메뉴 건너뛰기




Volumn 31, Issue 6, 2009, Pages 688-694

Continuous infusion thermodilution for assessment of coronary flow: Theoretical background and in vitro validation

Author keywords

Coronary circulation; Coronary flow; Coronary physiology; In vitro model; Thermodilution

Indexed keywords

CORONARY CIRCULATION; CORONARY FLOW; CORONARY PHYSIOLOGY; IN VITRO MODEL; THERMODILUTION;

EID: 67549146747     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.medengphy.2009.01.006     Document Type: Article
Times cited : (41)

References (18)
  • 1
    • 0029841529 scopus 로고    scopus 로고
    • Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve
    • de Bruyne B., Bartunek J., Sys S.U., Pijls N.H., Heyndrickx G.R., and Wijns W. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility, reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation 94 8 (1996) 1842-1849
    • (1996) Circulation , vol.94 , Issue.8 , pp. 1842-1849
    • de Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Pijls, N.H.4    Heyndrickx, G.R.5    Wijns, W.6
  • 2
    • 4344657057 scopus 로고    scopus 로고
    • Optimum guidance of complex PCI by coronary pressure measurement
    • Pijls N.H. Optimum guidance of complex PCI by coronary pressure measurement. Heart 90 9 (2004) 1085-1093
    • (2004) Heart , vol.90 , Issue.9 , pp. 1085-1093
    • Pijls, N.H.1
  • 5
    • 0027270180 scopus 로고
    • Clinical applications of Doppler coronary flow reserve measurements
    • White C.W. Clinical applications of Doppler coronary flow reserve measurements. Am J Cardiol 71 14 (1993) 10D-16D
    • (1993) Am J Cardiol , vol.71 , Issue.14
    • White, C.W.1
  • 6
    • 77049181625 scopus 로고
    • On the theory of the indicator-dilution method for measurement of blood flow and volume
    • Meier P., and Zierler K.L. On the theory of the indicator-dilution method for measurement of blood flow and volume. J Appl Physiol 6 12 (1954) 731-744
    • (1954) J Appl Physiol , vol.6 , Issue.12 , pp. 731-744
    • Meier, P.1    Zierler, K.L.2
  • 7
    • 0032009942 scopus 로고    scopus 로고
    • Measurement of flow velocity in the coronary circulation: requirements and pitfalls
    • Buchi M., and Jenni R. Measurement of flow velocity in the coronary circulation: requirements and pitfalls. Semin Interv Cardiol 3 1 (1998) 45-50
    • (1998) Semin Interv Cardiol , vol.3 , Issue.1 , pp. 45-50
    • Buchi, M.1    Jenni, R.2
  • 8
    • 10744223355 scopus 로고    scopus 로고
    • Validation of coronary flow reserve measurements by thermodilution in clinical practice
    • Barbato E., Aarnoudse W., Aengevaeren W.R., Werner G., Klauss V., Bojara W., et al. Validation of coronary flow reserve measurements by thermodilution in clinical practice. Eur Heart J 25 3 (2004) 219-223
    • (2004) Eur Heart J , vol.25 , Issue.3 , pp. 219-223
    • Barbato, E.1    Aarnoudse, W.2    Aengevaeren, W.R.3    Werner, G.4    Klauss, V.5    Bojara, W.6
  • 9
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • Ganz W., Donoso R., Marcus H.S., Forrester J.S., and Swan H.J. A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 27 4 (1971) 392-396
    • (1971) Am J Cardiol , vol.27 , Issue.4 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3    Forrester, J.S.4    Swan, H.J.5
  • 10
    • 0035940393 scopus 로고    scopus 로고
    • Coronary thermodilution to assess flow reserve: experimental validation
    • de Bruyne B., Pijls N.H., Smith L., Wievegg M., and Heyndrickx G.R. Coronary thermodilution to assess flow reserve: experimental validation. Circulation 104 17 (2001) 2003-2006
    • (2001) Circulation , vol.104 , Issue.17 , pp. 2003-2006
    • de Bruyne, B.1    Pijls, N.H.2    Smith, L.3    Wievegg, M.4    Heyndrickx, G.R.5
  • 11
  • 12
    • 0015108523 scopus 로고
    • Measurement of coronary sinus blood flow by continuous thermodilution in man
    • Ganz W., Tamura K., Marcus H.S., Donoso R., Yoshida S., and Swan H.J. Measurement of coronary sinus blood flow by continuous thermodilution in man. Circulation 44 2 (1971) 181-195
    • (1971) Circulation , vol.44 , Issue.2 , pp. 181-195
    • Ganz, W.1    Tamura, K.2    Marcus, H.S.3    Donoso, R.4    Yoshida, S.5    Swan, H.J.6
  • 13
    • 0017891759 scopus 로고
    • Coronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow
    • Mathey D.G., Chatterjee K., Tyberg J.V., Lekven J., Brundage B., and Parmley W.W. Coronary sinus reflux. A source of error in the measurement of thermodilution coronary sinus flow. Circulation 57 4 (1978) 778-786
    • (1978) Circulation , vol.57 , Issue.4 , pp. 778-786
    • Mathey, D.G.1    Chatterjee, K.2    Tyberg, J.V.3    Lekven, J.4    Brundage, B.5    Parmley, W.W.6
  • 14
    • 85047679424 scopus 로고
    • A comparison of thermodilution coronary sinus blood flows and krypton myocardial blood flows in the intact dog
    • Weisse A.B., and Regan T.J. A comparison of thermodilution coronary sinus blood flows and krypton myocardial blood flows in the intact dog. Cardiovasc Res 8 4 (1974) 526-533
    • (1974) Cardiovasc Res , vol.8 , Issue.4 , pp. 526-533
    • Weisse, A.B.1    Regan, T.J.2
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland J.M., and Altman D.G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1 8476 (1986) 307-310
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 18
    • 0028791287 scopus 로고
    • Comparing methods of measurement: why plotting difference against standard method is misleading
    • Bland J.M., and Altman D.G. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet 346 (1995) 1085-1087
    • (1995) Lancet , vol.346 , pp. 1085-1087
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.