
    • 67649879821 scopus 로고    scopus 로고
    • Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. International Patent WO2005/054840. June 16, 2005.
    • Fujiwara M, Sinnno T, Ikeda S: Blood component measuring method, sensor used therefor, and measuring instrument. International Patent WO2005/054840. June 16, 2005.
  • 14
    • 44249100012 scopus 로고    scopus 로고
    • The technology behind glucose meters: Test strips
    • Hönes J, Müller P, Surridge N: The technology behind glucose meters: test strips. Diabetes Technol Ther 2008; 10(Suppl 1):S-10-S-26.
    • (2008) Diabetes Technol Ther , vol.10 , Issue.SUPPL. 1
    • Hönes, J.1    Müller, P.2    Surridge, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.