Volumn 9, Issue 10, 2009, Pages 1907-1914

Development of a polypyrrole-based amperometric phosphate biosensor

Author keywords

Bienzyme; Biosensor; Purine nucleotide phosphorylase amperometric measurement; Pyrrole; Xanthine oxidase

Indexed keywords

AMPEROMETRIC MEASUREMENTS; BIENZYME; LINEAR CONCENTRATION; NUCLEOSIDE PHOSPHORYLASE; PHOSPHATE BIOSENSORS; POTASSIUM FERROCYANIDE; PYRROLE; XANTHINE OXIDASE;

EID: 67649432787     PISSN: 18125654     EISSN: 18125662     Source Type: Journal    
DOI: 10.3923/jas.2009.1907.1914     Document Type: Article
Times cited : (9)

References (36)
  • 1
    • 0035341205 scopus 로고    scopus 로고
    • Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose
    • Adeloju, S.B. and A.N. Moline, 2001. Fabrication of ultra-thin polypyrrole-glucose oxidase film from supporting electrolyte-free monomer solution for potentiometric biosensing of glucose. Biosens. Bioelect, 16: 133-139.
    • (2001) Biosens. Bioelect. , vol.16 , pp. 133-139
    • Adeloju, S.B.1    Moline, A.N.2
  • 2
    • 34548127954 scopus 로고    scopus 로고
    • Construction of an amperometric pyruvate oxidase enzyme electrode for determination of pyruvate and phosphate
    • Akylmaz, E. and E. Yorgancia, 2007. Construction of an amperometric pyruvate oxidase enzyme electrode for determination of pyruvate and phosphate. Electrochim. Acta, 52: 7972-7977.
    • (2007) Electrochim. Acta , vol.52 , pp. 7972-7977
    • Akylmaz, E.1    Yorgancia, E.2
  • 4
    • 0040752067 scopus 로고    scopus 로고
    • Determination of phosphate in cola beverages using nonsuppressed ion chromatography: An experiment introducing ion chromatography for quantitative analysis
    • Bello, M. and A. Gonzalez, 1996. Determination of phosphate in cola beverages using nonsuppressed ion chromatography: an experiment introducing ion chromatography for quantitative analysis. J. Chem. Educ.,73: 1174-1174.
    • (1996) J. Chem. Educ. , vol.73 , pp. 1174-1174
    • Bello, M.1    Gonzalez, A.2
  • 6
    • 0027372402 scopus 로고
    • Potentiometric phosphate selective electrode based on a multidentate-tin(IV) carrier
    • Chaniotakis, N.A., K. Jurkschat and A. Ruhlemann, 1993. Potentiometric phosphate selective electrode based on a multidentate-tin(IV) carrier. Anal. Chim. Acta, 282: 345-352.
    • (1993) Anal. Chim. Acta , vol.282 , pp. 345-352
    • Chaniotakis, N.A.1    Jurkschat, K.2    Ruhlemann, A.3
  • 7
    • 0039907244 scopus 로고    scopus 로고
    • Flow injection potentiometric detection of phosphates using a metallic cobalt wire
    • Chen, Z., R. De Marco and P.W. Alexander, 1997. Flow injection potentiometric detection of phosphates using a metallic cobalt wire. Anal. Commun., 34: 93-95.
    • (1997) Anal. Commun. , vol.34 , pp. 93-95
    • Chen, Z.1    de Marco, R.2    Alexander, P.W.3
  • 8
    • 0030593350 scopus 로고    scopus 로고
    • Determination of total phosphorus in sediments by means of high pressure bombs and ion chromatography
    • Colina, M., H. Ledo, E. Gutienez, E. Villalobos and J. Marin, 1996. Determination of total phosphorus in sediments by means of high pressure bombs and ion chromatography. J. Chromatogr. A, 739: 223-227.
    • (1996) J. Chromatogr. A , vol.739 , pp. 223-227
    • Colina, M.1    Ledo, H.2    Gutienez, E.3    Villalobos, E.4    Marin, J.5
  • 9
    • 0029061287 scopus 로고
