메뉴 건너뛰기




Volumn 74, Issue 4, 2009, Pages 1266-1275

Effects of Respiration-Induced Density Variations on Dose Distributions in Radiotherapy of Lung Cancer

Author keywords

4D dose accumulation; 4D treatment planning; Deformable image registration; Lung cancer; Mid ventilation

Indexed keywords

4D DOSE ACCUMULATION; 4D TREATMENT PLANNING; DEFORMABLE IMAGE REGISTRATION; LUNG CANCER; MID-VENTILATION;

EID: 67649525965     PISSN: 03603016     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrobp.2009.02.073     Document Type: Article
Times cited : (45)

References (19)
  • 1
    • 23944489820 scopus 로고    scopus 로고
    • Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications
    • Rosu M., Chetty I.J., Balter J.M., et al. Dose reconstruction in deforming lung anatomy: Dose grid size effects and clinical implications. Med Phys 32 (2005) 2487-2495
    • (2005) Med Phys , vol.32 , pp. 2487-2495
    • Rosu, M.1    Chetty, I.J.2    Balter, J.M.3
  • 2
    • 33748576243 scopus 로고    scopus 로고
    • Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system
    • Keall P.J., Cattell H., Pokhrel D., et al. Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system. Int J Radiat Oncol Biol Phys 65 (2006) 1579-1584
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1579-1584
    • Keall, P.J.1    Cattell, H.2    Pokhrel, D.3
  • 3
    • 41449087578 scopus 로고    scopus 로고
    • Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study
    • Nioutsikou E., Seppenwoolde Y., Symonds-Tayler J.R., et al. Dosimetric investigation of lung tumor motion compensation with a robotic respiratory tracking system: An experimental study. Med Phys 35 (2008) 1232-1240
    • (2008) Med Phys , vol.35 , pp. 1232-1240
    • Nioutsikou, E.1    Seppenwoolde, Y.2    Symonds-Tayler, J.R.3
  • 4
    • 33750548857 scopus 로고    scopus 로고
    • Clinical implementation of target tracking by breathing synchronized delivery
    • Tewatia D., Zhang T., Tome W., et al. Clinical implementation of target tracking by breathing synchronized delivery. Med Phys 33 (2006) 4330-4336
    • (2006) Med Phys , vol.33 , pp. 4330-4336
    • Tewatia, D.1    Zhang, T.2    Tome, W.3
  • 5
    • 0037422708 scopus 로고    scopus 로고
    • Acquiring a four-dimensional computed tomography dataset using an external respiratory signal
    • Vedam S.S., Keall P.J., Kini V.R., et al. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. Phys Med Biol 48 (2003) 45-62
    • (2003) Phys Med Biol , vol.48 , pp. 45-62
    • Vedam, S.S.1    Keall, P.J.2    Kini, V.R.3
  • 6
    • 67649463319 scopus 로고    scopus 로고
    • Mid-ventilation Determination with Automatic Four-dimensional Rigid Grey-value Registration on Respiration-correlated Computed Tomography Scans with Moving Lung Tumours
    • Toronto, ON, Canada, June 3
    • Nijkamp J, Wolthaus JWH, Sonke JJ, et al. Mid-ventilation Determination with Automatic Four-dimensional Rigid Grey-value Registration on Respiration-correlated Computed Tomography Scans with Moving Lung Tumours. Proceedings of the XVth ICCR, Toronto, ON, Canada, June 3, 2007.
    • (2007) Proceedings of the XVth ICCR
    • Nijkamp, J.1    Wolthaus, J.W.H.2    Sonke, J.J.3
  • 7
    • 33644549665 scopus 로고    scopus 로고
    • Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue
    • Brock K.K., Dawson L.A., Sharpe M.B., et al. Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue. Int J Radiat Oncol Biol Phys 64 (2006) 1245-1254
    • (2006) Int J Radiat Oncol Biol Phys , vol.64 , pp. 1245-1254
    • Brock, K.K.1    Dawson, L.A.2    Sharpe, M.B.3
  • 8
    • 50449101752 scopus 로고    scopus 로고
    • Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration
    • Wolthaus J.W.H., Sonke J.J., Herk M., et al. Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration. Med Phys 35 (2008) 3998-4011
    • (2008) Med Phys , vol.35 , pp. 3998-4011
    • Wolthaus, J.W.H.1    Sonke, J.J.2    Herk, M.3
  • 9
    • 33748536386 scopus 로고    scopus 로고
    • Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients
    • Wolthaus J.W., Schneider C., Sonke J.J., et al. Mid-ventilation CT scan construction from four-dimensional respiration-correlated CT scans for radiotherapy planning of lung cancer patients. Int J Radiat Oncol Biol Phys 65 (2006) 1560-1571
    • (2006) Int J Radiat Oncol Biol Phys , vol.65 , pp. 1560-1571
    • Wolthaus, J.W.1    Schneider, C.2    Sonke, J.J.3
