-
1
-
-
7544222929
-
Time-Domain Combination of MR Spectroscopy Data Acquired Using Phased-Array Coils
-
M. A. Brown. "Time-Domain Combination of MR Spectroscopy Data Acquired Using Phased-Array Coils", Magn Reson Med 52, pp. 1207-1213, (2004).
-
(2004)
Magn Reson Med
, vol.52
, pp. 1207-1213
-
-
Brown, M.A.1
-
3
-
-
67549118717
-
A Novel Approach to Signal-to-Noise Ratio Improvement of Magnetic Resonance Phased Array Spectroscopy Signals
-
accepted - to appear
-
N. Martini, M. F. Santarelli, M. Milanesi, G. Giovannetti, V. Positano, N. Vanello, L. Landini. "A Novel Approach To Signal-To-Noise Ratio Improvement of Magnetic Resonance Phased Array Spectroscopy Signals", 19th international EURASIP conference BIOSIGNAL 2008 (accepted - to appear).
-
(2008)
19th International EURASIP Conference BIOSIGNAL
-
-
Martini, N.1
Santarelli, M.F.2
Milanesi, M.3
Giovannetti, G.4
Positano, V.5
Vanello, N.6
Landini, L.7
-
4
-
-
34548385838
-
Cardiac steatosis in diabetes mellitus: A 1H-magnetic resonance spectroscopy study
-
J. M. McGavock, I. Lingvay, I Zib, T. Tillery, N. Salas, R. Unger et al. "Cardiac steatosis in diabetes mellitus: a 1H-magnetic resonance spectroscopy study". Circulation, 116, pp. 1170-1175, (2007).
-
(2007)
Circulation
, vol.116
, pp. 1170-1175
-
-
McGavock, J.M.1
Lingvay, I.2
Zib, I.3
Tillery, T.4
Salas, N.5
Unger, R.6
-
5
-
-
34548677080
-
1H MR Spectroscopy with Respiratory Navigator Gating in Volunteers
-
1H MR Spectroscopy with Respiratory Navigator Gating in Volunteers", Radiology 245, pp. 251-257, (2007).
-
(2007)
Radiology
, vol.245
, pp. 251-257
-
-
Van Der Meer, R.W.1
Doornbos, J.2
Kozerke, S.3
Schär, M.4
Bax, J.J.5
Hammer, S.6
Smit, J.W.A.7
Romijn, J.A.8
Diamant, M.9
Rijzewijk, L.J.10
De Roos, A.11
Lamb, H.J.12
-
6
-
-
0242712993
-
Proton Magnetic Resonance Spectroscopy Can Detect Creatine Depletion Associated with the Progression of Heart Failure in Cardiomyopathy
-
I. Nakae, K. Mitsunami, T. Omura, T Yabe, T. Tsutamoto, S. Matsuo, M. Takahashi, S. Morikawa, T. Inubushi, Y. Nakamura, M. Kinoshita, M. Horie. "Proton Magnetic Resonance Spectroscopy Can Detect Creatine Depletion Associated With the Progression of Heart Failure in Cardiomyopathy" Journal of the American College of Cardiology. 42(9) pp.1587-1593 (2003)
-
(2003)
Journal of the American College of Cardiology
, vol.42
, Issue.9
, pp. 1587-1593
-
-
Nakae, I.1
Mitsunami, K.2
Omura, T.3
Yabe, T.4
Tsutamoto, T.5
Matsuo, S.6
Takahashi, M.7
Morikawa, S.8
Inubushi, T.9
Nakamura, Y.10
Kinoshita, M.11
Horie, M.12
-
7
-
-
0037148046
-
An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes
-
T. Prock, D. J. Collins, A. S. K. Dzik-Jurasz, M. O. Leach. "An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes", Phys Med Biol 47(2), pp. N39-N46 (2002).
-
(2002)
Phys Med Biol
, vol.47
, Issue.2
-
-
Prock, T.1
Collins, D.J.2
Dzik-Jurasz, A.S.K.3
Leach, M.O.4
-
8
-
-
27144543513
-
Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: Reproducibility and sensitivity of the method
-
J. S. Reingold, J. M, McGavock, S Kaka, T Tillery, R. G. Victor, and L. S. Szczepaniak. "Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method", Am J Physiol Endocrinol Metab 289, pp. E935-E939, (2005).
-
(2005)
Am J Physiol Endocrinol Metab
, vol.289
-
-
Reingold, J.S.1
McGavock, J.M.2
Kaka, M.S.3
Tillery, T.4
Victor, R.G.5
Szczepaniak, L.S.6
-
9
-
-
0025226022
-
The NMR phased array
-
P. B. Roemer; W. A. Edelstein, C. E. Hayes, S. P. Souza, O. M. Mueller. "The NMR phased array", Magn Reson Med 16(2), pp. 192-225.
-
Magn Reson Med
, vol.16
, Issue.2
, pp. 192-225
-
-
Roemer, P.B.1
Edelstein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
10
-
-
67549084653
-
1H MR data quantitation: Reproducibility evaluation by simulation
-
EMBEC Prague
-
M. F. Santarelli, L. Landini, V. Positano, D. Montanaro, N. Vanello, A. Benassi, "1H MR data quantitation: reproducibility evaluation by simulation". EMBEC 2005, Prague. Proceedings of IFMBE 2005;11:no 1735.
-
(2005)
Proceedings of IFMBE 2005
, vol.11
, Issue.1735
-
-
Santarelli, M.F.1
Landini, L.2
Positano, V.3
Montanaro, D.4
Vanello, N.5
Benassi, A.6
-
11
-
-
0034963583
-
MR spectroscopy quantitation: A review of timedomain methods
-
L. Vanhamme, T. Sundin, P. Van Hecke, S. Van Huffel, "MR spectroscopy quantitation: a review of timedomain methods". NMR Biomed, 14, pp. 233-246, (2007).
-
(2007)
NMR Biomed
, vol.14
, pp. 233-246
-
-
Vanhamme, L.1
Sundin, T.2
Van Hecke, P.3
Van Huffel, S.4
-
12
-
-
0031425055
-
Theory and application of array coils in MR spectroscopy
-
S. M. Wright, L.L. Wald. "Theory and application of array coils in MR spectroscopy". NMR Biomed, 10(8), pp. 394-410, (1997).
-
(1997)
NMR Biomed
, vol.10
, Issue.8
, pp. 394-410
-
-
Wright, S.M.1
Wald, L.L.2
|