메뉴 건너뛰기




Volumn 31, Issue 7, 2009, Pages 505-510

Mechanical behavior of masonry assemblages manufactured with recycled-aggregate mortars

Author keywords

Bond strength; Elastic moduli; Recycled aggregate; Waste management

Indexed keywords

BOND STRENGTH; BUILDING LIFE CYCLE; FINE RECYCLED AGGREGATE; MASONRY STRUCTURES; MASONRY UNITS; MECHANICAL BEHAVIOR; PERFORMANCE EVALUATION; QUARTZ SAND; RECYCLED AGGREGATE; RECYCLED AGGREGATES; SEISMIC ACTIVITY;

EID: 67449152245     PISSN: 09589465     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cemconcomp.2009.05.003     Document Type: Article
Times cited : (77)

References (27)
  • 1
    • 2142734804 scopus 로고
    • Demolition and reuse of concrete and masonry
    • London, Great Britain: Chapman and Hall;
    • Kasai Y. Demolition and reuse of concrete and masonry. Reuse of demolition waste, vol. 2. London, Great Britain: Chapman and Hall; 1988.
    • (1988) Reuse of demolition waste , vol.2
    • Kasai, Y.1
  • 4
    • 33947580352 scopus 로고    scopus 로고
    • Mechanical behaviour of concrete made with fine recycled concrete aggregates
    • Evangelista L., and de Brito J. Mechanical behaviour of concrete made with fine recycled concrete aggregates. Cem Concr Compos 29 5 (2007) 397-401
    • (2007) Cem Concr Compos , vol.29 , Issue.5 , pp. 397-401
    • Evangelista, L.1    de Brito, J.2
  • 5
    • 0036887464 scopus 로고    scopus 로고
    • Use of rubble from building demolition in mortars
    • Corinaldesi V., Giuggiolini M., and Moriconi G. Use of rubble from building demolition in mortars. Waste Manage 22 8 (2002) 893-899
    • (2002) Waste Manage , vol.22 , Issue.8 , pp. 893-899
    • Corinaldesi, V.1    Giuggiolini, M.2    Moriconi, G.3
  • 6
    • 0347516502 scopus 로고    scopus 로고
    • Environmentally-friendly mortars: a way to improve bond between mortar and brick
    • Moriconi G., Corinaldesi V., and Antonucci R. Environmentally-friendly mortars: a way to improve bond between mortar and brick. Mater Struct 36 264 (2003) 702-708
    • (2003) Mater Struct , vol.36 , Issue.264 , pp. 702-708
    • Moriconi, G.1    Corinaldesi, V.2    Antonucci, R.3
  • 7
    • 54049093269 scopus 로고    scopus 로고
    • Behaviour of cementitious mortars containing different kinds of recycled aggregate
    • Corinaldesi V., and Moriconi G. Behaviour of cementitious mortars containing different kinds of recycled aggregate. Constr Build Mater 23 1 (2009) 289-294
    • (2009) Constr Build Mater , vol.23 , Issue.1 , pp. 289-294
    • Corinaldesi, V.1    Moriconi, G.2
  • 8
    • 0025463848 scopus 로고
    • IRA and the flexural bond strength of clay brick masonry
    • Philadelphia PA, USA, ASTM;, ASTM special technical publication no. 1063
    • McGinley WM. IRA and the flexural bond strength of clay brick masonry, in: Masonry components to assemblages. Philadelphia (PA, USA): ASTM; 1990. p. 217-34 [ASTM special technical publication no. 1063].
    • (1990) Masonry components to assemblages , pp. 217-234
    • McGinley, W.M.1
  • 9
    • 0030085674 scopus 로고    scopus 로고
    • Adhesion mechanisms in masonry
    • Robinson G.C. Adhesion mechanisms in masonry. Am Ceram Soc Bull 75 2 (1996) 81-86
    • (1996) Am Ceram Soc Bull , vol.75 , Issue.2 , pp. 81-86
    • Robinson, G.C.1
  • 10
    • 0031673742 scopus 로고    scopus 로고
    • Water extraction out of mortar during brick laying: a NMR study
    • Brocken H.J.P., Spiekman M.E., Pel L., Kopinga K., and Larbi J.A. Water extraction out of mortar during brick laying: a NMR study. Mater Struct 31 205 (1998) 49-57
