메뉴 건너뛰기




Volumn , Issue , 2008, Pages 4260-4265

Pixel-based partial volume correction of small animal PET images using point spread function system characterization: Evaluation of effects on cardiac output, perfusion and metabolic rate using parametric images

Author keywords

Kinetic modeling; Parametric images; Partial Volume Correction; Small animal PET

Indexed keywords

ACCURATE ESTIMATION; ARTERIAL INPUT FUNCTION; BOOTSTRAP RESAMPLING; CARDIAC OUTPUT; COEFFICIENT OF VARIATION; COMPARTMENTAL MODEL; CORRECTED IMAGE; DYNAMIC IMAGES; KINETIC MODELING; METABOLIC RATES; MOUSE HEART; NOISE LEVELS; PARAMETRIC IMAGE; PARAMETRIC IMAGES; PARTIAL VOLUME CORRECTION; PARTIAL VOLUME EFFECT; PARTIAL VOLUMES; PERCENTAGE ERROR; PHYSIOLOGIC PARAMETERS; PHYSIOLOGICAL PARAMETERS; PIXEL VALUES; POINT-SPREAD FUNCTION; POINT-SPREAD FUNCTIONS; POSITRON RANGE; QUANTITATIVE ANALYSIS; RADIOTRACER CONCENTRATION; RELATIVE ERRORS; SMALL ANIMAL PET; THEORETICAL VALUES; TIME-ACTIVITY CURVES;

EID: 67649188712     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774223     Document Type: Conference Paper
Times cited : (6)

References (13)
  • 2
    • 0024386205 scopus 로고
    • 15O and positron emission tomography: Assessment and error analysis of a mathematical approach
    • P. Herrero, J. Markham and SR. Bergmann, Quantitation of myocardial blood flow with H2150 and positron emission tomography: assessment and error analysis of a mathematical approach. J. Compo Ass. Tom. 1989 13:862-73 (Pubitemid 19245083)
    • (1989) Journal of Computer Assisted Tomography , vol.13 , Issue.5 , pp. 862-873
    • Herrero, P.1    Markham, J.2    Bergmann, S.R.3
  • 3
    • 0032969019 scopus 로고    scopus 로고
    • Application of mathematical methods in dynamic nuclear medicine studies
    • DOI 10.1088/0031-9155/44/4/028, PII S0031915599445087
    • RS. Lawson, Application of mathematical methods in dynamic nuclear medicine studies. Phys. Med. BioI. 199944:R57-98 (Pubitemid 29185374)
    • (1999) Physics in Medicine and Biology , vol.44 , Issue.4
    • Lawson, R.S.1
  • 5
  • 6
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumor imaging
    • DOI 10.2967/jnumed.106.035774
    • M. Soret , SL. Bacharach and Buvat, Partial-Volume effect in PET tumor imaging. J. Nucl. Med., 2007 48:932-45 (Pubitemid 46909922)
    • (2007) Journal of Nuclear Medicine , vol.48 , Issue.6 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 7
    • 2942654916 scopus 로고    scopus 로고
    • Development of a 4-digital mouse phantom for molecular imaging research
    • DOI 10.1016/j.mibio.2004.03.002, PII S1536163204002173
    • W.P. Segars, B.M.W. Tsui, E.C. Frey, G.A. Johnson and S.S. Berr, Development of a 4D digital mouse phantom for molecular imaging research. Molecular Imaging and Biology, 2004 6(3): 149-59 (Pubitemid 38771978)
    • (2004) Molecular Imaging and Biology , vol.6 , Issue.3 , pp. 149-159
    • Segars, W.P.1    Tsui, B.M.W.2    Frey, E.C.3    Johnson, G.A.4    Berr, S.S.5
  • 9
    • 0027572378 scopus 로고
    • Models for computer simulation studies of input functions for tracer kinetic modeling with positron emission tomography
    • D. Feng , SC. Huang and X. Wang, Models for computer simulations studies of input functions for tracer kinetic modeling with positron emission tomography. Int. Biomed. Comput., 1993 32:95-110 (Pubitemid 23090835)
    • (1993) International Journal of Bio-Medical Computing , vol.32 , Issue.2 , pp. 95-110
    • Feng, D.1    Huang, S.-C.2    Wang, X.3
  • 10
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • MI-l
    • LA. Shepp and Y. Vardi, Maximum Likelihood Reconstruction for Emission Tomography. IEEE Trans. Nucl. Sci., 1982 MI-l
    • (1982) IEEE Trans. Nucl. Sci.
    • Shepp, L.A.1    Vardi, Y.2
  • 13
    • 0030740610 scopus 로고    scopus 로고
    • Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals
    • DOI 10.1007/s002590050120
    • G. Brix, J. Doll, ME. Bellemann, H. Trojan, U. Haberkorn, Shmidlin and H. Ostertag, Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals. Eur 1. Nucl. Med., 1997 24:779-86 (Pubitemid 27356858)
    • (1997) European Journal of Nuclear Medicine , vol.24 , Issue.7 , pp. 779-786
    • Brix, G.1    Doll, J.2    Bellemann, M.E.3    Trojan, H.4    Haberkorn, U.5    Schmidlin, P.6    Ostertag, H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.