    • A novel enzyme sensor for the determination of inorganic phosphate
    • Conrath, N., B. Grundig, S. Huwel and K. Cammann, 1995. A novel enzyme sensor for the determination of inorganic phosphate. Anal. Chim. Acta, 309: 47-52.
    • (1995) Anal. Chim. Acta , vol.309 , pp. 47-52
    • Conrath, N.1    Grundig, B.2    Huwel, S.3    Cammann, K.4
  • 10
    • 0025109707 scopus 로고
    • Phosphate-sensitive enzyme electrode: A potential sensor for environmental control
    • D'Urso, E.M. and P. Coulet, 1990. Phosphate-sensitive enzyme electrode: A potential sensor for environmental control. Anal. Chim. Acta, 239: 1-5.
    • (1990) Anal. Chim. Acta , vol.239 , pp. 1-5
    • D'Urso, E.M.1    Coulet, P.2
  • 11
    • 0027272916 scopus 로고
    • Effect of enzyme ratio and enzyme loading on the performance of a bienzymatic electrochemical phosphate biosensor
    • D'Urso, E.M. and P.R Coulet 1993. Effect of enzyme ratio and enzyme loading on the performance of a bienzymatic electrochemical phosphate biosensor. Anal. Chim. Acta, 281: 535-542.
    • (1993) Anal. Chim. Acta , vol.281 , pp. 535-542
    • D'Urso, E.M.1    Coulet, P.R.2
  • 12
    • 0041423781 scopus 로고    scopus 로고
    • Determination of phosphate in hydroponic nutrient solutions using flow injection potentiometry and a cobalt-wire phosphate ion selective electrode
    • De Marco, R. and C. Phan, 2003. Determination of phosphate in hydroponic nutrient solutions using flow injection potentiometry and a cobalt-wire phosphate ion selective electrode. Talanta, 60: 1215-1221.
    • (2003) Talanta , vol.60 , pp. 1215-1221
    • de Marco, R.1    Phan, C.2
  • 13
    • 0032532455 scopus 로고    scopus 로고
    • The phosphate sensor
    • Engblom, S.O., 1998. The phosphate sensor. Biosens. Bioelect, 13: 213-213.
    • (1998) Biosens. Bioelect. , vol.13 , pp. 213-213
    • Engblom, S.O.1
  • 14
    • 0016837550 scopus 로고
    • A phosphate-selective electrode based on immobilised alkaline phosphatase and glucose oxidase
    • Guilbault G. and M. Nanjo, 1975. A phosphate-selective electrode based on immobilised alkaline phosphatase and glucose oxidase. Anal. Chim. Acta, 78: 69-74.
    • (1975) Anal. Chim. Acta , vol.78 , pp. 69-74
    • Guilbault, G.1    Nanjo, M.2
  • 16
    • 0025221701 scopus 로고
    • Amperometric determination of phosphate by use of a nucleoside phosphorylase-xanthine oxidase enzyme sensor based on a clark-type hydrogen peroxide or oxygen electrode
    • Haemmerh, S.D., A.A. Suleiman, G.G. Guilbault 1990. Amperometric determination of phosphate by use of a nucleoside phosphorylase-xanthine oxidase enzyme sensor based on a clark-type hydrogen peroxide or oxygen electrode. Anal. Biochem., 191: 106-109.
    • (1990) Anal. Biochem. , vol.191 , pp. 106-109
    • Haemmerh, S.D.1    Suleiman, A.A.2    Guilbault, G.G.3
  • 18
    • 49949123410 scopus 로고
    • Phosphorus in flowing waters
    • Keup, L.L., 1968. Phosphorus in flowing waters. Water Res., 2: 373-373.
    • (1968) Water Res. , vol.2 , pp. 373-373
    • Keup, L.L.1
  • 19
    • 0028939663 scopus 로고
    • An amperometric-enzymatic method for assays of inorganic phosphate and adenosine deaminase in serum based on the measurement of uric acid with a dialysis membrane-covered carbon electrode