    • (1998) Mater Struct , vol.31 , Issue.205 , pp. 49-57
    • Brocken, H.J.P.1    Spiekman, M.E.2    Pel, L.3    Kopinga, K.4    Larbi, J.A.5
  • 11
    • 67449168882 scopus 로고    scopus 로고
    • EN 197-1. Cement - part 1: composition, specifications and conformity criteria for common cements; 2000.
    • EN 197-1. Cement - part 1: composition, specifications and conformity criteria for common cements; 2000.
  • 12
    • 67449144845 scopus 로고    scopus 로고
    • UNI EN 13139. Aggregates for mortars; 2003.
    • UNI EN 13139. Aggregates for mortars; 2003.
  • 13
    • 67449119926 scopus 로고    scopus 로고
    • UNI EN 1744-1. Tests for chemical properties of aggregates - chemical analysis; 1999.
    • UNI EN 1744-1. Tests for chemical properties of aggregates - chemical analysis; 1999.
  • 14
    • 67449143983 scopus 로고    scopus 로고
    • UNI 8520-22. Aggregati per confezione di calcestruzzi - Determinazione della potenziale reattività degli aggregati in presenza di alcali (Aggregates for concretes - determination of potential alkali reactivity); 2002.
    • UNI 8520-22. Aggregati per confezione di calcestruzzi - Determinazione della potenziale reattività degli aggregati in presenza di alcali (Aggregates for concretes - determination of potential alkali reactivity); 2002.
  • 15
    • 67449162309 scopus 로고    scopus 로고
    • Corinaldesi V, Moriconi G. Role of chemical and mineral admixtures on performance and economics of recycled aggregate concrete. In: Malhotra VM, editor. Fly ash, silica fume, slag and natural pozzolans in concrete. Proceedings of the seventh CANMET/ACI international conference, Chennai (Madras), India, 2001, 2. Farmington Hills (MI, USA): American Concrete Institute; 2001. p. 869-84 [SP 199-50].
    • Corinaldesi V, Moriconi G. Role of chemical and mineral admixtures on performance and economics of recycled aggregate concrete. In: Malhotra VM, editor. Fly ash, silica fume, slag and natural pozzolans in concrete. Proceedings of the seventh CANMET/ACI international conference, Chennai (Madras), India, 2001, vol. 2. Farmington Hills (MI, USA): American Concrete Institute; 2001. p. 869-84 [SP 199-50].
  • 16
    • 67449117098 scopus 로고    scopus 로고
    • Corinaldesi V, Tittarelli F, Coppola L, Moriconi G. Feasibility and performance of recycled aggregate in concrete containing fly ash for sustainable buildings. In: Malhotra VM, editor. Sustainable development of cement and concrete. Proceedings of the three-day CANMET/ACI international symposium, San Francisco, USA, 2001. Farmington Hills (MI, USA): American Concrete Institute; 2001. p. 161-80 [SP 202-11].
    • Corinaldesi V, Tittarelli F, Coppola L, Moriconi G. Feasibility and performance of recycled aggregate in concrete containing fly ash for sustainable buildings. In: Malhotra VM, editor. Sustainable development of cement and concrete. Proceedings of the three-day CANMET/ACI international symposium, San Francisco, USA, 2001. Farmington Hills (MI, USA): American Concrete Institute; 2001. p. 161-80 [SP 202-11].
  • 17
    • 67449132879 scopus 로고    scopus 로고
    • Corinaldesi V, Moriconi G. The use of recycled aggregates from building demolition in self-compacting concrete. In: Wallevik O, Nielsson I, editors. RILEM proceedings PRO 33, proceedings of the 3rd international RILEM symposium on self-compacting concrete, Reykjavik, Iceland, August 17-20, 2003. Bagneux, France; RILEM Publications S.A.R.L: 2003. p. 251-60.
