메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3596-3603

Study of a high resolution, 3-D positioning cross strip cadmium zinc telluride detector for PET

Author keywords

[No Author keywords available]

Indexed keywords

CADMIUM ZINC TELLURIDE DETECTORS; CHARGE COLLECTION; COLLIMATED BEAMS; CROSS-STRIP; DETECTOR CONCEPTS; ELECTRONIC COLLIMATION; ENERGY RESOLUTIONS; EXCELLENT PERFORMANCE; FRONT END ELECTRONIC; HIGH RESOLUTION; HIGH-RESOLUTION PET; PHOTON INTERACTIONS; SINGLE-ANODE; SPATIAL RESOLUTION; ULTRAHIGH RESOLUTION;

EID: 67649220127     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774098     Document Type: Conference Paper
Times cited : (7)

References (5)
  • 1
    • 48149096565 scopus 로고    scopus 로고
    • Accurately positioning events in a high resolution PET system that uses 3D CZT detectors
    • NSS '07. IEEE,Oct. 26 2007-Nov. 3 2007
    • G. Pratx and S. Levin, "Accurately Positioning Events in a HighResolution PET System That Uses 3D CZT Detectors", Nuclear Science Symposium Conference Record. 2007. NSS '07. IEEE, Vol 4, Oct. 26 2007-Nov. 3 2007 Page(s):2660 - 2664.
    • Nuclear Science Symposium Conference Record. 2007 , pp. 2660-2664
    • Pratx, G.1    Levin, C.S.2
  • 2
    • 60549086345 scopus 로고    scopus 로고
    • New imaging technologies to enhance the molecular sensitivity of positron emission tomography
    • March
    • S. Levin, "New Imaging Technologies to Enhance the Molecular Sensitivity of Positron Emission Tomography", Proceedings of the IEEE, Vol 96, Iss 3, March 2008 Pages: 439-467.
    • (2008) Proceedings of the IEEE , vol.96 , Issue.3 , pp. 439-467
    • Levin, C.S.1
  • 3
    • 67649153807 scopus 로고    scopus 로고
    • Effects of multiple photon interactions in a high resolution PET system that uses 3-D positioning detectors
    • MIC '08. IEEE,submitted for publication
    • Y. Gu, G Pratx, and S. Levin, " Effects of Multiple Photon Interactions in a High Resolution PET System that Uses 3-D Positioning Detectors" Medical Imaging Conference Record, 200R. MI(' •OR. IEEE, submitted for publication.
    • Medical Imaging Conference Record, 2008
    • Gu, Y.1    Pratx, G.2    Levin, C.S.3
  • 5
    • 85076821068 scopus 로고    scopus 로고
    • CZT detectors with 3-D readout for gamma-ray spectroscopy and imaging
    • Matteson, "CZT detectors with 3-D readout for gamma-ray spectroscopy and imaging", Proc. SPIE, Vol 4784, 2002.
    • (2002) Proc. SPIE , vol.4784
    • Matteson, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.