    • Komsita, PL, D. Yoshidaa, K. Miki, T. Usui and T. Ikeda, 1995. An amperometric-enzymatic method for assays of inorganic phosphate and adenosine deaminase in serum based on the measurement of uric acid with a dialysis membrane-covered carbon electrode. Anal. Chim. Acta, 303: 301-307.
    • (1995) Anal. Chim. Acta , vol.303 , pp. 301-307
    • Komsita, P.L.1    Yoshidaa, D.2    Miki, K.3    Usui, T.4    Ikeda, T.5
  • 20
    • 0026589713 scopus 로고
    • Amperometric determination of phosphate ions by biosensor
    • Kulys, J., I. Higgins and J. Bannister, 1992. Amperometric determination of phosphate ions by biosensor. Biosens. Bioelect, 7: 187-191.
    • (1992) Biosens. Bioelect , vol.7 , pp. 187-191
    • Kulys, J.1    Higgins, I.2    Bannister, J.3
  • 21
    • 67649227184 scopus 로고    scopus 로고
    • Fabrication of potentiometric hypoxanthine sensor for determination of fish freshness
    • Lawal, A.T. and S.B. Adeloju, 2008. Fabrication of potentiometric hypoxanthine sensor for determination of fish freshness. J. Applied Sci., 8: 2599-2605.
    • (2008) J. Applied Sci. , vol.8 , pp. 2599-2605
    • Lawal, A.T.1    Adeloju, S.B.2
  • 22
    • 33846338801 scopus 로고    scopus 로고
    • PVC matrix membrane sensor for fluorescent determination of phosphate
    • Lin, X., X. Wu, Z. Xie and K.Y. Wong, 2006. PVC matrix membrane sensor for fluorescent determination of phosphate. Talanta, 70: 32-36.
    • (2006) Talanta , vol.70 , pp. 32-36
    • Lin, X.1    Wu, X.2    Xie, Z.3    Wong, K.Y.4
  • 23
    • 0025784569 scopus 로고
    • An FIA biosensor system for the determination of phosphate
    • Male, K. and J. Luong, 1991. An FIA biosensor system for the determination of phosphate. Biosens. Bioelect, 6: 581-587.
    • (1991) Biosens. Bioelect , vol.6 , pp. 581-587
    • Male, K.1    Luong, J.2
  • 25
    • 17844390691 scopus 로고    scopus 로고
    • Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques
    • Motomisu, S. and Z.H. Li, 2005. Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques. Talanta, 66: 332-340.
    • (2005) Talanta , vol.66 , pp. 332-340
    • Motomisu, S.1    Li, Z.H.2
  • 26
    • 0035850586 scopus 로고    scopus 로고
    • Trienzymatic biosensor for the determination of inorganic phosphate
    • Mousty, C, S. Cosmer, D. Shan and S. Mu, 2001. Trienzymatic biosensor for the determination of inorganic phosphate. Anal. Chim. Acta, 443: 1-8.
    • (2001) Anal. Chim. Acta , vol.443 , pp. 1-8
    • Mousty, C.1    Cosmer, S.2    Shan, D.3    Mu, S.4
  • 27
    • 0030745604 scopus 로고    scopus 로고
    • Calcium and osteoporosis
    • Nordin, B.E.C., 1997. Calcium and osteoporosis. Nutrition, 13: 664-672.
    • (1997) Nutrition , vol.13 , pp. 664-672
    • Nordin, B.E.C.1
  • 28
    • 33845437905 scopus 로고    scopus 로고
    • A biosensor for inorganicphosphate using Rodamine labneled phosphate bidng protein
    • Okoh, M.P., J.L. Hunter, J.E.T. Come and M.R. Webb, 2006. A biosensor for inorganicphosphate using Rodamine labneled phosphate bidng protein. Biochemistry, 45: 14764-14771.
    • (2006) Biochemistry , vol.45 , pp. 14764-14771
    • Okoh, M.P.1    Hunter, J.L.2    Come, J.E.T.3    Webb, M.R.4
  • 29
    • 29144516685 scopus 로고    scopus 로고
    • The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations
    • Rahman, M.A., D.S. Park, S.C. Chang and C.J. Mcneil, 2006. The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations. Biosens. Bioelect, 21: 1116-1124.
