메뉴 건너뛰기




Volumn 10, Issue 6, 2009, Pages 395-406

Complications of permanent cardiac pacing and implantable cardioverter-defibrillators;Il rischio iatrogeno connesso all'impianto di pacemaker e defibrillatori

Author keywords

Cardiac resynchronization therapy; Iatrogenic complications; Implantable cardioverter defibrillators; Pacemakers

Indexed keywords

CARDIOLOGIST; CENTRAL VENOUS CATHETER; DEFIBRILLATION; DEFIBRILLATOR; ELECTRIC SHOCK; EMBOLISM; EROSION; EXPERIENCE; HEART ARRHYTHMIA; HEART PACING; HUMAN; IMPLANTATION; INFECTION; PAIN; PERFORATION; PNEUMOTHORAX; POSTOPERATIVE COMPLICATION; PROSTHESIS FAILURE; REVIEW; RISK FACTOR; SKILL; AIR EMBOLISM; ARTIFICIAL HEART PACEMAKER; BLOOD VESSEL; ELECTROCARDIOGRAPHY; ELECTRONICS; EQUIPMENT; EQUIPMENT DESIGN; HEART INJURY; HEART SURGERY; HEART VENTRICLE FIBRILLATION; HEART VENTRICLE TACHYCARDIA; HEMATOMA; HEMATOTHORAX; INJURY; INTRAOPERATIVE PERIOD; POSTOPERATIVE PERIOD; RISK ASSESSMENT; VEIN THROMBOSIS;

EID: 67649233775     PISSN: 18276806     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Review
Times cited : (11)

