Volumn 30, Issue 2, 2009, Pages 138-143

Evaluation of clinical spasticity assessment in Cerebral palsy using inertial sensors

Author keywords

Biomedical engineering; Cerebral palsy; Movement analysis; Muscle spasticity; Rehabilitation

Indexed keywords

ACCURACY; ADOLESCENT; ARTICLE; CEREBRAL PALSY; CHILD; CLINICAL ARTICLE; CLINICAL ASSESSMENT; CONTROLLED STUDY; GASTROCNEMIUS MUSCLE; GONIOMETRY; HAMSTRING; HUMAN; MUSCLE STRETCHING; PRIORITY JOURNAL; SENSOR; SOLEUS MUSCLE; SPASTICITY; VALIDATION PROCESS;

EID: 67649372478     PISSN: 09666362     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.gaitpost.2009.05.011     Document Type: Article
Times cited : (70)

References (28)
  • 1
    • 33847358156 scopus 로고    scopus 로고
    • Definition and classification of cerebral palsy. From syndrome toward disease
    • Bax M.C., Flodmark O., and Tydeman C. Definition and classification of cerebral palsy. From syndrome toward disease. Dev Med Child Neurol Suppl 109 (2007) 39-41
    • (2007) Dev Med Child Neurol Suppl , vol.109 , pp. 39-41
    • Bax, M.C.1    Flodmark, O.2    Tydeman, C.3
  • 3
    • 0023130157 scopus 로고
    • Interrater reliability of a modified Ashworth scale of muscle spasticity
    • Bohannon R.W., and Smith M.B. Interrater reliability of a modified Ashworth scale of muscle spasticity. Phys Ther 67 2 (1987) 206-207
    • (1987) Phys Ther , vol.67 , Issue.2 , pp. 206-207
    • Bohannon, R.W.1    Smith, M.B.2
  • 4
    • 0033382079 scopus 로고    scopus 로고
    • Objective measurement of clinical findings in the use of botulinum toxin type A for the management of children with cerebral palsy
    • Boyd R.N., and Graham H.K. Objective measurement of clinical findings in the use of botulinum toxin type A for the management of children with cerebral palsy. Eur J Neurol 6 (1999) S23-S35
    • (1999) Eur J Neurol , vol.6
    • Boyd, R.N.1    Graham, H.K.2
  • 5
    • 0034098170 scopus 로고    scopus 로고
    • Sensitivity of the pendulum test for assessing spasticity in persons with cerebral palsy
    • Fowler E.G., Nwigwe A.I., and Ho T.W. Sensitivity of the pendulum test for assessing spasticity in persons with cerebral palsy. Dev Med Child Neurol 42 3 (2000) 182-189
    • (2000) Dev Med Child Neurol , vol.42 , Issue.3 , pp. 182-189
    • Fowler, E.G.1    Nwigwe, A.I.2    Ho, T.W.3
  • 6
    • 67649312462 scopus 로고    scopus 로고
    • Scholtes VAB, Dallmeijer AJ, Becher JG. The Spasticity Test: a clinical instrument to measure spasticity in children with cerebral palsy. In: The effectiveness of multilevel botulinum toxin type A and comprehensive rehabilitation in children with cerebral palsy. Amsterdam, The Netherlands: Ponsen & Looijen BV; 2007. p. 29-64.
    • Scholtes VAB, Dallmeijer AJ, Becher JG. The Spasticity Test: a clinical instrument to measure spasticity in children with cerebral palsy. In: The effectiveness of multilevel botulinum toxin type A and comprehensive rehabilitation in children with cerebral palsy. Amsterdam, The Netherlands: Ponsen & Looijen BV; 2007. p. 29-64.
  • 7
    • 0002407767 scopus 로고    scopus 로고
    • Clinicophysiologic concepts of spasticity and motor dysfunction in adults with an upper motoneuron lesion
    • Mayer N.H. Clinicophysiologic concepts of spasticity and motor dysfunction in adults with an upper motoneuron lesion. Muscle Nerve (1997) S1-S13
    • (1997) Muscle Nerve
    • Mayer, N.H.1
  • 8
    • 31144463601 scopus 로고    scopus 로고
    • Clinical assessment of spasticity in children with cerebral palsy: a critical review of available instruments
    • Scholtes V.A., Becher J.G., Beelen A., and Lankhorst G.J. Clinical assessment of spasticity in children with cerebral palsy: a critical review of available instruments. Dev Med Child Neurol 48 1 (2006) 64-73