    • (2006) Biosens. Bioelect , vol.21 , pp. 1116-1124
    • Rahman, M.A.1    Park, D.S.2    Chang, S.C.3    McNeil, C.J.4
  • 30
    • 0028873741 scopus 로고
    • AP-GOD biosensor based on a modified poly(phenol) film electrode and its application in the determination of low levels of phosphate
    • Su, Y. and M. Mascini, 1995. AP-GOD biosensor based on a modified poly(phenol) film electrode and its application in the determination of low levels of phosphate. Anal. Lett, 28: 1359-1378.
    • (1995) Anal. Lett. , vol.28 , pp. 1359-1378
    • Su, Y.1    Mascini, M.2
  • 31
    • 0023521664 scopus 로고
    • Determination of phosphate Ions with an enzyme sensor system
    • Watanabe, E., H. Endo and K. Toyama, 1987. Determination of phosphate Ions with an enzyme sensor system. Biosensors, 3: 297-306.
    • (1987) Biosensors , vol.3 , pp. 297-306
    • Watanabe, E.1    Endo, H.2    Toyama, K.3
  • 32
    • 0026836074 scopus 로고
    • Biosensor for sensitive phosphate detection
    • Wollemberger, U. and F. Schuber, 1992. Biosensor for sensitive phosphate detection. Sens. Actuators, 7: 412-415.
    • (1992) Sens. Actuators , vol.7 , pp. 412-415
    • Wollemberger, U.1    Schuber, F.2
  • 33
    • 0023892922 scopus 로고
    • Flow-injection system for simultaneous assay of free and total cholesterol in blood serum by use of immobilized enzymes
    • Yao, T. and T. Wasa, 1988. Flow-injection system for simultaneous assay of free and total cholesterol in blood serum by use of immobilized enzymes. Anal. Chim. Acta, 207: 319-323.
    • (1988) Anal. Chim. Acta , vol.207 , pp. 319-323
    • Yao, T.1    Wasa, T.2
  • 34
    • 0038449894 scopus 로고    scopus 로고
    • Simultaneous determination of orthophosphate and total phosphates (inorganic phosphates plus purine nucleotides) using a bioamperometric flow-injection system made up by a 16-way switching valve
    • Yao, T., K. Takashima and N. Youko, 2003. Simultaneous determination of orthophosphate and total phosphates (inorganic phosphates plus purine nucleotides) using a bioamperometric flow-injection system made up by a 16-way switching valve. Talanta, 60: 845-851.
    • (2003) Talanta , vol.60 , pp. 845-851
    • Yao, T.1    Takashima, K.2    Youko, N.3
  • 35
    • 1942472023 scopus 로고    scopus 로고
    • Determination of nanomolar concentrations of phosphate in freshwaters using flow injection with luminol chemiluminescence detection
    • Yaqoob, M., A. Nabi and P.J. Worsold, 2004. Determination of nanomolar concentrations of phosphate in freshwaters using flow injection with luminol chemiluminescence detection. Anal. Chim. Acta, 510: 213-218.
    • (2004) Anal. Chim. Acta , vol.510 , pp. 213-218
    • Yaqoob, M.1    Nabi, A.2    Worsold, P.J.3
  • 36
    • 43049094018 scopus 로고    scopus 로고
    • Development of a conductometric phosphate biosensor based on tri-layer maltose phosphorylase composite films
    • Zhanga, Z., J.R. Nicole, F. Bessueillea, D. Leonarda and S. Xia, et al., 2008. Development of a conductometric phosphate biosensor based on tri-layer maltose phosphorylase composite films. Anal. Chim. Acta, 615: 73-79.
    • (2008) Anal. Chim. Acta , vol.615 , pp. 73-79
    • Zhanga, Z.1    Nicole, J.R.2    Bessueillea, F.3    Leonarda, D.4    Xia, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.