References (46)
  • 1
    • 36649003893 scopus 로고    scopus 로고
    • Techniques of pacemaker implantation and removal
    • Ellenbogen KA, Wood MA, eds. Oxford, MA: Blackwell Publishing
    • Brinker J, Midei MG. Techniques of pacemaker implantation and removal. In: Ellenbogen KA, Wood MA, eds. Cardiac pacing and ICDs. 4th edition. Oxford, MA: Blackwell Publishing, 2005: 231-263
    • (2005) Cardiac Pacing and ICDs. 4th Edition , pp. 231-263
    • Brinker, J.1    Midei, M.G.2
  • 2
    • 0032082605 scopus 로고    scopus 로고
    • Complications of dual chamber pacemaker implantation in the elderly
    • Pacemaker Selection in the Elderly (PASE) Investigators
    • Link MS, Estes NA 3rd, Griffin JJ, et al. Complications of dual chamber pacemaker implantation in the elderly. Pacemaker Selection in the Elderly (PASE) Investigators. J Interv Card Electrophysiol 1998; 2: 175-179
    • (1998) J Interv Card Electrophysiol , vol.2 , pp. 175-179
    • Link, M.S.1    Estes III, N.A.2    Griffin, J.J.3
  • 3
    • 0034654472 scopus 로고    scopus 로고
    • Acute complications of permanent pacemaker implantation: Their financial implication and relation to volume and operator experience
    • DOI 10.1016/S0002-9149(99)00861-9, PII S0002914999008619
    • Tobin K, Stewart J, Westveer D, Frumin H. Acute complications of permanent pacemaker implantation: their financial implication and relation to volume and operator experience. Am J Cardiol 2000; 85: 774-776 (Pubitemid 30133406)
    • (2000) American Journal of Cardiology , vol.85 , Issue.6 , pp. 774-776
    • Tobin, K.1    Stewart, J.2    Westveer, D.3    Frumin, H.4
  • 7
    • 0032423829 scopus 로고    scopus 로고
    • Internal balloon compression: A method to achieve hemostasis when removing an inadvertently placed pacemaker lead from the subclavian artery
    • DOI 10.1111/j.1540-8159.1998.tb00046.x
    • Oude Ophuis AJ, van Doorn DJ, van Ommen VA, den Dulk K, Wellens HJ. Internal balloon compression: a method to achieve hemostasis when removing an inadvertently placed pacemaker lead from the subclavian artery. Pacing Clin Electrophysiol 1998; 21: 2673-2676 (Pubitemid 29031414)
    • (1998) PACE - Pacing and Clinical Electrophysiology , vol.21 , Issue.12 , pp. 2673-2676
    • Oude Ophuis, A.J.M.1    Van Doorn, D.J.2    Van Ommen, V.A.3    Den Dulk, K.4    Wellens, H.J.J.5
  • 9
    • 0014076915 scopus 로고
    • Air embolism to the pulmonary artery during insertion of transvenous endocardial pacemaker
    • Rotem CE, Greig JH, Walters MB. Air embolism to the pulmonary artery during insertion of transvenous endocardial pacemaker. J Thorac Cardiovasc Surg 1967; 53: 562-565
    • (1967) J Thorac Cardiovasc Surg , vol.53 , pp. 562-565
    • Rotem, C.E.1    Greig, J.H.2    Walters, M.B.3
  • 10
    • 0028142539 scopus 로고
    • Clinical surveillance of an active fixation, bipolar, polyurethane insulated pacing lead, Part I: The atrial lead
    • DOI 10.1111/j.1540-8159.1994.tb02459.x
    • Glikson M, von Feldt LK, Suman VJ, Hayes DL. Clinical surveillance of an active fixation, bipolar, polyurethane insulated pacing lead. Part I: The atrial lead. Pacing Clin Electrophysiol 1994; 17: 1399-1404 (Pubitemid 24243386)
    • (1994) PACE - Pacing and Clinical Electrophysiology , vol.17 , Issue.8 , pp. 1399-1404
    • Glikson, M.1    Von Feldt, L.K.2    Suman, V.J.3    Hayes, D.L.4
  • 11
    • 0014561809 scopus 로고
    • Electrocardiographic diagnosis of perforation of the heart by pacing catheter electrode
    • Barold SS, Center S. Electrocardiographic diagnosis of perforation of the heart by pacing catheter electrode. Am J Cardiol 1969; 24: 274-278
    • (1969) Am J Cardiol , vol.24 , pp. 274-278
    • Barold, S.S.1    Center, S.2
  • 14
    • 6344254774 scopus 로고    scopus 로고
    • Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: Influence of patient morbidity, operation strategy, and perioperative antiplatelet/anticoagulation therapy
    • DOI 10.1378/chest.126.4.1177
    • Wiegand UK, LeJeune D, Boguschewski F, et al. Pocket hematoma after pacemaker or implantable cardioverter defibrillator surgery: influence of patient morbidity, operation strategy, and perioperative antiplatelet/ anticoagulation therapy. Chest 2004; 126: 1177-1186 (Pubitemid 39391248)
    • (2004) Chest , vol.126 , Issue.4 , pp. 1177-1186
    • Wiegand, U.K.H.1    Lejeune, D.2    Boguschewski, F.3    Bonnemeier, H.4    Eberhardt, F.5    Schunkert, H.6    Bode, F.7
  • 15
    • 0031840199 scopus 로고    scopus 로고
    • Long-term thrombosis after transvenous permanent pacemaker implantation
    • DOI 10.1111/j.1540-8159.1998.tb00177.x
    • Goto Y, Abe T, Sekine S, Sakurada T. Long-term thrombosis after transvenous permanent pacemaker implantation. Pacing Clin Electrophysiol 1998; 21: 1192-1195 (Pubitemid 28270050)
    • (1998) PACE - Pacing and Clinical Electrophysiology , vol.21 , Issue.6 , pp. 1192-1195
    • Goto, Y.1    Abe, T.2    Sekine, S.3    Sakurada, T.4
  • 16
    • 0032437885 scopus 로고    scopus 로고
    • Assessment of the subclavian vein in patients with transvenous pacemaker leads
    • DOI 10.1111/j.1540-8159.1998.tb00039.x
