Volumn 26, Issue 7, 2009, Pages 714-721

Glucose monitoring by microdialysis: Performance in a multicentre study

Author keywords

Accuracy; Continuous glucose monitoring; Microdialysis; Variability

Indexed keywords

ACCURACY; ADULT; ANALYTICAL EQUIPMENT; ARTICLE; BLOOD GLUCOSE MONITORING; BODY MASS; CALIBRATION; CLINICAL ARTICLE; DATA ANALYSIS; DEMOGRAPHY; DISEASE DURATION; EXPERIMENTAL STUDY; FEMALE; GLUCOSE CLAMP TECHNIQUE; HUMAN; INSULIN DEPENDENT DIABETES MELLITUS; MALE; MICRODIALYSIS; MULTICENTER STUDY; NON INSULIN DEPENDENT DIABETES MELLITUS; RELIABILITY; STATISTICS;

EID: 67649803122     PISSN: 07423071     EISSN: 14645491     Source Type: Journal    
DOI: 10.1111/j.1464-5491.2009.02750.x     Document Type: Article
Times cited : (19)

References (13)
  • 1
    • 0042553279 scopus 로고
    • Smoothing + differentiation of data by simplified least squares procedures
    • Savitzky A, Golay MJE. Smoothing + differentiation of data by simplified least squares procedures. Anal Chem 1964 36 : 1627.
    • (1964) Anal Chem , vol.36 , pp. 1627
    • Savitzky, A.1    Golay, M.J.E.2
  • 2
    • 67649776953 scopus 로고    scopus 로고
    • The Clinical Research Tool: A high-performance microdialysis-based system for reliably measuring ISF glucose concentrations
    • in press.
    • Orvick G, Hansjek M, Gillen R, Guenther A, Hochmuth G, Kamecke U et al. The Clinical Research Tool: a high-performance microdialysis-based system for reliably measuring ISF glucose concentrations. J Diabetes Sci Technol, in press.
    • J Diabetes Sci Technol
    • Orvick, G.1    Hansjek, M.2    Gillen, R.3    Guenther, A.4    Hochmuth, G.5    Kamecke, U.6
  • 4
    • 0023205574 scopus 로고
    • Evaluating clinical accuracy of systems for self-monitoring of blood glucose
    • Clarke WL, Cox D, Gonder-Frederick LA, Carter W, Pohl SL. Evaluating clinical accuracy of systems for self-monitoring of blood glucose. Diabetes Care 1987 10 : 622 628. (Pubitemid 17158937)
    • (1987) Diabetes Care , vol.10 , Issue.5 , pp. 622-628
    • Clarke, W.L.1    Cox, D.2    Gonder-Frederick, L.A.3    Carter, W.4    Pohl, S.L.5
  • 6
    • 33748436855 scopus 로고    scopus 로고
    • Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans
    • DOI 10.1089/dia.2006.8.326
    • Rossetti P, Porcellati F, Fanelli CG, Bolli GB. Evaluation of the accuracy of a microdialysis-based glucose sensor during insulin-induced hypoglycemia, its recovery, and post-hypoglycemic hyperglycemia in humans. Diabetes Technol Ther 2006 8 : 326 337. (Pubitemid 46100527)
    • (2006) Diabetes Technology and Therapeutics , vol.8 , Issue.3 , pp. 326-337
    • Rossetti, P.1    Porcellati, F.2    Fanelli, G.G.3    Bolli, G.B.4
  • 8
    • 33845475479 scopus 로고    scopus 로고
    • 1c values: Safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor
    • DOI 10.2337/dc06-1361
    • Garg S, Jovanovic L. Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor. Diabetes Care 2006 29 : 2644 2649. (Pubitemid 44912192)
    • (2006) Diabetes Care , vol.29 , Issue.12 , pp. 2644-2649
    • Garg, S.1    Jovanovic, L.2
  • 9
    • 33644875792 scopus 로고    scopus 로고
    • Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: A randomized controlled trial
    • Garg S, Zisser H, Schwartz S, Bailey T, Kaplan R, Ellis S et al. Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. Diabetes Care 2006 29 : 44 50. (Pubitemid 44033429)
    • (2006) Diabetes Care , vol.29 , Issue.1 , pp. 44-50
    • Garg, S.1    Zisser, H.2    Schwartz, S.3    Bailey, T.4    Kaplan, R.5    Ellis, S.6    Jovanovic, L.7
  • 10
    • 48649110903 scopus 로고    scopus 로고
    • Comparison of the numerical and clinical accuracy of four continuous glucose monitors
    • Kovatchev B, Anderson S, Heinemann L, Clarke W. Comparison of the numerical and clinical accuracy of four continuous glucose monitors. Diabetes Care 2008 31 : 1160 1164.
    • (2008) Diabetes Care , vol.31 , pp. 1160-1164
    • Kovatchev, B.1    Anderson, S.2    Heinemann, L.3    Clarke, W.4
  • 11
    • 34247600583 scopus 로고    scopus 로고
    • Accuracy of the 5-day FreeStyle Navigator Continuous Glucose Monitoring System: Comparison with frequent laboratory reference measurements
    • DOI 10.2337/dc06-1602
    • Weinstein RL, Bugler JR, Schwartz SL, Peyser TA, Brazg RL, McGarraugh GV. Accuracy of the 5-day freestyle navigator continuous glucose monitoring system - comparison with frequent laboratory reference measurements. Diabetes Care 2007 30 : 1125 1130. (Pubitemid 46684636)
    • (2007) Diabetes Care , vol.30 , Issue.5 , pp. 1125-1130
    • Weinstein, R.L.1    Schwartz, S.L.2    Brazg, R.L.3    Bugler, J.R.4    Peyser, T.A.5    McGarraugh, G.V.6
  • 12
  • 13
    • 58149389636 scopus 로고    scopus 로고
    • Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): Is CGM ready for real time?
    • Mazze RS, Strock E, Borgman S, Wesley D, Stout P, Racchini J. Evaluating the accuracy, reliability, and clinical applicability of continuous glucose monitoring (CGM): is CGM ready for real time? Diabetes Technol Ther 2009 11 : 11 18.
    • (2009) Diabetes Technol Ther , vol.11 , pp. 11-18
    • Mazze, R.S.1    Strock, E.2    Borgman, S.3    Wesley, D.4    Stout, P.5    Racchini, J.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.