메뉴 건너뛰기




Volumn , Issue , 2008, Pages 4773-4779

Performance comparison of two commercial small animal PET scanners: ClearPETTM and rPET-1TM

Author keywords

[No Author keywords available]

Indexed keywords

AXIAL FIELD OF VIEWS; CLEARPET; MADRID , SPAIN; PERFORMANCE COMPARISON; PET SCANNER; RING DETECTOR; SCATTER FRACTIONS; SMALL ANIMAL; SMALL ANIMAL PET SCANNERS; SMALL VARIATIONS; SPATIAL RESOLUTION; THREE AXES; TRANSVERSE AXIS;

EID: 67649180442     PISSN: 10957863     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/NSSMIC.2008.4774310     Document Type: Conference Paper
Times cited : (4)

References (11)
  • 2
    • 39049175635 scopus 로고    scopus 로고
    • Positron emission tomography imaging as a key enabling technology in drug development
    • T. J. McCarthy, "Positron emission tomography imaging as a key enabling technology in drug development," Ernst Schering Res Found Workshop, vol.62, no. 3, pp. 29-39, 2007.
    • (2007) Ernst Schering Res Found Workshop , vol.62 , Issue.3 , pp. 29-39
    • McCarthy, T.J.1
  • 3
    • 67649179516 scopus 로고    scopus 로고
    • 0-75334 Straubenhardt. Registrar: HRB 501307 in Mannheim, Germany
    • Raytest Isotopenmessgeraete GmbH. BenzstraBe 4. 0-75334 Straubenhardt. Registrar: HRB 501307 in Mannheim, Germany. http://www.raytest.com
    • Raytest Isotopenmessgeraete GmbH. Benzstraβe 4.
  • 5
    • 67649156801 scopus 로고    scopus 로고
    • Development of an optimised LSOlLuYAP phoswich detector head for the ClearPET camera
    • Oct.
    • B. Mosset, O. Devroede, M. Krieguer, M. Rey et aI., "Development of an optimised LSOlLuYAP phoswich detector head for the ClearPET camera," IEEE NSS 005 Conf. Rec. vol.3, pp, 1641-1644, Oct. 2005.
    • (2005) IEEE NSS 2005 Conf. Rec. , vol.3 , pp. 1641-1644
    • Mosset, B.1    Devroede, O.2    Krieguer, M.3    Rey, M.4
  • 6
    • 33846572458 scopus 로고    scopus 로고
    • RPET detectors design and data processing
    • DOI 10.1109/NSSMIC.2005.1596934, 1596934, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • J. J Vaquero, E. Lage, Ricon, M. Abella, E. Vicente and M. Desco, "rPET detectors design and data processing," IEEE NSS 2005 Conf. Rec. vol.5, pp. 2885-2889, Oct. 2005. (Pubitemid 46172339)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2885-2889
    • Vaquero, J.J.1    Lage, E.2    Ricon, L.3    Abella, M.4    Vicente, E.5    Desco, M.6
  • 10
    • 0142063370 scopus 로고    scopus 로고
    • Design optimization of the PMT-clear PET prototypes based on simulation with GEANT3
    • Oct.
    • U. Heinrichs, U. Pietrzyk and K. Ziemons "Design Optimization of the PMT-ClearPET Prototypes Based on simulation With GEANT3," IEEE Trans. Nucl. Sci. ol. 50, no. 5, pp. 1428-1432, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1428-1432
    • Heinrichs, U.1    Pietrzyk, U.2    Ziemons, K.3
  • 11
    • 33846643671 scopus 로고    scopus 로고
    • Normalization factors for the ClearPET® Neuro
    • DOI 10.1109/NSSMIC.2005.1596878, 1596878, 2005 IEEE Nuclear Science Symposium Conference Record -Nuclear Science Symposium and Medical Imaging Conference
    • S. Weber, B. Gundlich and M. Khodaverdi, "Normalization factors for the ClearPET Neuro," IEEE NSS 2005 Conf. Rec. vol.5, pp. 2632-2635, Oct. 2005. (Pubitemid 46172283)
    • (2005) IEEE Nuclear Science Symposium Conference Record , vol.5 , pp. 2632-2635
    • Weber, S.1    Gundlich, B.2    Khodaverdi, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.