-
1
-
-
0024388994
-
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system
-
0300-8827.
-
G. Selvik, " Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.," Acta Orthop. Scand. Suppl. 0300-8827 232, 1-51 (1989).
-
(1989)
Acta Orthop. Scand. Suppl.
, vol.232
, pp. 1-51
-
-
Selvik, G.1
-
2
-
-
24144447269
-
Guidelines for standardization of radiostereometry (RSA) of implants
-
1745-3674
-
E. R. Valstar, R. Gill, L. Ryd, G. Flivik, N. Börlin, and J. Kärrholm, " Guidelines for standardization of radiostereometry (RSA) of implants.," Acta Orthop. 76, 563-572 (2005). 1745-3674
-
(2005)
Acta Orthop.
, vol.76
, pp. 563-572
-
-
Valstar, E.R.1
Gill, R.2
Ryd, L.3
Flivik, G.4
Börlin, N.5
Kärrholm, J.6
-
3
-
-
0036135893
-
The precision of radiostereometric measurements. Manual vs. digital measurements
-
0021-9290,. 10.1016/S0021-9290(01)00162-2
-
N. Börlin, T. Thien, and J. Kärrholm, " The precision of radiostereometric measurements. Manual vs. digital measurements.," J. Biomech. 0021-9290 35, 69-79 (2002). 10.1016/S0021-9290(01)00162-2
-
(2002)
J. Biomech.
, vol.35
, pp. 69-79
-
-
Börlin, N.1
Thien, T.2
Kärrholm, J.3
-
4
-
-
0033817096
-
Digital automated RSA compared to manually operated RSA
-
0021-9290,. 10.1016/S0021-9290(00)00138-X
-
E. R. Valstar, H. A. Vrooman, S. Toksvig-Larsen, L. Ryd, and R. G. Nelissen, " Digital automated RSA compared to manually operated RSA.," J. Biomech. 0021-9290 33, 1593-1599 (2000). 10.1016/S0021-9290(00)00138-X
-
(2000)
J. Biomech.
, vol.33
, pp. 1593-1599
-
-
Valstar, E.R.1
Vrooman, H.A.2
Toksvig-Larsen, S.3
Ryd, L.4
Nelissen, R.G.5
-
5
-
-
0031239989
-
Error propagation for relative motion determined from marker positions
-
0021-9290,. 10.1016/S0021-9290(97)00054-7
-
X. Yuan, L. Ryd, and L. Blankevoort, " Error propagation for relative motion determined from marker positions.," J. Biomech. 0021-9290 30, 989-992 (1997). 10.1016/S0021-9290(97)00054-7
-
(1997)
J. Biomech.
, vol.30
, pp. 989-992
-
-
Yuan, X.1
Ryd, L.2
Blankevoort, L.3
-
6
-
-
0033430134
-
Correction for geometric image distortion in the x-ray imaging chain: Local technique versus global technique
-
0094-2405,. 10.1118/1.598800
-
E. Gronenschild, " Correction for geometric image distortion in the x-ray imaging chain: Local technique versus global technique.," Med. Phys. 0094-2405 26, 2602-2616 (1999). 10.1118/1.598800
-
(1999)
Med. Phys.
, vol.26
, pp. 2602-2616
-
-
Gronenschild, E.1
-
7
-
-
0037321795
-
A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images
-
0094-2405,. 10.1118/1.1538228
-
S. Fantozzi, A. Cappello, and A. Leardini, " A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images.," Med. Phys. 0094-2405 30, 124-131 (2003). 10.1118/1.1538228
-
(2003)
Med. Phys.
, vol.30
, pp. 124-131
-
-
Fantozzi, S.1
Cappello, A.2
Leardini, A.3
-
8
-
-
12844265930
-
Correction of XRII geometric distortion using a liquid-filled grid and image subtraction
-
0094-2405,. 10.1118/1.1827751
-
D. W. Holdsworth, S. I. Pollmann, H. N. Nikolov, and R. Fahrig, " Correction of XRII geometric distortion using a liquid-filled grid and image subtraction.," Med. Phys. 0094-2405 32, 55-64 (2005). 10.1118/1.1827751
-
(2005)
Med. Phys.
, vol.32
, pp. 55-64
-
-
Holdsworth, D.W.1
Pollmann, S.I.2
Nikolov, H.N.3
Fahrig, R.4
-
9
-
-
39649093670
-
Development of an RSA calibration system with improved accuracy and precision
-
0021-9290,. 10.1016/j.jbiomech.2007.11.012
-
R. Cai, X. Yuan, C. Rorabeck, R. B. Bourne, and D. W. Holdsworth, " Development of an RSA calibration system with improved accuracy and precision.," J. Biomech. 0021-9290 41, 907-911 (2008). 10.1016/j.jbiomech. 2007.11.012
-
(2008)
J. Biomech.
, vol.41
, pp. 907-911
-
-
Cai, R.1
Yuan, X.2
Rorabeck, C.3
Bourne, R.B.4
Holdsworth, D.W.5
-
10
-
-
0034444153
-
3D coordinate computation by RSA under non-standard conditions
-
1557-170X
-
R. Soavi, M. Motta, A. Visani, L. Bragonzoni, and I. Loreti, " 3D coordinate computation by RSA under non-standard conditions.," Conf. Proc. IEEE Eng. Med. Biol. Soc. 1, 570-572 (2000). 1557-170X
-
(2000)
Conf. Proc. IEEE Eng. Med. Biol. Soc.