  • 10
    • 17844385102 scopus 로고    scopus 로고
    • Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking
    • Keall P.J., Joshi S., Vedam S.S., et al. Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking. Med Phys 32 (2005) 942-951
    • (2005) Med Phys , vol.32 , pp. 942-951
    • Keall, P.J.1    Joshi, S.2    Vedam, S.S.3
  • 11
    • 0036534905 scopus 로고    scopus 로고
    • Inclusion of geometric uncertainties in treatment plan evaluation
    • Van Herk M., Remeijer P., and Lebesque J.V. Inclusion of geometric uncertainties in treatment plan evaluation. Int J Radiat Oncol Biol Phys 52 (2002) 1407-1422
    • (2002) Int J Radiat Oncol Biol Phys , vol.52 , pp. 1407-1422
    • Van Herk, M.1    Remeijer, P.2    Lebesque, J.V.3
  • 12
    • 58149110802 scopus 로고    scopus 로고
    • To ensure that target volumes are not underirradiated when respiratory motion may affect the dose distribution, 4D dose calculations should be performed
    • Starkschall G., Gibbons J.P., and Orton C.G. To ensure that target volumes are not underirradiated when respiratory motion may affect the dose distribution, 4D dose calculations should be performed. Med Phys 36 (2009) 1-3
    • (2009) Med Phys , vol.36 , pp. 1-3
    • Starkschall, G.1    Gibbons, J.P.2    Orton, C.G.3
  • 13
    • 38349112015 scopus 로고    scopus 로고
    • Variability of four-dimensional computed tomography patient models
    • Sonke J.J., Lebesque J., and van Herk M. Variability of four-dimensional computed tomography patient models. Int J Radiat Oncol Biol Phys 70 (2008) 590-598
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 590-598
    • Sonke, J.J.1    Lebesque, J.2    van Herk, M.3
  • 14
    • 67349247094 scopus 로고    scopus 로고
    • Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance
    • Sonke J.J., Rossi M., Wolthaus J., et al. Frameless stereotactic body radiotherapy for lung cancer using four-dimensional cone beam CT guidance. Int J Radiat Oncol Biol Phys 74 (2009) 567-574
    • (2009) Int J Radiat Oncol Biol Phys , vol.74 , pp. 567-574
    • Sonke, J.J.1    Rossi, M.2    Wolthaus, J.3
  • 15
    • 33748297735 scopus 로고    scopus 로고
    • Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations
    • Vanderstraeten B., Reynaert N., Paelinck L., et al. Accuracy of patient dose calculation for lung IMRT: A comparison of Monte Carlo, convolution/superposition, and pencil beam computations. Med Phys 33 (2006) 3149-3158
    • (2006) Med Phys , vol.33 , pp. 3149-3158
    • Vanderstraeten, B.1    Reynaert, N.2    Paelinck, L.3
  • 16
    • 38349073449 scopus 로고    scopus 로고
    • Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume
    • Admiraal M.A., Schuring D., and Hurkmans C.W. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume. Radiother Oncol 86 (2008) 55-60
    • (2008) Radiother Oncol , vol.86 , pp. 55-60
    • Admiraal, M.A.1    Schuring, D.2    Hurkmans, C.W.3
  • 17
    • 33947496591 scopus 로고    scopus 로고
    • Is a single respiratory correlated 4D-CT study sufficient for evaluation of breathing motion?
    • Guckenberger M., Wilbert J., Meyer J., et al. Is a single respiratory correlated 4D-CT study sufficient for evaluation of breathing motion?. Int J Radiat Oncol Biol Phys 67 (2007) 1352-1359
    • (2007) Int J Radiat Oncol Biol Phys , vol.67 , pp. 1352-1359
    • Guckenberger, M.1    Wilbert, J.2    Meyer, J.3
  • 18
    • 33845951339 scopus 로고    scopus 로고
    • How extensive of a 4D dataset is needed to estimate cumulative dose distribution plan evaluation metrics in conformal lung therapy?
    • Rosu M., Balter J.M., Chetty I.J., et al. How extensive of a 4D dataset is needed to estimate cumulative dose distribution plan evaluation metrics in conformal lung therapy?. Med Phys 34 (2007) 233-245
    • (2007) Med Phys , vol.34 , pp. 233-245
    • Rosu, M.1    Balter, J.M.2    Chetty, I.J.3
  • 19
    • 39749145316 scopus 로고    scopus 로고
    • Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients
    • Wolthaus J.W.H., Sonke J.J., van Herk M., et al. Comparison of different strategies to use four-dimensional computed tomography in treatment planning for lung cancer patients. Int J Radiat Oncol Biol Phys 70 (2008) 1229-1238
    • (2008) Int J Radiat Oncol Biol Phys , vol.70 , pp. 1229-1238
    • Wolthaus, J.W.H.1    Sonke, J.J.2    van Herk, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.