메뉴 건너뛰기




Volumn 102, Issue 6, 2009, Pages 779-784

Value of a single preoperative PFA-100® measurement in assessing the risk of bleeding in patients taking cyclooxygenase inhibitors and undergoing total knee replacement

Author keywords

Blood, anticoagulants; Blood, platelets; Complications, haemorrhage; Non steroidal anti inflammatory drugs; Surgery, postoperative period

Indexed keywords

ADRENALIN; PROSTAGLANDIN SYNTHASE INHIBITOR; PYROPHOSPHATE;

EID: 67649450291     PISSN: 00070912     EISSN: 14716771     Source Type: Journal    
DOI: 10.1093/bja/aep091     Document Type: Article
Times cited : (14)

References (17)
  • 1
    • 0036344893 scopus 로고    scopus 로고
    • Clinical application of the PFA-100
    • Favaloro EJ. Clinical application of the PFA-100. Curr Opin Hematol 2002; 9: 407-15
    • (2002) Curr Opin Hematol , vol.9 , pp. 407-415
    • Favaloro, E.J.1
  • 2
    • 0034867946 scopus 로고    scopus 로고
    • Platelet function analyzer (PFA-100): A tool to quantify congenital or acquired platelet dysfunction
    • Jilma B. Platelet function analyzer (PFA-100): a tool to quantify congenital or acquired platelet dysfunction. J Lab Clin Med 2001; 138: 152-63
    • (2001) J Lab Clin Med , vol.138 , pp. 152-163
    • Jilma, B.1
  • 4
    • 15944391012 scopus 로고    scopus 로고
    • Brief communication: Duration of platelet dysfunction after a 7-day course of Ibuprofen
    • Goldenberg NA, Jacobson L, Manco-Johnson MJ. Brief communication: duration of platelet dysfunction after a 7-day course of Ibuprofen. Ann Intern Med 2005; 142: 506-9
    • (2005) Ann Intern Med , vol.142 , pp. 506-509
    • Goldenberg, N.A.1    Jacobson, L.2    Manco-Johnson, M.J.3
  • 5
    • 33846407954 scopus 로고    scopus 로고
    • Hemostatic function in healthy pregnant and preeclamptic women: An assessment using the platelet function analyzer (PFA-100) and thromboelastograph
    • Davies JR, Fernando R, Hallworth SP. Hemostatic function in healthy pregnant and preeclamptic women: an assessment using the platelet function analyzer (PFA-100) and thromboelastograph. Anesth Analg 2007; 104: 416-20
    • (2007) Anesth Analg , vol.104 , pp. 416-420
    • Davies, J.R.1    Fernando, R.2    Hallworth, S.P.3
  • 7
    • 37049030370 scopus 로고    scopus 로고
    • The potential use of desmopressin to correct hypothermia-induced impairment of primary haemostasis: An in vitro study using PFA-100
    • Ying CL, Tsang SF, Ng KF. The potential use of desmopressin to correct hypothermia-induced impairment of primary haemostasis: an in vitro study using PFA-100. Resuscitation 2008; 76: 129-33
    • (2008) Resuscitation , vol.76 , pp. 129-133
    • Ying, C.L.1    Tsang, S.F.2    Ng, K.F.3
  • 9
    • 0032773694 scopus 로고    scopus 로고
    • Evaluation of the PFA-100 system in the diagnosis and therapeutic monitoring of patients with von Willebrand disease
    • Cattaneo M, Federici AB, Lecchi A, et al. Evaluation of the PFA-100 system in the diagnosis and therapeutic monitoring of patients with von Willebrand disease. Thromb Haemost 1999; 82: 35-9
    • (1999) Thromb Haemost , vol.82 , pp. 35-39
    • Cattaneo, M.1    Federici, A.B.2    Lecchi, A.3
  • 10
    • 0037220690 scopus 로고    scopus 로고
    • The predictive value of modified computerized thromboelastography and platelet function analysis for postoperative blood loss in routine cardiac surgery
    • Cammerer U, Dietrich W, Rampf T, Braun SL, Richter JA. The predictive value of modified computerized thromboelastography and platelet function analysis for postoperative blood loss in routine cardiac surgery. Anesth Analg 2003; 96: 51-7