, vol.1
, pp. 570-572
-
-
Soavi, R.1
Motta, M.2
Visani, A.3
Bragonzoni, L.4
Loreti, I.5
-
11
-
-
1042303579
-
Three-dimensional point localisation in low-dose x-ray images using stereo-photogrammetry
-
0140-0118,. 10.1007/BF02351009
-
T. S. Douglas, C. L. Vaughan, and S. M. Wynne, " Three-dimensional point localisation in low-dose x-ray images using stereo-photogrammetry.," Med. Biol. Eng. Comput. 0140-0118 42, 37-43 (2004). 10.1007/BF02351009
-
(2004)
Med. Biol. Eng. Comput.
, vol.42
, pp. 37-43
-
-
Douglas, T.S.1
Vaughan, C.L.2
Wynne, S.M.3
-
12
-
-
0032849383
-
Super-global distortion correction for a rotational C-arm x-ray image intensifier
-
0094-2405,. 10.1118/1.598684
-
R. R. Liu, S. Rudin, and D. R. Bednarek, " Super-global distortion correction for a rotational C-arm x-ray image intensifier.," Med. Phys. 0094-2405 26, 1802-1810 (1999). 10.1118/1.598684
-
(1999)
Med. Phys.
, vol.26
, pp. 1802-1810
-
-
Liu, R.R.1
Rudin, S.2
Bednarek, D.R.3
-
13
-
-
0030742408
-
Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion
-
0094-2405,. 10.1118/1.598013
-
R. Fahrig, M. Moreau, and D. W. Holdsworth, " Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion.," Med. Phys. 0094-2405 24, 1097-1106 (1997). 10.1118/1.598013
-
(1997)
Med. Phys.
, vol.24
, pp. 1097-1106
-
-
Fahrig, R.1
Moreau, M.2
Holdsworth, D.W.3
-
14
-
-
0034132382
-
Accurate accuracy assessment: Review of basic principles
-
0001-6470,. 10.1080/00016470052944017
-
J. Ranstam, L. Ryd, and I. Onsten, " Accurate accuracy assessment: Review of basic principles.," Acta Orthop. Scand. 0001-6470 71, 106-108 (2000). 10.1080/00016470052944017
-
(2000)
Acta Orthop. Scand.
, vol.71
, pp. 106-108
-
-
Ranstam, J.1
Ryd, L.2
Onsten, I.3
-
15
-
-
0036316748
-
Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model
-
0736-0266,. 10.1016/S0736-0266(01)00171-1
-
C. R. Bragdon, H. Malchau, X. Yuan, R. Perinchief, J. Karrholm, N. Börlin, D. M. Estok, and W. H. Harris, " Experimental assessment of precision and accuracy of radiostereometric analysis for the determination of polyethylene wear in a total hip replacement model.," J. Orthop. Res. 0736-0266 20, 688-695 (2002). 10.1016/S0736-0266(01)00171-1
-
(2002)
J. Orthop. Res.
, vol.20
, pp. 688-695
-
-
Bragdon, C.R.1
Malchau, H.2
Yuan, X.3
Perinchief, R.4
Karrholm, J.5
Börlin, N.6
Estok, D.M.7
Harris, W.H.8
-
16
-
-
0035215807
-
Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models
-
0736-0266,. 10.1016/S0736-0266(01)00039-0
-
I. Önsten, A. Berzins, S. Shott, and D. R. Sumner, " Accuracy and precision of radiostereometric analysis in the measurement of THR femoral component translations: Human and canine in vitro models.," J. Orthop. Res. 0736-0266 19, 1162-1167 (2001). 10.1016/S0736-0266(01)00039-0
-
(2001)
J. Orthop. Res.
, vol.19
, pp. 1162-1167
-
-
Önsten, I.1
Berzins, A.2
Shott, S.3
Sumner, D.R.4
-
17
-
-
0032071198
-
Fast and accurate automated measurements in digitized stereophotogrammetric radiographs
-
0021-9290,. 10.1016/S0021-9290(98)00025-6
-
H. A. Vrooman, E. R. Valstar, G. -J. Brand, D. R. Admiraal, P. M. Rozing, and J. H. C. Reiber, " Fast and accurate automated measurements in digitized stereophotogrammetric radiographs.," J. Biomech. 0021-9290 31, 491-498 (1998). 10.1016/S0021-9290(98)00025-6
-
(1998)
J. Biomech.
, vol.31
, pp. 491-498
-
-
Vrooman, H.A.1
Valstar, E.R.2
Brand, G.-J.3
Admiraal, D.R.4
Rozing, P.M.5
Reiber, J.H.C.6
|