Suspensory Fixation of Grafts in Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison of 3 Implants

Author keywords

Anterior cruciate ligament reconstruction; EndoButton CL; Knee; RetroButton; Suspensory fixation; ToggleLoc

Indexed keywords

ANIMAL TISSUE; ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION; ARTICLE; BIOMECHANICS; CONTROLLED STUDY; IMPLANTATION; LIGAMENT PROSTHESIS; MATERIALS TESTING; NONHUMAN; PROSTHESIS FAILURE; PROSTHESIS FIXATION; PROSTHESIS MATERIAL; SWINE;

EID: 67649227128     PISSN: 07498063     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.arthro.2009.01.021     Document Type: Article
Times cited : (85)

References (21)
  • 2
    • 0032245391 scopus 로고    scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament reconstruction: Fact or fiction?
    • Höher J., Möller H.D., and Fu F.H. Bone tunnel enlargement after anterior cruciate ligament reconstruction: Fact or fiction?. Knee Surg Sports Traumatol Arthrosc 6 (1998) 231-240
    • (1998) Knee Surg Sports Traumatol Arthrosc , vol.6 , pp. 231-240
    • Höher, J.1    Möller, H.D.2    Fu, F.H.3
  • 3
    • 0038558473 scopus 로고    scopus 로고
    • The effect of outlet fixation on tunnel widening
    • Barber F.A., Spruill B., and Sheluga M. The effect of outlet fixation on tunnel widening. Arthroscopy 19 (2003) 485-492
    • (2003) Arthroscopy , vol.19 , pp. 485-492
    • Barber, F.A.1    Spruill, B.2    Sheluga, M.3
  • 4
    • 33750963484 scopus 로고    scopus 로고
    • Tendon healing in a bone tunnel differs at the tunnel entrance versus the tunnel exit: An effect of graft-tunnel motion?
    • Rodeo S.A., Kawamura S., Kim H.J., Dynybil C., and Ying L. Tendon healing in a bone tunnel differs at the tunnel entrance versus the tunnel exit: An effect of graft-tunnel motion?. Am J Sports Med 34 (2006) 1790-1800
    • (2006) Am J Sports Med , vol.34 , pp. 1790-1800
    • Rodeo, S.A.1    Kawamura, S.2    Kim, H.J.3    Dynybil, C.4    Ying, L.5
  • 6
    • 33750440784 scopus 로고    scopus 로고
    • Hybrid femoral fixation of soft-tissue grafts in anterior cruciate ligament reconstruction using the EndoButton CL and bioabsorbable interference screws: A biomechanical study
    • Oh Y.H., Namkoong S., Strauss E.J., et al. Hybrid femoral fixation of soft-tissue grafts in anterior cruciate ligament reconstruction using the EndoButton CL and bioabsorbable interference screws: A biomechanical study. Arthroscopy 22 (2006) 1218-1224
    • (2006) Arthroscopy , vol.22 , pp. 1218-1224
    • Oh, Y.H.1    Namkoong, S.2    Strauss, E.J.3
  • 7
    • 33645860498 scopus 로고    scopus 로고
    • Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: An in vitro animal study
    • Espejo-Baena A., Ezquerro F., de la Blanca A.P., Serrano-Fernandez J., Nadal F., and Montañez-Heredia E. Comparison of initial mechanical properties of 4 hamstring graft femoral fixation systems using nonpermanent hardware for anterior cruciate ligament reconstruction: An in vitro animal study. Arthroscopy 22 (2006) 433-440
    • (2006) Arthroscopy , vol.22 , pp. 433-440
    • Espejo-Baena, A.1    Ezquerro, F.2    de la Blanca, A.P.3    Serrano-Fernandez, J.4    Nadal, F.5    Montañez-Heredia, E.6
  • 8
    • 0036892598 scopus 로고    scopus 로고
    • The effect of initial graft tension in anterior cruciate ligament reconstruction on the mechanical behaviors of the femur-graft-tibia complex during cyclic loading
    • Numazaki H., Tohyama H., Nakano H., Kikuchi S., and Yasuda K. The effect of initial graft tension in anterior cruciate ligament reconstruction on the mechanical behaviors of the femur-graft-tibia complex during cyclic loading. Am J Sports Med 30 (2002) 800-805
    • (2002) Am J Sports Med , vol.30 , pp. 800-805
    • Numazaki, H.1    Tohyama, H.2    Nakano, H.3    Kikuchi, S.4    Yasuda, K.5
  • 9
    • 0002618771 scopus 로고    scopus 로고
    • In vitro testing protocols for the cruciate ligaments and ligament reconstructions
    • Beynnon B.D., and Amis A.A. In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg Sports Traumatol Arthrosc 6 (1998) 70-76
    • (1998) Knee Surg Sports Traumatol Arthrosc , vol.6 , pp. 70-76
    • Beynnon, B.D.1    Amis, A.A.2
  • 10
    • 7544243356 scopus 로고    scopus 로고
    • Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading
    • Brown C.H., Wilson D.R., Hecker A.T., and Ferragamo M. Graft-bone motion and tensile properties of hamstring and patellar tendon anterior cruciate ligament femoral graft fixation under cyclic loading. Arthroscopy 20 (2004) 922-935
    • (2004) Arthroscopy , vol.20 , pp. 922-935
    • Brown, C.H.1    Wilson, D.R.2    Hecker, A.T.3    Ferragamo, M.4
  • 11
    • 0037347246 scopus 로고    scopus 로고
    • The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: Femoral site
