메뉴 건너뛰기




Volumn 18, Issue 3, 2009, Pages 189-204

Response coefficient: A new concept to evaluate ventilation performance with ''pulse'' boundary conditions

Author keywords

Air distribution; Evaluation index; Indoor air quality (IAQ); Passive contaminant; Ventilation efficiency

Indexed keywords

AIR CONDITIONING; AIR MONITORING; AIR POLLUTION; AIRFLOW; AMBIENT AIR; ARTICLE; INDOOR AIR POLLUTION; MATHEMATICAL ANALYSIS; PRIORITY JOURNAL; ROOM VENTILATION;

EID: 67649211315     PISSN: 1420326X     EISSN: 14230070     Source Type: Journal    
DOI: 10.1177/1420326X09104345     Document Type: Article
Times cited : (14)

References (25)
  • 1
    • 0024020434 scopus 로고    scopus 로고
    • Human exposure to carbon monoxide and inhalable particulate in Beijing
    • Wang JN, Cao SR, Li Z., Zhang Y., Li SM: Human exposure to carbon monoxide and inhalable particulate in Beijing. China: Biomed Environ Sci 1998 ; 1 (1). 5-12.
    • (1998) China: Biomed Environ Sci , vol.1 , Issue.1 , pp. 5-12
    • Wang, J.N.1    Cao, S.R.2    Li, Z.3    Zhang, Y.4    Li, S.M.5
  • 4
    • 1342316138 scopus 로고    scopus 로고
    • Human requirements in future air conditioned environments: A search for excellence
    • Fanger PO: Human requirements in future air conditioned environments: a search for excellence: In Proc. 3rd ISHVAC, Shenzhen, 1999, pp. 86-92.
    • Proc. 3rd ISHVAC
    • Fanger, P.O.1
  • 5
    • 0036712573 scopus 로고    scopus 로고
    • Personalized ventilation: Evaluation of different air terminal devices
    • DOI 10.1016/S0378-7788(02)00102-0, PII S0378778802001020
    • Melikov AK, Cermak R., Mayer M.: Personalized ventilation: evaluation of different air terminal devices: Energy and Buildings 2002 ; 34 (8). 829-836. (Pubitemid 34991451)
    • (2002) Energy and Buildings , vol.34 , Issue.8 , pp. 829-836
    • Melikov, A.K.1    Cermak, R.2    Majer, M.3
  • 6
    • 0030313973 scopus 로고    scopus 로고
    • Room air and contaminant distribution in mixing ventilation
    • Heiselberg P.: Room air and contaminant distribution in mixing ventilation ASHRAE Trans 1996 ; 102 (2). 332-339.
    • (1996) ASHRAE Trans , vol.102 , Issue.2 , pp. 332-339
    • Heiselberg, P.1
  • 7
    • 0020940765 scopus 로고
    • USE OF MOMENTS FOR ASSESSING AIR QUALITY IN VENTILATED ROOMS.
    • DOI 10.1016/0360-1323(83)90026-4
    • Sandberg M., Sjoberg M.: The use of moments for assessing air quality in ventilated rooms: Building Environ 1983 ; 18 (4). 181-197. (Pubitemid 14508271)
    • (1983) Building and Environment , vol.18 , Issue.4 , pp. 181-197
    • Sandberg Mats1    Sjoberg Mats2
  • 11
    • 0026897785 scopus 로고
    • Computational fluid dynamics for building air flow prediction- current status and capabilities
    • Jones PJ, Whittle GE: Computational fluid dynamics for building air flow prediction- current status and capabilities: Building Environ 1992 ; 27 (3). 321-328.
    • (1992) Building Environ , vol.27 , Issue.3 , pp. 321-328
    • Jones, P.J.1    Whittle, G.E.2
  • 12
    • 1542742104 scopus 로고    scopus 로고
    • Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility
    • Yang JR, Li XT, Zhao B.: Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility: Energy Buildings. 2004 ; 36 (3). 293-299.
    • (2004) Energy Buildings , vol.36 , Issue.3 , pp. 293-299
    • Yang, J.R.1    Li, X.T.2    Zhao, B.3
  • 13
    • 0020940765 scopus 로고
    • USE OF MOMENTS FOR ASSESSING AIR QUALITY IN VENTILATED ROOMS.
    • DOI 10.1016/0360-1323(83)90026-4
    • Sandberg M., Sjoberg M.: The use of moments for assessing air quality in ventilated rooms: Building Environ 1983 ; 18: 181-197. (Pubitemid 14508271)
    • (1983) Building and Environment , vol.18 , Issue.4 , pp. 181-197
    • Sandberg Mats1    Sjoberg Mats2
  • 14
    • 0020944408 scopus 로고
    • VENTILATION EFFICIENCY AS A GUIDE TO DESIGN.
    • Sandberg M.: Ventilation efficiency as a guide to design: ASHRAE Trans 1983 ; 89 (2B). 455-479. (Pubitemid 14500705)
    • (1983) ASHRAE Transactions , vol.89 , Issue.PT 2B , pp. 455-479
    • Sandberg Mats1
  • 15
    • 0037520575 scopus 로고    scopus 로고
    • New scales for ventilation efficiency and their application based on numerical simulation of room airflow
    • Murakami S.: New scales for ventilation efficiency and their application based on numerical simulation of room airflow: In Proc. Intl Symp Room Air Convention and Ventilation Effectiveness. University of Tokyo, July 22-24, 1992, pp. 22-38.
    • Proc. Intl Symp Room Air Convention and Ventilation Effectiveness
    • Murakami, S.1
  • 17
    • 4143080606 scopus 로고    scopus 로고
    • Accessibility: A new concept to evaluate ventilation performance in a finite period of time
    • DOI 10.1177/1420326X04045440
    • Li XT, Zhao B.: Accessibility: a new concept to evaluate ventilation performance in a finite period of time: Indoor Built Environ 2004 ; 13: 287-293. (Pubitemid 39093552)
    • (2004) Indoor and Built Environment , vol.13 , Issue.4 , pp. 287-293
    • Li, X.1    Zhao, B.2
  • 20
    • 0036457789 scopus 로고    scopus 로고
    • Numerical simulation of air distribution in chair ventilated rooms by simplified methodology
    • Zhao B., Li XT, Lu JJ: Numerical simulation of air distribution in chair ventilated room by simplified methodology: ASHRAE Trans. 2002 ; 108: 1079-1083. (Pubitemid 35475766)
    • (2002) ASHRAE Transactions , vol.108 PART 2 , pp. 1079-1083
    • Zhao, B.1    Li, X.2    Lu, J.3
  • 22
    • 0032187713 scopus 로고    scopus 로고
    • A zero-equation turbulence model for indoor airflow simulation
    • PII S0378778898000206
    • Chen Q., Xu W.: A zero-equation turbulence model for indoor air flow simulation: Energy Buildings 1998 ; 28: 137-144. (Pubitemid 128401662)
    • (1998) Energy and Buildings , vol.28 , Issue.2 , pp. 137-144
    • Chen, Q.1    Xu, W.2
  • 24


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.