메뉴 건너뛰기




Volumn 6, Issue 7, 2009, Pages 978-983

Transiliac ICD implantation: Defibrillation vector flexibility produces consistent success

Author keywords

Complications; Defibrillation testing; Defibrillation vector; Implantable cardioverter defibrillator; Leads; Transiliac approach

Indexed keywords

ADULT; ARTICLE; AXILLA; CLINICAL ARTICLE; CONTROLLED STUDY; DEFIBRILLATION; DEFIBRILLATOR; DEVICE INFECTION; FEMALE; FOLLOW UP; HEART LEFT VENTRICLE; HUMAN; ILIAC VEIN; MALE; PACEMAKER FAILURE; PRIORITY JOURNAL; RISK ASSESSMENT;

EID: 67549114310     PISSN: 15475271     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.hrthm.2009.03.031     Document Type: Article
Times cited : (16)

References (19)
  • 1
    • 0024319869 scopus 로고
    • Iliac vein approach to permanent pacemaker implantation
    • Ellestad M.H., and French J. Iliac vein approach to permanent pacemaker implantation. Pacing Clin Electrophysiol 12 (1989) 1030-1033
    • (1989) Pacing Clin Electrophysiol , vol.12 , pp. 1030-1033
    • Ellestad, M.H.1    French, J.2
  • 2
    • 0024205002 scopus 로고
    • A model to evaluate alternative methods of defibrillation threshold determination
    • Church T., Martinson M., Kallok M., et al. A model to evaluate alternative methods of defibrillation threshold determination. Pacing Clin Electrophysiol 11 (1988) 2002-2007
    • (1988) Pacing Clin Electrophysiol , vol.11 , pp. 2002-2007
    • Church, T.1    Martinson, M.2    Kallok, M.3
  • 3
    • 0030851509 scopus 로고    scopus 로고
    • Derivation of a defibrillator implant criterion based on probability of successful defibrillation
    • Degroot P.J., Church T.R., Mehra R., et al. Derivation of a defibrillator implant criterion based on probability of successful defibrillation. Pacing Clin Electrophysiol 20 (1997) 1924-1935
    • (1997) Pacing Clin Electrophysiol , vol.20 , pp. 1924-1935
    • Degroot, P.J.1    Church, T.R.2    Mehra, R.3
  • 4
    • 0037251180 scopus 로고    scopus 로고
    • Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators
    • Gold M.R., Breiter D., Leman R., et al. Safety of a single successful conversion of ventricular fibrillation before the implantation of cardioverter defibrillators. Pacing Clin Electrophysiol 26 (2003) 483-486
    • (2003) Pacing Clin Electrophysiol , vol.26 , pp. 483-486
    • Gold, M.R.1    Breiter, D.2    Leman, R.3
  • 5
    • 0037197741 scopus 로고    scopus 로고
    • Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS)
    • Gold M.R., Higgins S., Klein R., et al. Efficacy and temporal stability of reduced safety margins for ventricular defibrillation: primary results from the Low Energy Safety Study (LESS). Circulation 105 (2002) 2043-2048
    • (2002) Circulation , vol.105 , pp. 2043-2048
    • Gold, M.R.1    Higgins, S.2    Klein, R.3
  • 6
    • 13544250737 scopus 로고    scopus 로고
    • One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: an analysis from the Low Energy Safety Study (LESS)
    • Higgins S., Mann D., Calkins H., et al. One conversion of ventricular fibrillation is adequate for implantable cardioverter-defibrillator implant: an analysis from the Low Energy Safety Study (LESS). Heart Rhythm 2 (2005) 117-122
    • (2005) Heart Rhythm , vol.2 , pp. 117-122
    • Higgins, S.1    Mann, D.2    Calkins, H.3
  • 7
    • 0023360986 scopus 로고
    • The cardiac ventricular defibrillation threshold: inherent limitations in its application and interpretation
    • McDaniel W.C., and Schuder J.C. The cardiac ventricular defibrillation threshold: inherent limitations in its application and interpretation. Med Instrum 21 (1987) 170-176
    • (1987) Med Instrum , vol.21 , pp. 170-176
    • McDaniel, W.C.1    Schuder, J.C.2
  • 8
    • 0032407307 scopus 로고    scopus 로고
    • Combined use of a true-bipolar sensing implantable cardioverter defibrillator in a patient having a prior implantable spinal cord stimulator for intractable pain
    • Monahan K., Casavant D., Rasmussen C., et al. Combined use of a true-bipolar sensing implantable cardioverter defibrillator in a patient having a prior implantable spinal cord stimulator for intractable pain. Pacing Clin Electrophysiol 21 (1998) 2669-2672
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2669-2672
    • Monahan, K.1    Casavant, D.2    Rasmussen, C.3
  • 9
    • 0023127807 scopus 로고
    • Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate
    • Rattes M.F., Jones D.L., Sharma A.D., et al. Defibrillation threshold: a simple and quantitative estimate of the ability to defibrillate. Pacing Clin Electrophysiol 10 (1987) 70-77
