메뉴 건너뛰기




Volumn 25, Issue 6, 2009, Pages 503-515

Combined corneal topography and corneal wavefront data in the treatment of corneal irregularity and refractive error in LASIK or PRK using the Carl Zeiss Meditec MEL 80 and CRS-master

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; ASTIGMATISM; CATARACT EXTRACTION; CLINICAL ARTICLE; CONTROLLED STUDY; CORNEA DISEASE; FEMALE; HUMAN; KERATOMETRY; KERATOMILEUSIS; KERATOPLASTY; MALE; MYOPIA; PHOTOREFRACTIVE KERATECTOMY; POSTOPERATIVE PERIOD; PRIORITY JOURNAL; RADIAL KERATOTOMY; REFRACTION ERROR; TREATMENT OUTCOME;

EID: 67649379621     PISSN: 1081597X     EISSN: None     Source Type: Journal    
DOI: 10.3928/1081597X-20090512-04     Document Type: Article
Times cited : (28)

References (22)
  • 2
    • 0033777802 scopus 로고    scopus 로고
    • Topographically-guided laser in situ keratomileusis to treat corneal irregularities
    • DOI 10.1016/S0161-6420(00)00094-4, PII S0161642000000944
    • Knorz MC, Jendritza B. Topographically-guided laser in situ keratomileusis to treat corneal irregularities. Ophthalmology. 2000;107:1138-1143. (Pubitemid 30825515)
    • (2000) Ophthalmology , vol.107 , Issue.6 , pp. 1138-1143
    • Knorz, M.C.1    Jendritza, B.2
  • 3
    • 0033773674 scopus 로고    scopus 로고
    • Topography-driven photorefractive keratectomy: Results of Corneal Interactive Programmed Topographic Ablation software
    • DOI 10.1016/S0161-6420(00)00224-4, PII S0161642000002244
    • Alessio G, Boscia F, La Tegola MG, Sborgia C. Topography-driven photorefractive keratectomy: results of corneal interactive programmed topographic ablation software. Ophthalmology. 2000;107:1578-1587. (Pubitemid 30825872)
    • (2000) Ophthalmology , vol.107 , Issue.8 , pp. 1578-1587
    • Alessio, G.1    Boscia, F.2    La Tegola, M.G.3    Sborgia, C.4
  • 4
    • 0034869410 scopus 로고    scopus 로고
    • Topography-driven excimer laser for the retreatment of decentralized myopic photorefractive keratectomy
    • DOI 10.1016/S0161-6420(01)00706-0, PII S0161642001007060
    • Alessio G, Boscia F, La Tegola MG, Sborgia C. Topography-driven excimer laser for the retreatment of decentralized myopic photorefractive keratectomy. Ophthalmology. 2001;108:1695-1703. (Pubitemid 32808352)
    • (2001) Ophthalmology , vol.108 , Issue.9 , pp. 1695-1703
    • Alessio, G.1    Boscia, F.2    La Tegola, M.G.3    Sborgia, C.4
  • 5
    • 0034760384 scopus 로고    scopus 로고
    • Corneal interactive programmed topographic ablation customized photorefractive keratectomy for correction of postkeratoplasty astigmatism
    • DOI 10.1016/S0161-6420(01)00807-7, PII S0161642001008077
    • Alessio G, Boscia F, La Tegola MG, Sborgia C. Corneal interactive programmed topographic ablation customized photorefractive keratectomy for correction of postkeratoplasty astigmatism. Ophthalmology. 2001;108:2029-2037. (Pubitemid 33032774)
    • (2001) Ophthalmology , vol.108 , Issue.11 , pp. 2029-2037
    • Vajpayee, R.B.1    Dada, T.2    Ray, M.3    Tandon, R.4    Sethi, A.5    Turaka, K.6
  • 6
  • 7
    • 25144484749 scopus 로고    scopus 로고
    • Topography-guided custom retreatments in 27 symptomatic eyes
    • Kanellopoulos AJ. Topography-guided custom retreatments in 27 symptomatic eyes. J Refract Surg. 2005;21:S513-S518. (Pubitemid 41356300)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.5
    • Kanellopoulos, A.J.1
  • 9
    • 0141545224 scopus 로고    scopus 로고
    • Topography-guided laser in situ keratomileusis (TOPOLINK) to correct irregular astigmatism after previous refractive surgery
    • Alió JL, Belda JI, Osman AA, Shalaby AM. Topography-guided laser in situ keratomileusis (TOPOLINK) to correct irregular astigmatism after previous refractive surgery. J Refract Surg. 2003;19:516-527. (Pubitemid 37185898)
    • (2003) Journal of Refractive Surgery , vol.19 , Issue.5 , pp. 516-527
    • Alio, J.L.1    Belda, J.I.2    Osman, A.A.3    Shalaby, A.M.M.4
  • 11
    • 0011060250 scopus 로고
    • Basic wavefront aberration theory for optical metrology