    • (2003) Anesth Analg , vol.96 , pp. 51-57
    • Cammerer, U.1    Dietrich, W.2    Rampf, T.3    Braun, S.L.4    Richter, J.A.5
  • 11
    • 0038056053 scopus 로고    scopus 로고
    • Does the platelet function analyser (PFA-100) predict blood loss after cardiopulmonary bypass?
    • Fattorutto M, Pradier O, Schmartz D, Ickx B, Barvais L. Does the platelet function analyser (PFA-100) predict blood loss after cardiopulmonary bypass? Br J Anaesth 2003; 90: 692-3
    • (2003) Br J Anaesth , vol.90 , pp. 692-693
    • Fattorutto, M.1    Pradier, O.2    Schmartz, D.3    Ickx, B.4    Barvais, L.5
  • 12
    • 0035080725 scopus 로고    scopus 로고
    • Reversible shear-mediated platelet dysfunction during cardiac surgery as assessed by the PFA-100 platelet function analyzer
    • Slaughter TF, Sreeram G, Sharma AD, El-Moalem H, East CJ, Greenberg CS. Reversible shear-mediated platelet dysfunction during cardiac surgery as assessed by the PFA-100 platelet function analyzer. Blood Coagul Fibrinolysis 2001; 12: 85-93
    • (2001) Blood Coagul Fibrinolysis , vol.12 , pp. 85-93
    • Slaughter, T.F.1    Sreeram, G.2    Sharma, A.D.3    El-Moalem, H.4    East, C.J.5    Greenberg, C.S.6
  • 13
    • 0031659859 scopus 로고    scopus 로고
    • Wahba A, Sander S, Birnbaum DE. Are in vitro platelet function tests useful in predicting blood loss following open heart surgery? Thorac Cardiovasc Surg 1998; 46: 228-31
    • Wahba A, Sander S, Birnbaum DE. Are in vitro platelet function tests useful in predicting blood loss following open heart surgery? Thorac Cardiovasc Surg 1998; 46: 228-31
  • 14
    • 38349126676 scopus 로고    scopus 로고
    • Response variability to aspirin as assessed by the platelet function analyzer (PFA)-100. A systematic review
    • Crescente M, Di CA, Iacoviello L, Vermylen J, Cerletti C, de Gaetano G. Response variability to aspirin as assessed by the platelet function analyzer (PFA)-100. A systematic review. Thromb Haemost 2008; 99: 14-26
    • (2008) Thromb Haemost , vol.99 , pp. 14-26
    • Crescente, M.1    Di, C.A.2    Iacoviello, L.3    Vermylen, J.4    Cerletti, C.5    de Gaetano, G.6
  • 15
    • 40749108923 scopus 로고    scopus 로고
    • Comprehensive preoperative evaluation of platelet function in total knee arthroplasty patients taking diclofenac
    • Ng KF, Lawmin JC, Li CC, Tsang SF, Tang WM, Chiu KY. Comprehensive preoperative evaluation of platelet function in total knee arthroplasty patients taking diclofenac. J Arthroplasty 2008; 23: 424-30
    • (2008) J Arthroplasty , vol.23 , pp. 424-430
    • Ng, K.F.1    Lawmin, J.C.2    Li, C.C.3    Tsang, S.F.4    Tang, W.M.5    Chiu, K.Y.6
  • 16
    • 0035833502 scopus 로고    scopus 로고
    • The coxibs, selective inhibitors of cyclooxygenase-2
    • FitzGerald GA, Patrono C. The coxibs, selective inhibitors of cyclooxygenase-2. N Engl J Med 2001; 345: 433-42
    • (2001) N Engl J Med , vol.345 , pp. 433-442
    • FitzGerald, G.A.1    Patrono, C.2
  • 17
    • 1842852176 scopus 로고    scopus 로고
    • A practical concept for preoperative management of patients with impaired primary hemostasis
    • Koscielny J, von Tempelhoff GF, Ziemer S, et al. A practical concept for preoperative management of patients with impaired primary hemostasis. Clin Appl Thromb Hemost 2004; 10: 155-66
    • (2004) Clin Appl Thromb Hemost , vol.10 , pp. 155-166
    • Koscielny, J.1    von Tempelhoff, G.F.2    Ziemer, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.