    • (1987) Pacing Clin Electrophysiol , vol.10 , pp. 70-77
    • Rattes, M.F.1    Jones, D.L.2    Sharma, A.D.3
  • 10
    • 1342343905 scopus 로고    scopus 로고
    • Comparison of step-down and binary search algorithms for determination of defibrillation threshold in humans
    • Shorofsky S.R., Peters R.W., Rashba E.J., et al. Comparison of step-down and binary search algorithms for determination of defibrillation threshold in humans. Pacing Clin Electrophysiol 27 (2004) 218-220
    • (2004) Pacing Clin Electrophysiol , vol.27 , pp. 218-220
    • Shorofsky, S.R.1    Peters, R.W.2    Rashba, E.J.3
  • 11
    • 0026877545 scopus 로고
    • Defibrillation threshold: clinical utility and therapeutic implications
    • Singer I., and Lang D. Defibrillation threshold: clinical utility and therapeutic implications. Pacing Clin Electrophysiol 15 (1992) 932-949
    • (1992) Pacing Clin Electrophysiol , vol.15 , pp. 932-949
    • Singer, I.1    Lang, D.2
  • 12
    • 0033567055 scopus 로고    scopus 로고
    • Transiliac permanent pacemaker implantation after extraction of infected pectoral pacemaker systems
    • A479-410
    • Erdogan O., Augostini R., Saliba W., et al. Transiliac permanent pacemaker implantation after extraction of infected pectoral pacemaker systems. Am J Cardiol 84 (1999) 474-475 A479-410
    • (1999) Am J Cardiol , vol.84 , pp. 474-475
    • Erdogan, O.1    Augostini, R.2    Saliba, W.3
  • 13
    • 33645875869 scopus 로고    scopus 로고
    • How to manage the patient with a high defibrillation threshold
    • Mainigi S.K., and Callans D.J. How to manage the patient with a high defibrillation threshold. Heart Rhythm 3 (2006) 492-495
    • (2006) Heart Rhythm , vol.3 , pp. 492-495
    • Mainigi, S.K.1    Callans, D.J.2
  • 14
    • 20244387585 scopus 로고    scopus 로고
    • Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?
    • Russo A.M., Sauer W., Gerstenfeld E.P., et al. Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?. Heart Rhythm 2 (2005) 456-461
    • (2005) Heart Rhythm , vol.2 , pp. 456-461
    • Russo, A.M.1    Sauer, W.2    Gerstenfeld, E.P.3
  • 15
    • 17144451468 scopus 로고    scopus 로고
    • Effect of a single element subcutaneous array electrode added to a transvenous electrode configuration on the defibrillation field and the defibrillation threshold
    • Kuhlkamp V., Dornberger V., Khalighi K., et al. Effect of a single element subcutaneous array electrode added to a transvenous electrode configuration on the defibrillation field and the defibrillation threshold. Pacing Clin Electrophysiol 21 (1998) 2596-2605
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 2596-2605
    • Kuhlkamp, V.1    Dornberger, V.2    Khalighi, K.3
  • 16
    • 0031691493 scopus 로고    scopus 로고
    • Worldwide clinical experience with a down-sized active can implantable cardioverter defibrillator in 162 consecutive patients. Worldwide 7221 ICD Investigators
    • Sticherling C., Klingenheben T., Cameron D., et al. Worldwide clinical experience with a down-sized active can implantable cardioverter defibrillator in 162 consecutive patients. Worldwide 7221 ICD Investigators. Pacing Clin Electrophysiol 21 (1998) 1778-1783
    • (1998) Pacing Clin Electrophysiol , vol.21 , pp. 1778-1783
    • Sticherling, C.1    Klingenheben, T.2    Cameron, D.3
  • 17
    • 7544220287 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results
    • Wathen M.S., DeGroot P.J., Sweeney M.O., et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation 110 (2004) 2591-2596
    • (2004) Circulation , vol.110 , pp. 2591-2596
    • Wathen, M.S.1    DeGroot, P.J.2    Sweeney, M.O.3
  • 18
    • 15644375417 scopus 로고    scopus 로고
    • Effect of ventricular shock strength on cardiac hemodynamics
    • Tokano T., Bach D., Chang J., et al. Effect of ventricular shock strength on cardiac hemodynamics. J Cardiovasc Electrophysiol 9 (1998) 791-797
    • (1998) J Cardiovasc Electrophysiol , vol.9 , pp. 791-797
    • Tokano, T.1    Bach, D.2    Chang, J.3
  • 19
    • 0027418671 scopus 로고
    • Does ventricular fibrillation cause myocardial stunning during defibrillator implantation?
    • Spotnitz H.M. Does ventricular fibrillation cause myocardial stunning during defibrillator implantation?. J Card Surg 8 Suppl 2 (1993) 249-256
    • (1993) J Card Surg , vol.8 , Issue.SUPPL. 2 , pp. 249-256
    • Spotnitz, H.M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.