메뉴 건너뛰기




Volumn , Issue 540 CP, 2008, Pages

Signal-to-noise ratio improvement of cardiac magnetic resonance spectroscopy signals acquired by phased array coils: A simulation based approach

Author keywords

Magnetic resonance spectroscopy; PCA whitening; Phased array coils; SNR improvement

Indexed keywords

ACQUISITION CHANNELS; ACQUISITION STRATEGIES; BIOCHEMICAL INFORMATION; CORRELATED NOISE; IN-VIVO; LOW SNR; METABOLITE CONCENTRATIONS; MR SIGNALS; NONINVASIVE TECHNIQUE; NOVEL METHODS; PCA WHITENING; PERFORMANCE EVALUATION; PHASED ARRAY COILS; RECEIVING COIL; SIMULATION-BASED; SNR IMPROVEMENT;

EID: 67549084758     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/cp:20080445     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 1
    • 7544222929 scopus 로고    scopus 로고
    • Time-Domain Combination of MR Spectroscopy Data Acquired Using Phased-Array Coils
    • M. A. Brown. "Time-Domain Combination of MR Spectroscopy Data Acquired Using Phased-Array Coils", Magn Reson Med 52, pp. 1207-1213, (2004).
    • (2004) Magn Reson Med , vol.52 , pp. 1207-1213
    • Brown, M.A.1
  • 4
    • 34548385838 scopus 로고    scopus 로고
    • Cardiac steatosis in diabetes mellitus: A 1H-magnetic resonance spectroscopy study
    • J. M. McGavock, I. Lingvay, I Zib, T. Tillery, N. Salas, R. Unger et al. "Cardiac steatosis in diabetes mellitus: a 1H-magnetic resonance spectroscopy study". Circulation, 116, pp. 1170-1175, (2007).
    • (2007) Circulation , vol.116 , pp. 1170-1175
    • McGavock, J.M.1    Lingvay, I.2    Zib, I.3    Tillery, T.4    Salas, N.5    Unger, R.6
  • 7
    • 0037148046 scopus 로고    scopus 로고
    • An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes
    • T. Prock, D. J. Collins, A. S. K. Dzik-Jurasz, M. O. Leach. "An algorithm for the optimum combination of data from arbitrary magnetic resonance phased array probes", Phys Med Biol 47(2), pp. N39-N46 (2002).
    • (2002) Phys Med Biol , vol.47 , Issue.2
    • Prock, T.1    Collins, D.J.2    Dzik-Jurasz, A.S.K.3    Leach, M.O.4
  • 8
    • 27144543513 scopus 로고    scopus 로고
    • Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: Reproducibility and sensitivity of the method
    • J. S. Reingold, J. M, McGavock, S Kaka, T Tillery, R. G. Victor, and L. S. Szczepaniak. "Determination of triglyceride in the human myocardium by magnetic resonance spectroscopy: reproducibility and sensitivity of the method", Am J Physiol Endocrinol Metab 289, pp. E935-E939, (2005).
    • (2005) Am J Physiol Endocrinol Metab , vol.289
    • Reingold, J.S.1    McGavock, J.M.2    Kaka, M.S.3    Tillery, T.4    Victor, R.G.5    Szczepaniak, L.S.6
  • 11
    • 0034963583 scopus 로고    scopus 로고
    • MR spectroscopy quantitation: A review of timedomain methods
    • L. Vanhamme, T. Sundin, P. Van Hecke, S. Van Huffel, "MR spectroscopy quantitation: a review of timedomain methods". NMR Biomed, 14, pp. 233-246, (2007).
    • (2007) NMR Biomed , vol.14 , pp. 233-246
    • Vanhamme, L.1    Sundin, T.2    Van Hecke, P.3    Van Huffel, S.4
  • 12
    • 0031425055 scopus 로고    scopus 로고
    • Theory and application of array coils in MR spectroscopy
    • S. M. Wright, L.L. Wald. "Theory and application of array coils in MR spectroscopy". NMR Biomed, 10(8), pp. 394-410, (1997).
    • (1997) NMR Biomed , vol.10 , Issue.8 , pp. 394-410
    • Wright, S.M.1    Wald, L.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.