-
1
-
-
56749178486
-
Current trends in preclinical PET system design
-
C. S. Levin and H.Zaidi,"Current Trends in Preclinical PET System Design", PET Clinics, vol. 2, issue 2, pp. 125160,2007
-
(2007)
PET Clinics
, vol.2
, Issue.2
, pp. 125-160
-
-
Levin, C.S.1
Zaidi, H.2
-
2
-
-
41649088048
-
-
C. Catana, D. Procissi, Y. Wu, M. S. Judenhofer, J. Qi, B. Pichler, R. E. Jacobs and S. R. Cherry, "Simultaneous in vivo positron emission tomography and magnetic resonance imaging", PNAS, vol. 105, no. 10, pp. 3705-3710,2008
-
(2008)
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
, vol.105
, Issue.10
, pp. 3705-3710
-
-
Catana, C.1
Procissi, D.2
Wu, Y.3
Judenhofer, M.S.4
Qi, J.5
Pichler, B.6
Jacobs, R.E.7
Cherry, S.R.8
-
3
-
-
34548087667
-
PET/MR images acquired with a compact MR-compatible PET detector in a 7-T magnet
-
M. S. Judenhofer, C. Catana, B. K. Swann, S. B. Siegel, W.-I. Jung, R. E. Nutt, S. R. Cherry, C. D. Claussen and B Pichler, "PET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet". Radiology, vol 244, no 3, pp. 639-647,2007
-
Radiology
, vol.244
, Issue.3
, pp. 639-647
-
-
Judenhofer, M.S.1
Catana, C.2
Swann, B.K.3
Siegel, S.B.4
Jung, W.-I.5
Nutt, R.E.6
Cherry, S.R.7
Claussen, C.D.8
Pichler, B.9
-
5
-
-
33847711369
-
Performance evaluation of the microPET®-FocusF120
-
R. Laforest, D. Longford, S Siegel, D. F. Newport and J. Yap. "Performance Evaluation of the microPET® - FocusFI20", IEEE Trans Nucl Sci, vol 54, no 1, pp. 42-49, 2007
-
(2007)
IEEE Trans Nucl Sci
, vol.54
, Issue.1
, pp. 42-49
-
-
Laforest, R.1
Longford, D.2
Siegel, S.3
Newport, D.F.4
Yap, J.5
-
6
-
-
0029324694
-
A cryogen-free open superconducting magnet for interventional MRI applications
-
E. T. Laskaris, R. Ackermann, B. Doni, D. Gross, K. Herd, and C. Minas, "A Cryogen-Free Open Superconducting Magnet For Interventional MRI Applications", IEEE Trans. Appl. Supercond., vol.5, no. 2, pp. 163-168, 1995
-
(1995)
IEEE Trans. Appl. Supercond.
, vol.5
, Issue.2
, pp. 163-168
-
-
Laskaris, E.T.1
Ackermann, R.2
Doni, B.3
Gross, D.4
Herd, K.5
Minas, C.6
-
7
-
-
67649182526
-
Split cylindrical gradient coil for combined PET-MR system
-
Toronto, May
-
D. Green, S. Pittard, M. Poole, R. W. Bowtell, R. C. Hawkes, A. Lucas and T. A. Carpenter, "Split Cylindrical Gradient Coil for Combined PET-MR System", ISMRM 2008, Toronto, May 2008
-
(2008)
ISMRM 2008
-
-
Green, D.1
Pittard, S.2
Poole, M.3
Bowtell, R.W.4
Hawkes, R.C.5
Lucas, A.6
Carpenter, T.A.7
-
8
-
-
38649114714
-
Development of a combined microPET®-MR system
-
San Diego
-
A. Lucas, R. C. Hawkes, P. Guerra, R. E. Ansorge, R. E. Nutt, J. C. Clark, T. D. Fryer and T. A. Carpenter "Development of a combined microPET® -MR system", Proc. Conf. Rec. IEEE Nuclear Science Symp. And Medical Imaging Conf., San Diego, 2006, pp. 2345-2348.
-
(2006)
Proc. Conf. Rec. IEEE Nuclear Science Symp. And Medical Imaging Conf.
, pp. 2345-2348
-
-
Lucas, A.1
Hawkes, R.C.2
Guerra, P.3
Ansorge, R.E.4
Nutt, R.E.5
Clark, J.C.6
Fryer, T.D.7
Carpenter, T.A.8
-
9
-
-
0023640412
-
Treatment of axial data in three-dimensional PET
-
M. E. Daube-Witherspoon and G. Muehllehner, "Treatment of axial data in three-dimensional PET",J. Nucl. Med., vol. 28, no. 11, pp. 1717-1724, 1987. (Pubitemid 17160290)
-
(1987)
Journal of Nuclear Medicine
, vol.28
, Issue.11
, pp. 1717-1724
-
-
Daube-Witherspoon, M.E.1
Muehllehner, G.2
-
10
-
-
0031106959
-
Exact and approximate rebinning algorithms for 3-d pet data
-
PII S0278006297024889
-
M. Defrise, P. E. Kinahan, D. W. Townsend, M. Sibomana, and D. F.Newport, "Exact and approximate rebinning algorithms for 3-D PET data", IEEE Trans Med Imag., vol.16, pp. 145-158, 1997. (Pubitemid 127762926)
-
(1997)
IEEE Transactions on Medical Imaging
, vol.16
, Issue.2
, pp. 145-158
-
-
Defrise, M.1
Kinahan, P.E.2
Townsend, D.W.3
Michel, C.4
Sibomana, M.5
Newport, D.F.6
-
11
-
-
0024610693
-
Analytic 3D image reconstruction using all detected events
-
P.E. Kinahan and J.G. Rogers, "Analytic 3D image reconstruction using all detected events", IEEE Trans Nucl Sci., vol 36,pp.964-968, 1989
-
(1989)
IEEE Trans Nucl Sci.
, vol.36
, pp. 964-968
-
-
Kinahan, P.E.1
Rogers, J.G.2
-
12
-
-
12444305008
-
Performance evaluation of the microPET R4 PET scanner for rodents
-
C. Knoess, S. Siegel, A. Smith, D. Newport, N. Richerzhagen, A. Winkeler, A. Jacobs, R.N. Goble, R. Graf, K. Wienhard, W.O. Heiss, "Performance evaluation of the microPET R4 PET scanner for rodents", Eur. J. Nucl. Med, vol 30, no 5, pp. 737-747, 2003. (Pubitemid 36612958)
-
(2003)
European Journal of Nuclear Medicine and Molecular Imaging
, vol.30
, Issue.5
, pp. 737-747
-
-
Knoess, C.1
Siegel, S.2
Smith, A.3
Newport, D.4
Richerzhagen, N.5
Winkeler, A.6
Jacobs, A.7
Goble, R.N.8
Graf, R.9
Wienhard, K.10
Heiss, W.-D.11
|