메뉴 건너뛰기




Volumn 6, Issue 7, 2009, Pages 972-977

Echocardiographic study of the optimal atrioventricular delay at rest and during exercise in recipients of cardiac resynchronization therapy systems

Author keywords

Atrioventricular delay; Cardiac resynchronization therapy; Exercise echocardiography; Rate responsive pacing; Velocity time integral; Ventricular filling time

Indexed keywords

AGED; ARTICLE; ATRIOVENTRICULAR CONDUCTION; CARDIAC RESYNCHRONIZATION THERAPY; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; ECHOCARDIOGRAPHY; EXERCISE; FEMALE; HEART LEFT VENTRICLE OUTFLOW TRACT; HEART RATE; HUMAN; MALE; PRIORITY JOURNAL; REST;

EID: 67549137285     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2009.03.023     Document Type: Article
Times cited : (26)

References (12)
  • 1
    • 16844364826 scopus 로고    scopus 로고
    • The effect of cardiac resynchronization on morbidity and mortality in heart failure
    • Cleland J.G., Daubert J.C., Erdmann E., et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med 352 (2005) 1539-1549
    • (2005) N Engl J Med , vol.352 , pp. 1539-1549
    • Cleland, J.G.1    Daubert, J.C.2    Erdmann, E.3
  • 2
    • 0035932533 scopus 로고    scopus 로고
    • Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay
    • Cazeau S., Leclercq C., Lavergne T., et al. Effects of multisite biventricular pacing in patients with heart failure and intraventricular conduction delay. N Engl J Med 344 (2001) 873-880
    • (2001) N Engl J Med , vol.344 , pp. 873-880
    • Cazeau, S.1    Leclercq, C.2    Lavergne, T.3
  • 3
    • 0037071808 scopus 로고    scopus 로고
    • Cardiac resynchronization in chronic heart failure
    • Abraham W.T., Fisher W.G., Smith A.L., et al. Cardiac resynchronization in chronic heart failure. N Engl J Med 346 (2002) 1845-1853
    • (2002) N Engl J Med , vol.346 , pp. 1845-1853
    • Abraham, W.T.1    Fisher, W.G.2    Smith, A.L.3
  • 4
    • 2442479695 scopus 로고    scopus 로고
    • Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure
    • Bristow M.R., Saxon L.A., Boehmer J., et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med 350 (2004) 2140-2150
    • (2004) N Engl J Med , vol.350 , pp. 2140-2150
    • Bristow, M.R.1    Saxon, L.A.2    Boehmer, J.3
  • 5
    • 7744241195 scopus 로고    scopus 로고
    • Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy
    • Sawhney N., Waggoner A., Garhwal S., et al. Randomized prospective trial of atrioventricular delay programming for cardiac resynchronization therapy. Heart Rhythm 1 (2004) 526-567
    • (2004) Heart Rhythm , vol.1 , pp. 526-567
    • Sawhney, N.1    Waggoner, A.2    Garhwal, S.3
  • 6
    • 31444450241 scopus 로고    scopus 로고
    • Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy
    • Kerlan J.E., Sawhney N.S., Waggoner A.D., et al. Prospective comparison of echocardiographic atrioventricular delay optimization methods for cardiac resynchronization therapy. Heart Rhythm 3 (2006) 148-154
    • (2006) Heart Rhythm , vol.3 , pp. 148-154
    • Kerlan, J.E.1    Sawhney, N.S.2    Waggoner, A.D.3
  • 7
    • 33646685037 scopus 로고    scopus 로고
    • Echocardiographic assessment during exercise of heart failure patients with cardiac resynchronization therapy
    • Bordachar P., Lafitte S., Reuter S., et al. Echocardiographic assessment during exercise of heart failure patients with cardiac resynchronization therapy. Am J Cardiol 97 (2006) 1622-1625
    • (2006) Am J Cardiol , vol.97 , pp. 1622-1625
    • Bordachar, P.1    Lafitte, S.2    Reuter, S.3
  • 8
    • 18044383570 scopus 로고    scopus 로고
    • Rate-dependent AV delay optimization in cardiac resynchronization therapy
    • Scharf C., Li P., Muntwyler J., Chugh A., et al. Rate-dependent AV delay optimization in cardiac resynchronization therapy. Pacing Clin Electrophysiol 28 (2005) 279-284
    • (2005) Pacing Clin Electrophysiol , vol.28 , pp. 279-284
    • Scharf, C.1    Li, P.2    Muntwyler, J.3    Chugh, A.4
  • 9
    • 40349098297 scopus 로고    scopus 로고
    • Should we use the rate-adaptive AV delay in cardiac resynchronization therapy-pacing?
    • Melzer C., Bondke H., Körber T., et al. Should we use the rate-adaptive AV delay in cardiac resynchronization therapy-pacing?. Europace 10 (2008) 53-58
    • (2008) Europace , vol.10 , pp. 53-58
    • Melzer, C.1    Bondke, H.2    Körber, T.3
  • 10
    • 39649112399 scopus 로고    scopus 로고
    • The atrioventricular delay of cardiac resynchronization can be optimized hemodynamically during exercise and predicted from resting measurements
    • Whinnett Z.I., Briscoe C., Davies J.E., et al. The atrioventricular delay of cardiac resynchronization can be optimized hemodynamically during exercise and predicted from resting measurements. Heart Rhythm 5 (2008) 378-386
    • (2008) Heart Rhythm , vol.5 , pp. 378-386
    • Whinnett, Z.I.1    Briscoe, C.2    Davies, J.E.3
  • 11
    • 45849110223 scopus 로고    scopus 로고
    • Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: early clinical results
    • Delnoy P.P., Marcelli E., Oudeluttikhuis H., et al. Validation of a peak endocardial acceleration-based algorithm to optimize cardiac resynchronization: early clinical results. Europace 10 (2008) 801-808
    • (2008) Europace , vol.10 , pp. 801-808
    • Delnoy, P.P.1    Marcelli, E.2    Oudeluttikhuis, H.3
  • 12
    • 33846342565 scopus 로고    scopus 로고
    • Acute evaluation of programmer-guided AV/PV and VV delay optimization comparing an IEGM method and echocardiogram for cardiac resynchronization therapy in heart failure patients and dual-chamber ICD implants
    • Baker II J.H., McKenzie III J., Beau S., et al. Acute evaluation of programmer-guided AV/PV and VV delay optimization comparing an IEGM method and echocardiogram for cardiac resynchronization therapy in heart failure patients and dual-chamber ICD implants. J Cardiovasc Electrophysiol 18 (2007) 185-191
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 185-191
    • Baker II, J.H.1    McKenzie III, J.2    Beau, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.