    • (2006) Dev Med Child Neurol , vol.48 , Issue.1 , pp. 64-73
    • Scholtes, V.A.1    Becher, J.G.2    Beelen, A.3    Lankhorst, G.J.4
  • 9
    • 4544345754 scopus 로고    scopus 로고
    • Classification and definition of disorders causing hypertonia in childhood
    • Sanger T.D., Delgado M.R., Gaebler-Spira D., Hallett M., and Mink J.W. Classification and definition of disorders causing hypertonia in childhood. Pediatrics 111 1 (2003) 89-97
    • (2003) Pediatrics , vol.111 , Issue.1 , pp. 89-97
    • Sanger, T.D.1    Delgado, M.R.2    Gaebler-Spira, D.3    Hallett, M.4    Mink, J.W.5
  • 10
    • 0034307635 scopus 로고    scopus 로고
    • The variability of goniometric measurements in ambulatory children with spastic cerebral palsy
    • McDowell B.C., Hewitt V., Nurse A., Weston T., and Baker R. The variability of goniometric measurements in ambulatory children with spastic cerebral palsy. Gait Posture 12 2 (2000) 114-121
    • (2000) Gait Posture , vol.12 , Issue.2 , pp. 114-121
    • McDowell, B.C.1    Hewitt, V.2    Nurse, A.3    Weston, T.4    Baker, R.5
  • 12
    • 26444563443 scopus 로고    scopus 로고
    • Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation
    • Roetenberg D., Luinge H.J., Baten C.T., and Veltink P.H. Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation. IEEE Trans Neural Syst Rehabil Eng 13 3 (2005) 395-405
    • (2005) IEEE Trans Neural Syst Rehabil Eng , vol.13 , Issue.3 , pp. 395-405
    • Roetenberg, D.1    Luinge, H.J.2    Baten, C.T.3    Veltink, P.H.4
  • 13
    • 18144397889 scopus 로고    scopus 로고
    • Measuring orientation of human body segments using miniature gyroscopes and accelerometers
    • Luinge H.J., and Veltink P.H. Measuring orientation of human body segments using miniature gyroscopes and accelerometers. Med Biol Eng Comput 43 2 (2005) 273-282
    • (2005) Med Biol Eng Comput , vol.43 , Issue.2 , pp. 273-282
    • Luinge, H.J.1    Veltink, P.H.2
  • 14
    • 0036208446 scopus 로고    scopus 로고
    • Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems
    • Mayagoitia R.E., Nene A.V., and Veltink P.H. Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. J Biomech 35 4 (2002) 537-542
    • (2002) J Biomech , vol.35 , Issue.4 , pp. 537-542
    • Mayagoitia, R.E.1    Nene, A.V.2    Veltink, P.H.3
  • 16
    • 33846933100 scopus 로고    scopus 로고
    • Application of wearable inertial sensors in stroke rehabilitation
    • Zhou H., Hu H., and Harris N. Application of wearable inertial sensors in stroke rehabilitation. Conf Proc IEEE Eng Med Biol Soc 7 (2005) 6825-6828
    • (2005) Conf Proc IEEE Eng Med Biol Soc , vol.7 , pp. 6825-6828
    • Zhou, H.1    Hu, H.2    Harris, N.3
  • 17
    • 33751574271 scopus 로고    scopus 로고
    • Ambulatory measurement of arm orientation
    • Luinge H.J., Veltink P.H., and Baten C.T. Ambulatory measurement of arm orientation. J Biomech 40 1 (2007) 78-85
    • (2007) J Biomech , vol.40 , Issue.1 , pp. 78-85
    • Luinge, H.J.1    Veltink, P.H.2    Baten, C.T.3
  • 18
    • 34250629373 scopus 로고    scopus 로고
    • An inertial and magnetic sensor based technique for joint angle measurement
    • O'Donovan K.J., Kamnik R., O'Keeffe D.T., and Lyons G.M. An inertial and magnetic sensor based technique for joint angle measurement. J Biomech 40 12 (2007) 2604-2611
    • (2007) J Biomech , vol.40 , Issue.12 , pp. 2604-2611
    • O'Donovan, K.J.1    Kamnik, R.2    O'Keeffe, D.T.3    Lyons, G.M.4
  • 19
    • 77955083335 scopus 로고    scopus 로고
    • Estimating body segment orientation by applying inertial and magnetic sensing near ferromagnetic materials
