메뉴 건너뛰기




Volumn 12, Issue 2, 2009, Pages

Mitroflow bioprosthesis stent deformation: A rare cause of early prosthetic stenosis

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; ANGIOCARDIOGRAPHY; ANTICOAGULANT THERAPY; AORTA VALVE REPLACEMENT; AORTA VALVE STENOSIS; ARTICLE; CASE REPORT; CHRONIC OBSTRUCTIVE LUNG DISEASE; CLINICAL EVALUATION; COMORBIDITY; CORONARY ARTERY OBSTRUCTION; DACRON VASCULAR PROSTHESIS; DYSPNEA; ECHOCARDIOGRAPHY; FOLLOW UP; HEART EJECTION FRACTION; HOSPITAL DISCHARGE; HUMAN; MALE; NON INSULIN DEPENDENT DIABETES MELLITUS; PRIORITY JOURNAL; PROSTHETIC VALVE DYSFUNCTION; SMOKING; TRANSTHORACIC ECHOCARDIOGRAPHY; BIOPROSTHESIS; DEVICE REMOVAL; HEART VALVE PROSTHESIS; MIDDLE AGED; PROSTHESIS FAILURE; STENT;

EID: 67649672073     PISSN: 10983511     EISSN: 15226662     Source Type: Journal    
DOI: 10.1532/HSF98.20081144     Document Type: Article
Times cited : (3)

References (8)
  • 2
    • 33646168073 scopus 로고    scopus 로고
    • Small aortic annulus: The hydrodinamic performances of 5 commercially available tissue valves
    • Gerosa G, Tarzia V, Rizzoli G, Bottio T. 2006. Small aortic annulus: the hydrodinamic performances of 5 commercially available tissue valves. J Thorac Cardiovasc Surg 131:1058-64.
    • (2006) J Thorac Cardiovasc Surg , vol.131 , pp. 1058-1064
    • Gerosa, G.1    Tarzia, V.2    Rizzoli, G.3    Bottio, T.4
  • 3
    • 0033955674 scopus 로고    scopus 로고
    • Mitroflow pericardial valve prosthesis in the aortic position: An analysis of long-term outcome and prognostic factors
    • Minami K, Boethig D, Mirow N, et al. 2000. Mitroflow pericardial valve prosthesis in the aortic position: an analysis of long-term outcome and prognostic factors. J Heart Valve Dis 9:112-22.
    • (2000) J Heart Valve Dis , vol.9 , pp. 112-122
    • Minami, K.1    Boethig, D.2    Mirow, N.3
  • 5
    • 33645577229 scopus 로고    scopus 로고
    • Long-term outcome of the Mitroflow pericardial bioprosthesis in the elderly after aortic valve replacement
    • Sjögren J, Gudbjartsson T, Thulin LI. 2006. Long-term outcome of the Mitroflow pericardial bioprosthesis in the elderly after aortic valve replacement. J Heart Valve Dis 15:197-202.
    • (2006) J Heart Valve Dis , vol.15 , pp. 197-202
    • Sjögren, J.1    Gudbjartsson, T.2    Thulin, L.I.3
  • 6
    • 0034461530 scopus 로고    scopus 로고
    • Mitroflow pericardial bioprosthesis in the aortic position. Low incidence of structural valve deterioration in elderly patients during an 11-year follow-up
    • Thulin LI, Thilén UJ, Kymle KA. 2000. Mitroflow pericardial bioprosthesis in the aortic position. Low incidence of structural valve deterioration in elderly patients during an 11-year follow-up. Scand Cardiovasc J 34:192-6.
    • (2000) Scand Cardiovasc J , vol.34 , pp. 192-196
    • Thulin, L.I.1    Thilén, U.J.2    Kymle, K.A.3
  • 7
    • 0033504502 scopus 로고    scopus 로고
    • Aortic valve replacement with Mitroflow bioprosthesis in elderly patients with small aortic annulus
    • Totaro P, Fellini M, Zogno M, Borghetti V, Coletti G, Lorusso R. 2000. Aortic valve replacement with Mitroflow bioprosthesis in elderly patients with small aortic annulus. Cor Europaeum 8:71-75.
    • (2000) Cor Europaeum , vol.8 , pp. 71-75
    • Totaro, P.1    Fellini, M.2    Zogno, M.3    Borghetti, V.4    Coletti, G.5    Lorusso, R.6
  • 8
    • 24344498325 scopus 로고    scopus 로고
    • Seventeen-year clinical results of 1,037 Mitroflow pericardial heart valve prostheses in the aortic position
    • discussion 179-80
    • Yankah CA, Schubel J, Buz S, Siniawski H, Hetzer R. 2005. Seventeen-year clinical results of 1,037 Mitroflow pericardial heart valve prostheses in the aortic position. J Heart Valve Dis 14:172-9, discussion 179-80.
    • (2005) J Heart Valve Dis , vol.14 , pp. 172-179
    • Yankah, C.A.1    Schubel, J.2    Buz, S.3    Siniawski, H.4    Hetzer, R.5