메뉴 건너뛰기




Volumn , Issue , 2008, Pages 3871-3874

Front-end electronics for a 1mm 3 resolution avalanche photodiode-based PET system with analog signal multiplexing

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG SIGNALS; ATTENUATION ,; ATTENUATION METHOD; CHANNEL COUNT; COMPTON INTERACTION; DYNAMIC RANGE; ENERGY RESOLUTIONS; FIGURE OF MERIT; FRONT END ELECTRONIC; HIGH GAIN; IN-CHANNEL; INTERACTION ENERGIES; LOW-ENERGY INTERACTIONS; MULTIPLEXING SCHEMES; OUTPUT SIGNAL; PHOTO PEAKS; PHOTOELECTRIC ABSORPTION; PHOTON DETECTION EFFICIENCY; PHOTON INTERACTIONS; POSITION IDENTIFICATION; POSITION SENSITIVE AVALANCHE PHOTODIODES; SENSITIVITY PERFORMANCE; TIME RESOLUTION;

EID: 67649195127     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774127     Document Type: Conference Paper
Times cited : (8)

References (7)
  • 1
    • 33846643984 scopus 로고    scopus 로고
    • Study of the performance of a novel 1 mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation
    • DOI 10.1118/1.2409480
    • J. Zhang, P. D. Olcott, G. Chinn, A. M. K. Foudray, C.S. Levin, "Study of the Performance of a novel 1mm resolution dual-panel PET camera design dedicated to breast cancer imaging using Monte Carlo simulation," Medical Physics, vol.34, no. 2, pp.689-702, Feb 2007. (Pubitemid 46185149)
    • (2007) Medical Physics , vol.34 , Issue.2 , pp. 689-702
    • Zhang, J.1    Olcott, P.D.2    Chinn, G.3    Foudray, A.M.K.4    Levin, C.S.5
  • 2
    • 34250707850 scopus 로고    scopus 로고
    • Performance characterization of a novel thin position-sensitive avalanche photodiode for 1 mm resolution positron emission tomography
    • DOI 10.1109/TNS.2007.894128
    • J. Zhang; A. M. K. Foudray, P. D. Olcott, R. Farrell, K. Shah, C. S. Levin, "Performance Characterization of a Novel Thin PositionSensitive Avalanche Photodiode for 1 mm Resolution Positron Emission Tomography," IEEE Transactions on Nuclear Science , vo1.54, no.3, pp.415-421, June 2007. (Pubitemid 46956977)
    • (2007) IEEE Transactions on Nuclear Science , vol.54 , Issue.3 , pp. 415-421
    • Zhang, J.1    Foudray, A.M.K.2    Olcott, P.D.3    Farrell, R.4    Shah, K.5    Levin, C.S.6
  • 3
    • 67649140495 scopus 로고    scopus 로고
    • RENA-3 IC user specifications
    • NOVA R&D, Inc., Riverside, CA, June 7
    • "RENA-3 IC User Specifications," Rev. 1.1 b, NOVA R&D, Inc., Riverside, CA, June 7 2007.
    • (2007) Rev. 1.1b
  • 6
    • 67649148019 scopus 로고    scopus 로고
    • Effects of photon multiple interactions in a high resolution PET system that Uses 3-D positioning detectors
    • Y. Gu, C. Levin, "Effects of Photon Multiple Interactions in a High Resolution PET System That Uses 3-D Positioning Detectors," in IEEE Nuclear Science Symposium Conrference Record, 2008.
    • (2008) IEEE Nuclear Science Symposium Conference Record
    • Gu, Y.1    Levin, C.2
  • 7
    • 48149096565 scopus 로고    scopus 로고
    • Accurately positioning events in a highresolution PET system that uses 3D CZT detectors
    • G. Pratx, C. S. Levin, "Accurately positioning events in a highresolution PET system that uses 3D CZT detectors," in IEEE Nuclear Science Symposium Conference Record, 2007, vol.5, pp. 2660-2664.
    • (2007) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2660-2664
    • Pratx, G.1    Levin, C.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.