    • Burlington, Mass: Academic Press
    • Wyant JC, Creath K. Basic wavefront aberration theory for optical metrology. In: Applied Optics and Optical Engineering. Vol XI. Burlington, Mass: Academic Press; 1992:2-53.
    • (1992) Applied Optics and Optical Engineering , vol.11 , pp. 2-53
    • Wyant, J.C.1    Creath, K.2
  • 13
    • 3042586618 scopus 로고    scopus 로고
    • Accuracy and precision of objective refraction from wavefront aberrations
    • DOI 10.1167/4.4.9
    • Thibos LN, Hong X, Bradley A, Applegate RA. Accuracy and precision of objective refraction from wavefront aberrations. J Vis. 2004;4:329-351. (Pubitemid 39047437)
    • (2004) Journal of Vision , vol.4 , Issue.4 , pp. 329-351
    • Thibos, L.N.1    Xin, H.2    Bradley, A.3    Applegate, R.A.4
  • 14
    • 0037243289 scopus 로고    scopus 로고
    • Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer
    • DOI 10.1097/00006324-200301000-00003
    • Salmon TO, West RW, Gasser W, Kenmore T. Measurement of refractive errors in young myopes using the COAS Shack-Hartmann aberrometer. Optom Vis Sci. 2003;80:6-14. (Pubitemid 36106062)
    • (2003) Optometry and Vision Science , vol.80 , Issue.1 , pp. 6-14
    • Salmon, T.O.1    West, R.W.2    Gasser, W.3    Kenmore, T.4
  • 15
    • 33645129145 scopus 로고    scopus 로고
    • Accuracy of the WASCA aberrometer refraction compared to manifest refraction in myopia
    • Reinstein DZ, Archer TJ, Couch D. Accuracy of the WASCA aberrometer refraction compared to manifest refraction in myopia. J Refract Surg. 2006;22:268-274.
    • (2006) J Refract Surg , vol.22 , pp. 268-274
    • Reinstein, D.Z.1    Archer, T.J.2    Couch, D.3
  • 16
    • 0032168704 scopus 로고    scopus 로고
    • Comparison of repeat videokeratography: Repeatability and accuracy
    • DOI 10.1097/00006324-199809000-00021
    • Jeandervin M, Barr J. Comparison of repeat videokeratography: repeatability and accuracy. Optom Vis Sci. 1998;75:663-669. (Pubitemid 28459979)
    • (1998) Optometry and Vision Science , vol.75 , Issue.9 , pp. 663-669
    • Jeandervin, M.1    Barr, J.2
  • 17
    • 0029947418 scopus 로고    scopus 로고
    • Evaluating data acquisition and smoothing functions of currently available videokeratoscopes
    • Belin MW, Ratliff CD. Evaluating data acquisition and smoothing functions of currently available videokeratoscopes. J Cataract Refract Surg. 1996;22:421-426. (Pubitemid 26152528)
    • (1996) Journal of Cataract and Refractive Surgery , vol.22 , Issue.4 , pp. 421-426
    • Belin, M.W.1    Ratliff, C.D.2
  • 19
    • 0033900074 scopus 로고    scopus 로고
    • Standard graphs for reporting refractive surgery
    • Waring GO III. Standard graphs for reporting refractive surgery. J Refract Surg. 2000;16:459-466. (Pubitemid 30637482)
    • (2000) Journal of Refractive Surgery , vol.16 , Issue.4 , pp. 459-466
    • Waring III, G.O.1
  • 21
    • 67649358697 scopus 로고    scopus 로고
    • LASIK for hyperopic astigmatism and presbyopia using micromonovision with the Carl Zeiss Meditec MEL80
    • Available at: Posted online May 30, 2008
    • Reinstein DZ, Couch D, Archer TJ. LASIK for hyperopic astigmatism and presbyopia using micromonovision with the Carl Zeiss Meditec MEL80. J Refract Surg. Available at: http://www. journalofrefractivesurgery.com/preprint.asp. Posted online May 30, 2008.
    • J Refract Surg
    • Reinstein, D.Z.1    Couch, D.2    Archer, T.J.3
  • 22
    • 25144472031 scopus 로고    scopus 로고
    • A new night vision disturbances parameter and contrast sensitivity as indicators of success in wavefront-guided enhancement
    • Reinstein DZ, Archer TJ, Couch D, Schroeder E, Wottke M. A new night vision disturbances parameter and contrast sensitivity as indicators of success in wavefront-guided enhancement. J Refract Surg. 2005;21:S535-S540. (Pubitemid 41356304)
    • (2005) Journal of Refractive Surgery , vol.21 , Issue.5
    • Reinstein, D.Z.1    Archer, T.J.2    Couch, D.3    Schroeder, E.4    Wottke, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.