Volumn , Issue , 2008, Pages

Continuous recording of the oscillometric mean arterial pressure by the differential servo system with two photoplethysmographic sensors

Author keywords

[No Author keywords available]

Indexed keywords

ARTERIAL PRESSURES; CARDIAC CYCLES; CIRCULATORY DYNAMICS; DIASTOLIC PRESSURE; IS COSTS; MEAN ARTERIAL PRESSURE; PHOTOPLETHYSMOGRAPHIC; PHYSICAL EXERCISE; PRESSURE SIGNAL; SERVO SYSTEM;

EID: 67549136259     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BIBE.2008.4696827     Document Type: Conference Paper
Times cited : (7)

References (10)
  • 1
    • 0032102644 scopus 로고    scopus 로고
    • Fifteen years experience with finger arterial pressure monitoring: Assessment and technology
    • B. P. M. Imholz, W. Wieling, G. A. van Montfrans, and K. H. Wesseling, "Fifteen years experience with finger arterial pressure monitoring: assessment and technology," Cardiovasc. Res., vol. 38, pp. 605-616, 1998.
    • (1998) Cardiovasc. Res , vol.38 , pp. 605-616
    • Imholz, B.P.M.1    Wieling, W.2    van Montfrans, G.A.3    Wesseling, K.H.4
  • 2
    • 0031933563 scopus 로고    scopus 로고
    • Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?
    • G. J. Langewouters, J. J. Settels, R. Roelandt, and K. H. Wesseling, "Why use Finapres or Portapres rather than intra-arterial or intermittent non-invasive techniques of blood pressure measurement?" J. Med. Eng. Techn., vol. 22, pp. 37-43, 1998.
    • (1998) J. Med. Eng. Techn , vol.22 , pp. 37-43
    • Langewouters, G.J.1    Settels, J.J.2    Roelandt, R.3    Wesseling, K.H.4
  • 3
    • 0026637505 scopus 로고
    • The reliability of non-invasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease
    • W. J. W. Bos, B. P. M. Imholz, J. van Goudoever, K. H. Wesseling, and G. A. van Montfrans, "The reliability of non-invasive continuous finger blood pressure measurement in patients with both hypertension and vascular disease," J. Hypertens., vol. 5, pp. 529-535, 1992.
    • (1992) J. Hypertens , vol.5 , pp. 529-535
    • Bos, W.J.W.1    Imholz, B.P.M.2    van Goudoever, J.3    Wesseling, K.H.4    van Montfrans, G.A.5
  • 4
    • 0002220170 scopus 로고
    • Photoelectric measurement of blood pressure, volume and flow in the finger
    • Dresden
    • J. Penaz, "Photoelectric measurement of blood pressure, volume and flow in the finger," in Digest of the 10th Int. Conf. Med. Biol. Eng., Dresden, 1973, p. 104.
    • (1973) Digest of the 10th Int. Conf. Med. Biol. Eng , pp. 104
    • Penaz, J.1
  • 7
    • 0023155260 scopus 로고
    • Non- invasive continuous blood pressure measurement from the finger: Optimal measurement conditions and factors affecting reliability
    • T. Kurki, N. Smith, N. Head, H. Dec-Silver, and A. Quinn, "Non- invasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability," J. Clin. Monit., vol. 3, pp. 6-13, 1987.
    • (1987) J. Clin. Monit , vol.3 , pp. 6-13
    • Kurki, T.1    Smith, N.2    Head, N.3    Dec-Silver, H.4    Quinn, A.5
  • 8
    • 0027771526 scopus 로고
    • Continuous, non-invasive volume-clamp blood pressure: Determinants of performance
    • S. K. L. Lal, A. S. Mihailidou, M. Cejnar, R. J. Henderson, M. Jones, and S. N. Hunyor, "Continuous, non-invasive volume-clamp blood pressure: determinants of performance," J. Hypertens., vol. 11, pp. 1413-1422, 1993.
    • (1993) J. Hypertens , vol.11 , pp. 1413-1422
    • Lal, S.K.L.1    Mihailidou, A.S.2    Cejnar, M.3    Henderson, R.J.4    Jones, M.5    Hunyor, S.N.6
  • 9
    • 0033830776 scopus 로고    scopus 로고
    • Venous emptying mediates a transient vasodilation in the human forearm
    • M. E. Tschakovsky, and R. L. Hughson, "Venous emptying mediates a transient vasodilation in the human forearm," Am. J. Physiol. Heart Circ. Physiol., vol. 279(3), pp. H1007-H1014, 2000.
    • (2000) Am. J. Physiol. Heart Circ. Physiol , vol.279 , Issue.3
    • Tschakovsky, M.E.1    Hughson, R.L.2
  • 10
    • 85047676115 scopus 로고
    • Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure
    • B. P. M. Imholz, J. J. Settels, H. van den Meiracher, K. H. Wesseling, and W. Wieling, "Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure," Cardiovasc. Res., vol. 24, pp. 214-221, 1990.
    • (1990) Cardiovasc. Res , vol.24 , pp. 214-221
    • Imholz, B.P.M.1    Settels, J.J.2    van den Meiracher, H.3    Wesseling, K.H.4    Wieling, W.5