메뉴 건너뛰기




Volumn 93, Issue 9, 2009, Pages 1492-1498

Comparison of vacuum glazing thermal performance predicted using two- and three-dimensional models and their experimental validation

Author keywords

Finite element model; Finite volume model; Thermal performance; Vacuum glazing

Indexed keywords

2-D MODEL; 3D MODELS; EFFECTIVE THERMAL CONDUCTIVITY; EXPERIMENTAL VALIDATIONS; FINITE ELEMENT; FINITE ELEMENT MODEL; FINITE VOLUME MODEL; GLASS SURFACES; OVERALL HEAT TRANSFER COEFFICIENT; PILLAR ARRAYS; RADIATION HEAT TRANSFER; SPACE WIDTH; TEMPERATURE PROFILES; THERMAL PERFORMANCE; THREE-DIMENSIONAL MODEL; VACUUM GAP; VACUUM GLAZING; VACUUM WINDOWS;

EID: 67649410167     PISSN: 09270248     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solmat.2009.03.025     Document Type: Article
Times cited : (51)

References (23)
  • 1
    • 67649406935 scopus 로고
    • German Patent Application No. 387655
    • A. Zoller, Hohle Glasscheibe, German Patent Application No. 387655, 1913.
    • (1913)
    • Zoller, A.1    Glasscheibe, H.2
  • 2
    • 35948951009 scopus 로고    scopus 로고
    • Method and equipment for making heat-insulating construction and/or lighting element,
    • European Patent No. 1221526
    • K. Sager-Hintermann, E. Baechli, Method and equipment for making heat-insulating construction and/or lighting element, European Patent No. 1221526, 2002.
    • (2002)
    • Sager-Hintermann, K.1    Baechli, E.2
  • 3
    • 85054811931 scopus 로고    scopus 로고
    • Fraunhofer Institute for Solar Energy Systems, Freiburg, Germany
    • Wittwer V. Private Communicate (2005), Fraunhofer Institute for Solar Energy Systems, Freiburg, Germany
    • (2005) Private Communicate
    • Wittwer, V.1
  • 7
    • 67649398402 scopus 로고    scopus 로고
    • Method of sealing glass,
    • United States Patent US 7, 204, 102 B1, 17 April 2007
    • P.C. Eames, B. Norton, P.W. Griffith, T.J. Hyde, Method of sealing glass, United States Patent US 7, 204, 102 B1, 17 April 2007.
    • Eames, P.C.1    Norton, B.2    Griffith, P.W.3    Hyde, T.J.4
  • 8
    • 33751255953 scopus 로고    scopus 로고
    • Triple vacuum glazing: heat transfer and basic mechanical design constraints
    • Manz H., Brunner S., and Wullschleger L. Triple vacuum glazing: heat transfer and basic mechanical design constraints. Solar Energy 80 (2006) 1632-1642
    • (2006) Solar Energy , vol.80 , pp. 1632-1642
    • Manz, H.1    Brunner, S.2    Wullschleger, L.3
  • 9
    • 0027189372 scopus 로고
    • Heat transfer at the edge of sealed insulating glass unit: comparison of hot box measurements with finite-difference model
    • Elmahdy A.H., and Frank T.h. Heat transfer at the edge of sealed insulating glass unit: comparison of hot box measurements with finite-difference model. ASHRAE Transactions: Symposia (1993) 915-922
    • (1993) ASHRAE Transactions: Symposia , pp. 915-922
    • Elmahdy, A.H.1    Frank, T.h.2
  • 10
    • 0029213709 scopus 로고
    • A two-dimensional numerical model for glazing system thermal analysis
    • Wright J.L., and Sullivan H.F. A two-dimensional numerical model for glazing system thermal analysis. ASHRAE Transactions: Symposia (1995) 819-831
    • (1995) ASHRAE Transactions: Symposia , pp. 819-831
    • Wright, J.L.1    Sullivan, H.F.2
  • 11
    • 0028720757 scopus 로고
    • Two-dimensional finite-element model of heat transfer in complete fenestration systems
    • Curcija D D., and Goss W.P. Two-dimensional finite-element model of heat transfer in complete fenestration systems. ASHRAE Transactions: Symposia (1994) 1207-1220
    • (1994) ASHRAE Transactions: Symposia , pp. 1207-1220
    • Curcija D, D.1    Goss, W.P.2
  • 12
    • 0032030224 scopus 로고    scopus 로고
    • Current status of the sciences and technology of vacuum glazing
    • Collins R.E., and Simko T.M. Current status of the sciences and technology of vacuum glazing. Solar Energy 62 (1998) 189-213
    • (1998) Solar Energy , vol.62 , pp. 189-213
    • Collins, R.E.1    Simko, T.M.2