    • Corinaldesi V, Moriconi G. The use of recycled aggregates from building demolition in self-compacting concrete. In: Wallevik O, Nielsson I, editors. RILEM proceedings PRO 33, proceedings of the 3rd international RILEM symposium on "self-compacting concrete", Reykjavik, Iceland, August 17-20, 2003. Bagneux, France; RILEM Publications S.A.R.L: 2003. p. 251-60.
  • 18
    • 41049096063 scopus 로고    scopus 로고
    • Tests for geometrical properties of aggregates - determination of particle size distribution - sieving method
    • EN 933-1
    • EN 933-1. Tests for geometrical properties of aggregates - determination of particle size distribution - sieving method; 1997.
    • (1997)
  • 19
    • 67349223891 scopus 로고    scopus 로고
    • Tests for mechanical and physical properties of aggregates - determination of particle density and water absorption
    • EN 1097-6
    • EN 1097-6. Tests for mechanical and physical properties of aggregates - determination of particle density and water absorption; 2000.
    • (2000)
  • 20
    • 67449150435 scopus 로고    scopus 로고
    • UNI EN 1015-3. Methods of test for mortar for masonry. Determination of consistence of fresh mortar (by flow table); 1999.
    • UNI EN 1015-3. Methods of test for mortar for masonry. Determination of consistence of fresh mortar (by flow table); 1999.
  • 21
    • 0033321477 scopus 로고    scopus 로고
    • The influence of water flow (reversal) on bond strength development in young masonry
    • Groot C., and Larbi J. The influence of water flow (reversal) on bond strength development in young masonry. Heron 44 2 (1999) 63-77
    • (1999) Heron , vol.44 , Issue.2 , pp. 63-77
    • Groot, C.1    Larbi, J.2
  • 22
    • 67449143975 scopus 로고    scopus 로고
    • Methods of test for mortar for masonry. Determination of flexural and compressive strength of hardened
    • EN 1015-11, mortar;
    • EN 1015-11. Methods of test for mortar for masonry. Determination of flexural and compressive strength of hardened mortar; 1999.
    • (1999)
  • 23
    • 67449114267 scopus 로고    scopus 로고
    • UNI EN 1052-3. Methods of test for masonry. Part 3: determination of initial shear strength; 2003.
    • UNI EN 1052-3. Methods of test for masonry. Part 3: determination of initial shear strength; 2003.
  • 24
    • 39449087340 scopus 로고    scopus 로고
    • The effect of aggregate-to-cement ratio and types of aggregates on the properties of pre-cast concrete blocks
    • Poon C.S., and Lam C.S. The effect of aggregate-to-cement ratio and types of aggregates on the properties of pre-cast concrete blocks. Cem Concr Compos 30 4 (2008) 283-289
    • (2008) Cem Concr Compos , vol.30 , Issue.4 , pp. 283-289
    • Poon, C.S.1    Lam, C.S.2
  • 25
    • 33845694784 scopus 로고    scopus 로고
    • Standard test method for compressive strength of masonry prisms
    • ASTM C 1314-03b
    • ASTM C 1314-03b. Standard test method for compressive strength of masonry prisms.
  • 26
    • 33947222698 scopus 로고    scopus 로고
    • Standard test methods for sampling and testing concrete masonry units and related units
    • ASTM C 140-05a
    • ASTM C 140-05a. Standard test methods for sampling and testing concrete masonry units and related units.
  • 27
    • 0006033299 scopus 로고    scopus 로고
    • Standard test method for diagonal tension (shear) in masonry assemblages
    • ASTM E 519-02
    • ASTM E 519-02. Standard test method for diagonal tension (shear) in masonry assemblages.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.