    • Roetenberg D., Baten C.T., and Veltink P.H. Estimating body segment orientation by applying inertial and magnetic sensing near ferromagnetic materials. IEEE Trans Neural Syst Rehabil Eng 15 3 (2007) 469-471
    • (2007) IEEE Trans Neural Syst Rehabil Eng , vol.15 , Issue.3 , pp. 469-471
    • Roetenberg, D.1    Baten, C.T.2    Veltink, P.H.3
  • 20
    • 0030988386 scopus 로고    scopus 로고
    • Development and reliability of a system to classify gross motor function in children with cerebral palsy
    • Palisano R., Rosenbaum P., Walter S., Russell D., Wood E., and Galuppi B. Development and reliability of a system to classify gross motor function in children with cerebral palsy. Dev Med Child Neurol 39 4 (1997) 214-223
    • (1997) Dev Med Child Neurol , vol.39 , Issue.4 , pp. 214-223
    • Palisano, R.1    Rosenbaum, P.2    Walter, S.3    Russell, D.4    Wood, E.5    Galuppi, B.6
  • 21
    • 0032729317 scopus 로고    scopus 로고
    • Coefficient of cross correlation and the time domain correspondence
    • Li L., and Caldwell G.E. Coefficient of cross correlation and the time domain correspondence. J Electromyogr Kinesiol 9 6 (1999) 385-389
    • (1999) J Electromyogr Kinesiol , vol.9 , Issue.6 , pp. 385-389
    • Li, L.1    Caldwell, G.E.2
  • 22
    • 0018841551 scopus 로고
    • Rigid body motion calculated from spatial co-ordinates of markers
    • Spoor C.W., and Veldpaus F.E. Rigid body motion calculated from spatial co-ordinates of markers. J Biomech 13 4 (1980) 391-393
    • (1980) J Biomech , vol.13 , Issue.4 , pp. 391-393
    • Spoor, C.W.1    Veldpaus, F.E.2
  • 23
    • 0021844595 scopus 로고
    • Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics
    • Woltring H.J., Huiskes R., Lange Ad, and Veldpaus F.E. Finite centroid and helical axis estimation from noisy landmark measurements in the study of human joint kinematics. J Biomech 18 5 (1985) 379-389
    • (1985) J Biomech , vol.18 , Issue.5 , pp. 379-389
    • Woltring, H.J.1    Huiskes, R.2    Lange Ad3    Veldpaus, F.E.4
  • 24
    • 60449086044 scopus 로고    scopus 로고
    • The reliability of three-dimensional kinematic gait measurements: a systematic review
    • McGinley J.L., Baker R., Wolfe R., and Morris M.E. The reliability of three-dimensional kinematic gait measurements: a systematic review. Gait Posture 29 3 (2009) 360-369
    • (2009) Gait Posture , vol.29 , Issue.3 , pp. 360-369
    • McGinley, J.L.1    Baker, R.2    Wolfe, R.3    Morris, M.E.4
  • 25
    • 60449098805 scopus 로고    scopus 로고
    • Assessment of the kinematic variability among 12 motion analysis laboratories
    • Gorton III G.E., Hebert D.A., and Gannotti M.E. Assessment of the kinematic variability among 12 motion analysis laboratories. Gait Posture 29 3 (2009) 398-402
    • (2009) Gait Posture , vol.29 , Issue.3 , pp. 398-402
    • Gorton III, G.E.1    Hebert, D.A.2    Gannotti, M.E.3
  • 26
    • 0036077662 scopus 로고    scopus 로고
    • Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation
    • Allington N.J., Leroy N., and Doneux C. Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation. J Pediatr Orthop B 11 3 (2002) 236-239
    • (2002) J Pediatr Orthop B , vol.11 , Issue.3 , pp. 236-239
    • Allington, N.J.1    Leroy, N.2    Doneux, C.3
  • 28
    • 12344255904 scopus 로고    scopus 로고
    • Biomechanical approaches applied to the lower and upper limb for the measurement of spasticity: a systematic review of the literature
    • Wood D.E., Burridge J.H., van Wijck F.M., et al. Biomechanical approaches applied to the lower and upper limb for the measurement of spasticity: a systematic review of the literature. Disabil Rehabil 27 1-2 (2005) 19-32
    • (2005) Disabil Rehabil , vol.27 , Issue.1-2 , pp. 19-32
    • Wood, D.E.1    Burridge, J.H.2    van Wijck, F.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.