  • 13
    • 33745684772 scopus 로고    scopus 로고
    • The effect of glass coating emittance and frame rebate on the heat transfer through vacuum and electrochromic vacuum glazed windows
    • Fang Y., and Eames P.C. The effect of glass coating emittance and frame rebate on the heat transfer through vacuum and electrochromic vacuum glazed windows. Solar Energy Material and Solar Cells 90 (2006) 2683-2695
    • (2006) Solar Energy Material and Solar Cells , vol.90 , pp. 2683-2695
    • Fang, Y.1    Eames, P.C.2
  • 14
    • 33646483347 scopus 로고    scopus 로고
    • Experimental validation of a numerical model for heat transfer in evacuated glazing
    • Fang Y., Eames P.C., Norton B., and Hyde T.J. Experimental validation of a numerical model for heat transfer in evacuated glazing. Solar Energy 80 (2006) 564-577
    • (2006) Solar Energy , vol.80 , pp. 564-577
    • Fang, Y.1    Eames, P.C.2    Norton, B.3    Hyde, T.J.4
  • 15
    • 0027574837 scopus 로고
    • A validated unified model for optics and heat transfer in line-axis concentrating solar energy collectors
    • Eames P.C., and Norton B. A validated unified model for optics and heat transfer in line-axis concentrating solar energy collectors. Solar Energy 50 (1993) 339-355
    • (1993) Solar Energy , vol.50 , pp. 339-355
    • Eames, P.C.1    Norton, B.2
  • 16
    • 0031026592 scopus 로고    scopus 로고
    • The measurement and calculation of radiative heat transfer between uncoated and doped tin oxide coated glass surfaces. The measurement and calculation of radiative heat transfer between uncoated and doped tin oxide coated glass surfaces
    • Zhang Q.-C., Simko T.M., Dey C.J., Collins R.E., Turner G.M., Brunotte M., and Gombert A. The measurement and calculation of radiative heat transfer between uncoated and doped tin oxide coated glass surfaces. The measurement and calculation of radiative heat transfer between uncoated and doped tin oxide coated glass surfaces. International Journal of Heat and Mass Transfer 40 (1997) 61-71
    • (1997) International Journal of Heat and Mass Transfer , vol.40 , pp. 61-71
    • Zhang, Q.-C.1    Simko, T.M.2    Dey, C.J.3    Collins, R.E.4    Turner, G.M.5    Brunotte, M.6    Gombert, A.7
  • 18
    • 67649395181 scopus 로고    scopus 로고
    • ASTM, Standard procedures for determining the steady state thermal transmittance of fenestration systems, ASTM Standard E 1423-91, in: 1994 Annual Book of ASTM Standard 04.07, American Society of Testing and Materials, 1991, pp. 1160-1165.
    • ASTM, Standard procedures for determining the steady state thermal transmittance of fenestration systems, ASTM Standard E 1423-91, in: 1994 Annual Book of ASTM Standard 04.07, American Society of Testing and Materials, 1991, pp. 1160-1165.
  • 20
    • 0032450098 scopus 로고    scopus 로고
    • Heat conduction through the support pillars in vacuum glazing
    • Wilson C.F., Simko T.M., and Collins R.E. Heat conduction through the support pillars in vacuum glazing. Solar Energy 63 6 (1998) 393-406
    • (1998) Solar Energy , vol.63 , Issue.6 , pp. 393-406
    • Wilson, C.F.1    Simko, T.M.2    Collins, R.E.3
  • 21
    • 23844525393 scopus 로고    scopus 로고
    • Complex multimaterial insulating frames for windows with evacuated glazing
    • Fang Y., Eames P.C., Hyde T.J., and Norton B. Complex multimaterial insulating frames for windows with evacuated glazing. Solar Energy 79 (2005) 245-261
    • (2005) Solar Energy , vol.79 , pp. 245-261
    • Fang, Y.1    Eames, P.C.2    Hyde, T.J.3    Norton, B.4
  • 22
    • 33846813524 scopus 로고    scopus 로고
    • The effect of glass thickness on the thermal performance of evacuated glazing
    • Fang Y., Eames P.C., and Norton B. The effect of glass thickness on the thermal performance of evacuated glazing. Solar Energy 81 (2007) 395-404
    • (2007) Solar Energy , vol.81 , pp. 395-404
    • Fang, Y.1    Eames, P.C.2    Norton, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.