    • Zuber M, Huber P, Fricker U, Buser P, Jager K. Assessment of the subclavian vein in patients with transvenous pacemaker leads. Pacing Clin Electrophysiol 1998; 21: 2621-2630 (Pubitemid 29031408)
    • (1998) PACE - Pacing and Clinical Electrophysiology , vol.21 , Issue.12 , pp. 2621-2630
    • Zuber, M.1    Huber, P.2    Fricker, U.3    Buser, P.4    Jager, K.5
  • 17
    • 0036855350 scopus 로고    scopus 로고
    • The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads
    • Oginosawa Y, Abe H, Nakashima Y. The incidence and risk factors for venous obstruction after implantation of transvenous pacing leads. Pacing Clin Electrophysiol 2002; 25: 1605-1611 (Pubitemid 35398922)
    • (2002) PACE - Pacing and Clinical Electrophysiology , vol.25 , Issue.11 , pp. 1605-1611
    • Oginosawa, Y.1    Abe, H.2    Nakashima, Y.3
  • 18
    • 0014428609 scopus 로고
    • The pacemaker-Twiddler's syndrome: A new complication of implantable transvenous pacemakers
    • Bayliss CE, Beanlands DS, Baird RJ. The pacemaker-Twiddler's syndrome: a new complication of implantable transvenous pacemakers. Can Med Assoc J 1968; 99: 371-373
    • (1968) Can Med Assoc J , vol.99 , pp. 371-373
    • Bayliss, C.E.1    Beanlands, D.S.2    Baird, R.J.3
  • 19
    • 0036741233 scopus 로고    scopus 로고
    • Interference in implanted cardiac devices. Part I
    • Completa ed esaustiva rassegna circa le potenziali interferenze tra sorgenti esogene e dispositivi elettrici impiantabili
    • Pinski SL, Trohman RG. Interference in implanted cardiac devices. Part I. Pacing Clin Electrophysiol 2002; 25: 1367-1381 Completa ed esaustiva rassegna circa le potenziali interferenze tra sorgenti esogene e dispositivi elettrici impiantabili.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1367-1381
    • Pinski, S.L.1    Trohman, R.G.2
  • 21
    • 33646164892 scopus 로고    scopus 로고
    • Pacemaker and ICD generator malfunctions: Analysis of Food and Drug Administration annual reports
    • Accurate analisi retrospettiva dei report relativi al malfunzionamento di pacemaker e defibrillatori impiantabili comunicata dalle ditte produttrici alla Food and Drug Administration nel periodo 1990-2002
    • Maisel WH, Moynahan M, Zuckerman BD, et al. Pacemaker and ICD generator malfunctions: analysis of Food and Drug Administration annual reports. JAMA 2006; 295: 1901-6. Accurate analisi retrospettiva dei report relativi al malfunzionamento di pacemaker e defibrillatori impiantabili comunicata dalle ditte produttrici alla Food and Drug Administration nel periodo 1990-2002.
    • (2006) JAMA , vol.295 , pp. 1901-1906
    • Maisel, W.H.1    Moynahan, M.2    Zuckerman, B.D.3
  • 22
    • 33746430581 scopus 로고    scopus 로고
    • Management of recalled pacemakers and implantable cardioverter- Defibrillators a decision analysis model
    • DOI 10.1001/jama.296.4.412
    • Amin MS, Matchar DB, Wood MA, Ellenbogen KA. Management of recalled pacemakers and implantable cardioverter-defibrillators: a decision analysis model. JAMA 2006; 296: 412-20. (Pubitemid 44127525)
    • (2006) Journal of the American Medical Association , vol.296 , Issue.4 , pp. 412-420
    • Amin, M.S.1    Matchar, D.B.2    Wood, M.A.3    Ellenbogen, K.A.4
  • 23
    • 0032510664 scopus 로고    scopus 로고
    • Antibiotic prophylaxis for permanent pacemaker implantation: A meta- Analysis
    • Da Costa A, Kirkorian G, Cucherat M, et al. Antibiotic prophylaxis for permanent pacemaker implantation: a meta-analysis. Circulation 1998; 97: 1796-1801 Metanalisi dei principali trial relativi all'utilizzo della profilassi antibiotica in corso di impianto di pacemaker. (Pubitemid 28213623)
    • (1998) Circulation , vol.97 , Issue.18 , pp. 1796-1801
    • Da Costa, A.1    Kirkorian, G.2    Cucherat, M.3    Delahaye, F.4    Chevalier, P.5    Cerisier, A.6    Isaaz, K.7    Touboul, P.8
  • 24
    • 0037176263 scopus 로고    scopus 로고
    • Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: The Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial
    • for the DAVID Investigators
    • Wilkoff BL, Cook JR, Epstein AE, et al, for the DAVID Investigators. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the Dual Chamber and VVI Implantable Defibrillator (DAVID) Trial. JAMA 2002; 288: 3115-3123
    • (2002) JAMA , vol.288 , pp. 3115-3123
    • Wilkoff, B.L.1    Cook, J.R.2    Epstein, A.E.3
  • 25
    • 20144387118 scopus 로고    scopus 로고
    • The clinical implications of cumulative right ventricular pacing in the multicenter automatic defibrillator trial II
    • for the MADIT II Investigators
    • Steinberg JS, Fischer A, Wang P, et al, for the MADIT II Investigators. The clinical implications of cumulative right ventricular pacing in the multicenter automatic defibrillator trial II. J Cardiovasc Electrophysiol 2005; 16: 359-365
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 359-365
    • Steinberg, J.S.1    Fischer, A.2    Wang, P.3
  • 26
    • 84882874365 scopus 로고    scopus 로고
    • Management of device related infections
    • Ellenbogen KA, Wilkoff BL, Kay GN, Lau CP, eds. Philadelphia, PA: Saunders-Elsevier