    • Kousa P., Järvinen T., Vihavainen M., Kannus P., and Järvinen M. The fixation strength of six hamstring tendon graft fixation devices in anterior cruciate ligament reconstruction. Part I: Femoral site. Am J Sports Med 31 (2003) 174-181
    • (2003) Am J Sports Med , vol.31 , pp. 174-181
    • Kousa, P.1    Järvinen, T.2    Vihavainen, M.3    Kannus, P.4    Järvinen, M.5
  • 12
    • 1942439016 scopus 로고    scopus 로고
    • Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction
    • Ahmad C.S., Gardner T.R., Groh M., Arnouk J., and Levine W.N. Mechanical properties of soft tissue femoral fixation devices for anterior cruciate ligament reconstruction. Am J Sports Med 32 (2004) 635-640
    • (2004) Am J Sports Med , vol.32 , pp. 635-640
    • Ahmad, C.S.1    Gardner, T.R.2    Groh, M.3    Arnouk, J.4    Levine, W.N.5
  • 13
    • 23244450983 scopus 로고    scopus 로고
    • Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts
    • Zantop T., Ruemmler M., Welbes B., Langer M., Weimann A., and Petersen W. Cyclic loading comparison between biodegradable interference screw fixation and biodegradable double cross-pin fixation of human bone-patellar tendon-bone grafts. Arthroscopy 21 (2005) 934-941
    • (2005) Arthroscopy , vol.21 , pp. 934-941
    • Zantop, T.1    Ruemmler, M.2    Welbes, B.3    Langer, M.4    Weimann, A.5    Petersen, W.6
  • 15
    • 0021337787 scopus 로고
    • Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions
    • Noyes F.R., Butler D.L., Grood E.S., Zernicke R.F., and Hefzy M.S. Biomechanical analysis of human ligament grafts used in knee-ligament repairs and reconstructions. J Bone Joint Surg Am 66 (1984) 344-352
    • (1984) J Bone Joint Surg Am , vol.66 , pp. 344-352
    • Noyes, F.R.1    Butler, D.L.2    Grood, E.S.3    Zernicke, R.F.4    Hefzy, M.S.5
  • 16
    • 0031309423 scopus 로고    scopus 로고
    • Tunnel expansion following anterior cruciate ligament reconstruction: A comparison of hamstring and patellar tendon autografts
    • L'Insalata J.C., Klatt B., Fu F.H., and Harner C.D. Tunnel expansion following anterior cruciate ligament reconstruction: A comparison of hamstring and patellar tendon autografts. Knee Surg Sports Traumatol Arthrosc 5 (1997) 234-238
    • (1997) Knee Surg Sports Traumatol Arthrosc , vol.5 , pp. 234-238
    • L'Insalata, J.C.1    Klatt, B.2    Fu, F.H.3    Harner, C.D.4
  • 17
    • 0031741691 scopus 로고    scopus 로고
    • Bone tunnel enlargement after anterior cruciate ligament reconstruction with semitendinosus tendon using EndoButton fixation on the femoral side
    • Nebelung W., Becker R., Merkel M., and Ropke M. Bone tunnel enlargement after anterior cruciate ligament reconstruction with semitendinosus tendon using EndoButton fixation on the femoral side. Arthroscopy 14 (1998) 810-815
    • (1998) Arthroscopy , vol.14 , pp. 810-815
    • Nebelung, W.1    Becker, R.2    Merkel, M.3    Ropke, M.4
  • 18
    • 56749185601 scopus 로고    scopus 로고
    • Tunnel widening following anterior cruciate ligament reconstruction using hamstring autograft: A comparison between double cross-pin and suspensory graft fixation
    • Baumfeld J.A., Diduch D.R., Rubino L.J., et al. Tunnel widening following anterior cruciate ligament reconstruction using hamstring autograft: A comparison between double cross-pin and suspensory graft fixation. Knee Surg Sports Traumatol Arthrosc 16 (2008) 1108-1113
    • (2008) Knee Surg Sports Traumatol Arthrosc , vol.16 , pp. 1108-1113
    • Baumfeld, J.A.1    Diduch, D.R.2    Rubino, L.J.3
  • 19
    • 0036514822 scopus 로고    scopus 로고
    • A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: Extracortical versus anatomical fixation
    • Buelow J.U., Siebold R., and Ellermann A. A prospective evaluation of tunnel enlargement in anterior cruciate ligament reconstruction with hamstrings: Extracortical versus anatomical fixation. Knee Surg Sports Traumatol Arthrosc 10 (2002) 80-85
    • (2002) Knee Surg Sports Traumatol Arthrosc , vol.10 , pp. 80-85
    • Buelow, J.U.1    Siebold, R.2    Ellermann, A.3
  • 20
    • 0032950678 scopus 로고    scopus 로고
    • Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts
    • Magen H.E., Howell S.M., and Hull M.L. Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am J Sports Med 27 (1999) 23-43
    • (1999) Am J Sports Med , vol.27 , pp. 23-43
    • Magen, H.E.1    Howell, S.M.2    Hull, M.L.3
  • 21
    • 33744537058 scopus 로고    scopus 로고
    • Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft. A biomechanical analysis
    • Milano G., Mulas P.D., Ziranu F., Piras S., Manunta A., and Fabbriciani C. Comparison between different femoral fixation devices for ACL reconstruction with doubled hamstring tendon graft. A biomechanical analysis. Arthroscopy 22 (2006) 660-668
    • (2006) Arthroscopy , vol.22 , pp. 660-668
    • Milano, G.1    Mulas, P.D.2    Ziranu, F.3    Piras, S.4    Manunta, A.5    Fabbriciani, C.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.