메뉴 건너뛰기




Volumn 42, Issue 10, 2009, Pages 1574-1577

Resolving the time lag between pressure and flow for the determination of local wave speed in elastic tubes and arteries

Author keywords

Hemodynamics; Pressure; PU loop; Pulse wave velocity; Time lag; Velocity; Wave speed

Indexed keywords

CORRELATION FACTORS; ELASTIC TUBES; FLOW WAVEFORMS; IN-VITRO; IN-VIVO; LATEX TUBES; LOCAL WAVE; MAXIMUM VELOCITY; MEASURING DEVICE; MINIMUM PRESSURE; PRESSURE WAVEFORMS; PRESSURE-VELOCITY; PU-LOOP; PULSE WAVE VELOCITY; SAMPLING INTERVAL; TIME LAG; TIME SHIFTS; TIME STEP; WAVE SPEED;

EID: 67649484378     PISSN: 00219290     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jbiomech.2009.03.038     Document Type: Article
Times cited : (17)

References (12)
  • 1
    • 0032898657 scopus 로고    scopus 로고
    • London GM, Safar ME. Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
    • Blacher J., Asmar R., and Djane S. London GM, Safar ME. Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients. Hypertension 33 (1999) 1111-1117
    • (1999) Hypertension , vol.33 , pp. 1111-1117
    • Blacher, J.1    Asmar, R.2    Djane, S.3
  • 2
    • 34250873889 scopus 로고    scopus 로고
    • Wave dissipation in flexible tubes in the time domain: an arterial model
    • Feng J., Long Q., and Khir A.W. Wave dissipation in flexible tubes in the time domain: an arterial model. J. Biomech. 40 10 (2007) 2130-2138
    • (2007) J. Biomech. , vol.40 , Issue.10 , pp. 2130-2138
    • Feng, J.1    Long, Q.2    Khir, A.W.3
  • 3
    • 0036969855 scopus 로고    scopus 로고
    • On-line noninvasive one-point measurements of pulse wave velocity
    • Harada A., Okada T., Niki K., Chang D., and Sugawara M. On-line noninvasive one-point measurements of pulse wave velocity. Heart Vessels 7 2 (2002) 61-68
    • (2002) Heart Vessels , vol.7 , Issue.2 , pp. 61-68
    • Harada, A.1    Okada, T.2    Niki, K.3    Chang, D.4    Sugawara, M.5
  • 5
    • 0026689951 scopus 로고
    • Effect of reduced aortic compliance on cardiac efficiency and contractile function of in situ canine left ventricle
    • Kelly R.P., Tunin R., and Kass D.A. Effect of reduced aortic compliance on cardiac efficiency and contractile function of in situ canine left ventricle. Cir. Res. 71 (1992) 490-502
    • (1992) Cir. Res. , vol.71 , pp. 490-502
    • Kelly, R.P.1    Tunin, R.2    Kass, D.A.3
  • 6
    • 0034892079 scopus 로고    scopus 로고
    • Determination of wave speed and wave separation in the arteries
    • Khir A.W., O'Brien A., Gibs S., and Parker K.H. Determination of wave speed and wave separation in the arteries. J. Biomech. 34 (2001) 1145-1155
    • (2001) J. Biomech. , vol.34 , pp. 1145-1155
    • Khir, A.W.1    O'Brien, A.2    Gibs, S.3    Parker, K.H.4
  • 7
    • 0344440930 scopus 로고    scopus 로고
    • Local and regional wave speed in the aorta: effects of arterial occlusion
    • Khir A.W., Zambanini A., and Parker K.H. Local and regional wave speed in the aorta: effects of arterial occlusion. Med. Eng. Phys. 26 (2004) 23-29
    • (2004) Med. Eng. Phys. , vol.26 , pp. 23-29
    • Khir, A.W.1    Zambanini, A.2    Parker, K.H.3
  • 8
    • 0035714567 scopus 로고    scopus 로고
    • Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients
    • Laurent S., Boutouyrie P., Asmar R., Gautier I., Laloux B., Guize L., Ducimetiere P., and Benetos A. Aortic stiffness is an independent predictor of all-cause and cardiovascular mortality in hypertensive patients. Hypertension 37 (2001) 1236-1241
    • (2001) Hypertension , vol.37 , pp. 1236-1241
    • Laurent, S.1    Boutouyrie, P.2    Asmar, R.3    Gautier, I.4    Laloux, B.5    Guize, L.6    Ducimetiere, P.7    Benetos, A.8
  • 11
    • 33845714188 scopus 로고    scopus 로고
    • Johannes von Kries and the history of the water hammer
    • Tijsseling A.S., and Anderson A. Johannes von Kries and the history of the water hammer. J. Hydraul. Eng. 133 (2007) 1-8
    • (2007) J. Hydraul. Eng. , vol.133 , pp. 1-8
    • Tijsseling, A.S.1    Anderson, A.2
  • 12
    • 67649551872 scopus 로고    scopus 로고
    • Transonic Systems Inc, Research Flowmeters:, Technical Note 94, accessed in March 2009
    • Transonic Systems Inc., Research Flowmeters: Frequency Response & Delay. Technical Note 94, 〈http://www.transonic.com/TN___94_Frequency_response.pdf〉, accessed in March 2009.
    • Frequency Response & Delay


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.