Volumn , Issue , 2008, Pages 2970-2975

XAMPS detector readout ASIC for LCLS

Author keywords

[No Author keywords available]

Indexed keywords

ACTIVE MATRIX PIXELS; ANALOG MEMORIES; ASIC ARCHITECTURE; BALANCE MEASUREMENT; CHARGE PUMP; CORRELATED DOUBLE SAMPLING; DETECTOR READOUT; DIGITAL CONVERSION; DYNAMIC RANGE; INPUT CAPACITANCE; INTEGRATED CHARGE; LINAC COHERENT LIGHT SOURCE; LOW NOISE; NOISE OPTIMIZATION; ON CHIPS; POSITION RESOLUTION; PUMP PROBE; RESIDUAL CHARGE; SINGLE PIXEL; STRINGENT REQUIREMENT; TIME VARIANT SYSTEMS;

EID: 67649233023     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774986     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 67649177946 scopus 로고    scopus 로고
    • http://lcls.slac.stanford.edu/xpp/
  • 2
    • 49649138161 scopus 로고
    • Trapezoidal filtering of signals from large germanium detectors at high rates
    • V. Radeka, "Trapezoidal filtering of signals from large germanium detectors at high rates," Nucl. lustrum. Methods, 99, pp. 525-539, 1972.
    • (1972) Nucl. lustrum. Methods , vol.99 , pp. 525-539
    • Radeka, V.1
  • 4
    • 48349111342 scopus 로고    scopus 로고
    • Development of x-ray active matrix pixel sensors based on J-FET technology for the linac coherent light source
    • G. A. Carini, W. Chen, Z. Li, P. Rehak, D. P. Siddons, " Development of X-ray Active Matrix Pixel Sensors based on J-FET technology for the Linac Coherent Light Source", IEEE Nuclear Science Symposium Conference Record, 2007, 2, 1603-1606.
    • (2007) IEEE Nuclear Science Symposium Conference Record , vol.2 , pp. 1603-1606
    • Carini, G.A.1    Chen, W.2    Li, Z.3    Rehak, P.4    Siddons, D.P.5
  • 6
    • 0142063476 scopus 로고    scopus 로고
    • Theoretical comparison between two different filtering techniques suitable for the VLSI spectroscopic amplifier ROTOR
    • M. Porro, C. Fiorini, L. Striider, "Theoretical comparison between two different filtering techniques suitable for the VLSI spectroscopic amplifier ROTOR," Nucl. Instrum. Methods, A512, pp. 179-190, 2003.
    • (2003) Nucl. Instrum. Methods , vol.A512 , pp. 179-190
    • Porro, M.1    Fiorini, C.2    Striider, L.3
  • 7
    • 0001129520 scopus 로고
    • Low noise techniques in detectors
    • V. Radeka, "Low Noise Techniques in Detectors," Ann. Rev. Nucl. Part. Sci. Methods, 1988, 38, pp. 217-277.
    • (1988) Ann. Rev. Nucl. Part. Sci. Methods , vol.38 , pp. 217-277
    • Radeka, V.1
  • 8
    • 27644568954 scopus 로고    scopus 로고
    • A 64-channel wide dynamic range charge measurement ASIC for strip and pixel ionization detectors
    • G. Mazza et al., "A 64-Channel Wide Dynamic Range Charge Measurement ASIC for Strip and Pixel Ionization Detectors", IEEE Trans. Nucl. Sci. NS-52 (2005) (4), p. 847.
    • (2005) IEEE Trans. Nucl. Sci. , vol.NS-52 , Issue.4 , pp. 847
    • Mazza, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.