    • Byrd CL. Management of device related infections. In: Ellenbogen KA, Wilkoff BL, Kay GN, Lau CP, eds. Clinical cardiac pacing, defibrillation and resynchronization therapy. Philadelphia, PA: Saunders-Elsevier, 2007: 855-930.
    • (2007) Clinical Cardiac Pacing, Defibrillation and Resynchronization Therapy , pp. 855-930
    • Byrd, C.L.1
  • 32
    • 57349111725 scopus 로고    scopus 로고
    • Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: High success rate and safety in more than 2000 leads
    • Analisi retrospettiva di una delle più importanti esperienze internazionali circa l'utilizzo della tecnica meccanica di rimozione transvenosa di elettrocateteri da stimolazione e defibrillazione
    • Bongiorni MG, Soldati E, Zucchelli G, et al. Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads. Eur Heart J 2008; 29: 2886-2893 Analisi retrospettiva di una delle più importanti esperienze internazionali circa l'utilizzo della tecnica meccanica di rimozione transvenosa di elettrocateteri da stimolazione e defibrillazione.
    • (2008) Eur Heart J , vol.29 , pp. 2886-2893
    • Bongiorni, M.G.1    Soldati, E.2    Zucchelli, G.3
  • 33
    • 22344448594 scopus 로고    scopus 로고
    • Pacing and implantable cardioverter-defibrillator transvenous lead extraction
    • Bongiorni MG, Giannola G, Arena G, et al. Pacing and implantable cardioverter-defibrillator transvenous lead extraction. Ital Heart J 2005; 6: 261-266
    • (2005) Ital Heart J , vol.6 , pp. 261-266
    • Bongiorni, M.G.1    Giannola, G.2    Arena, G.3
  • 35
    • 34548695954 scopus 로고    scopus 로고
    • Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: Results of a large prospective study
    • for the PEOPLE Study Group
    • Klug D, Balde M, Pavin D, et al, for the PEOPLE Study Group. Risk factors related to infections of implanted pacemakers and cardioverter-defibrillators: results of a large prospective study. Circulation 2007; 116: 1349-1355
    • (2007) Circulation , vol.116 , pp. 1349-1355
    • Klug, D.1    Balde, M.2    Pavin, D.3
  • 36
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • for the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators
    • Bardy GH, Lee KL, Mark DB, et al, for the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT) Investigators. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005; 352: 225-237
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 37
    • 3343001221 scopus 로고    scopus 로고
    • Cost-effectiveness of primary implanted cardioverter defibrillator for sudden death prevention in congestive heart failure
    • DOI 10.1023/B:CARD.0000029034.65769.f7
    • Chen L, Hay JW. Cost-effectiveness of primary implanted cardioverter defibrillator for sudden death prevention in congestive heart failure. Cardiovasc Drugs Ther 2004; 18: 161-170 (Pubitemid 38987363)
    • (2004) Cardiovascular Drugs and Therapy , vol.18 , Issue.2 , pp. 161-170
    • Chen, L.1    Hay, J.W.2
  • 41
    • 41149165849 scopus 로고    scopus 로고
    • Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: Frequency, mechanisms, predictors, and survival impact
    • for the MADIT II Investigators
    • Daubert JP, Zareba W, Cannom DS, et al, for the MADIT II Investigators. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol 2008; 51: 1357-1365
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1357-1365
    • Daubert, J.P.1    Zareba, W.2    Cannom, D.S.3
  • 42
    • 26444431999 scopus 로고    scopus 로고
    • Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: Combined results of over 2000 patients from a multicenter study program
    • for the MIRACLE Study Program
    • Leon AR, Abraham WT, Curtis AB, et al, for the MIRACLE Study Program. Safety of transvenous cardiac resynchronization system implantation in patients with chronic heart failure: combined results of over 2000 patients from a multicenter study program. J Am Coll Cardiol 2005; 46: 2348-2356
    • (2005) J Am Coll Cardiol , vol.46 , pp. 2348-2356
    • Leon, A.R.1    Abraham, W.T.2    Curtis, A.B.3
  • 43
    • 11144324879 scopus 로고    scopus 로고
    • Clinical assessment and management of patients with implanted cardioverter-defibrillators presenting to nonelectrophysiologists
    • for the Subcommittee on Electrocardiography and Arrhythmias of the American Heart Association Council on Clinical Cardiology; Heart Rhythm Society
    • Stevenson WG, Chiatman BR, Ellenbogen KA, et al, for the Subcommittee on Electrocardiography and Arrhythmias of the American Heart Association Council on Clinical Cardiology; Heart Rhythm Society. Clinical assessment and management of patients with implanted cardioverter-defibrillators presenting to nonelectrophysiologists. Circulation 2004; 110: 3866-3869
    • (2004) Circulation , vol.110 , pp. 3866-3869
    • Stevenson, W.G.1    Chiatman, B.R.2    Ellenbogen, K.A.3
  • 46
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • for the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators
    • Bristow MR, Saxon LA, Boehmer J, et al, for the Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 2004; 350: 2140-2150
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.