메뉴 건너뛰기




Volumn 88, Issue 6, 2009, Pages 964-966

Management of the difficult pediatric airway: Efficacy of airway exchange catheters with rigid bronchoscopy

Author keywords

[No Author keywords available]

Indexed keywords

ADENOTONSILLECTOMY; ANAMNESIS; ARTICLE; BRONCHOSCOPY; CASE REPORT; CATHETER; CHILD; CLINICAL FEATURE; HUMAN; INTENSIVE CARE; LARYNGOSCOPY; LUNG VENTILATION; MALE; OPERATING ROOM; PEDIATRIC ADVANCED LIFE SUPPORT; POLYSOMNOGRAPHY; PRESCHOOL CHILD;

EID: 67449150180     PISSN: 01455613     EISSN: None     Source Type: Journal    
DOI: 10.1177/014556130908800608     Document Type: Article
Times cited : (10)

References (15)
  • 1
    • 0030975058 scopus 로고    scopus 로고
    • A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway
    • Loudermilk EP, Hartmannsgruber M, Stoltzfus DP, Langevin PB. A prospective study of the safety of tracheal extubation using a pediatric airway exchange catheter for patients with a known difficult airway. Chest 1997; 111 (6): 1660-1665 (Pubitemid 27260099)
    • (1997) Chest , vol.111 , Issue.6 , pp. 1660-1665
    • Loudermilk, E.P.1    Hartmannsgruber, M.2    Stoltzfus, D.P.3    Langevin, P.B.4
  • 2
    • 0030871254 scopus 로고    scopus 로고
    • Prolonged use of a cook airway exchange catheter obviated the need for postoperative tracheostomy in an adult patient
    • DOI 10.1016/S0952-8180(97)00080-9, PII S0952818097000809
    • Hartmannsgruber MW, Loudermilk E, Stoltzfus D. Prolonged use of a Cook airway exchange catheter obviated the need for postoperative tracheostomy in an adult patient. J Clin Anesth 1997; 9 (6): 496-498 (Pubitemid 27355899)
    • (1997) Journal of Clinical Anesthesia , vol.9 , Issue.6 , pp. 496-498
    • Hartmannsgruber, M.W.B.1    Loudermilk, E.2    Stoltzfus, D.3
  • 3
    • 27144448939 scopus 로고    scopus 로고
    • The routine use of pediatric airway exchange catheter after extubation of adult patients who have undergone maxillofacial or major neck surgery: A clinical observational study
    • Dosemeci L, Yilmaz M, Yegin A, et al. The routine use of pediatric airway exchange catheter after extubation of adult patients who have undergone maxillofacial or major neck surgery: A clinical observational study. Crit Care 2004; 8 (6): R385-90.
    • (2004) Crit Care , vol.8 , Issue.6
    • Dosemeci, L.1    Yilmaz, M.2    Yegin, A.3
  • 4
    • 0035724767 scopus 로고    scopus 로고
    • The difficult paediatric airway: A new method of intubation intubation fibrescope
    • Thomas PB, Parry MG. The difficult paediatric airway: A new method of intubation intubation fibrescope. Paediatr Anaesth 2001; 11 (5): 618-621
    • (2001) Paediatr Anaesth , vol.11 , Issue.5 , pp. 618-621
    • Thomas, P.B.1    Parry, M.G.2
  • 5
    • 0032784095 scopus 로고    scopus 로고
    • Acromegaly and papillomatosis: Difficult intubation and use of the airway exchange catheter
    • DOI 10.1046/j.1365-2044.1999.00901.x
    • Hulme GJ, Blues CM. Acromegaly and papillomatosis: Difficult intubation and use of the airway exchange catheter. Anaesthesia 1999; 54 (8): 787-789 (Pubitemid 29389320)
    • (1999) Anaesthesia , vol.54 , Issue.8 , pp. 787-789
    • Hulme, G.J.1    Blues, C.M.2
  • 6
    • 22144445654 scopus 로고    scopus 로고
    • Utility of airway exchange catheters in pediatric patients with a known difficult airway
    • DOI 10.1097/01.PCC.0000163739.82584.C6
    • Wise-Faberowski L, Nargozian C. Utility of airway exchange catheters in pediatric patients with a known difficult airway. Pediatr Crit Care Med 2005; 6 (4): 454-456 (Pubitemid 40980827)
    • (2005) Pediatric Critical Care Medicine , vol.6 , Issue.4 , pp. 454-456
    • Wise-Faberowski, L.1    Nargozian, C.2
  • 7
    • 0036260467 scopus 로고    scopus 로고
    • Facilitation of passing the endotracheal tube over the flexible fiberoptic bronchoscope using a cook airway exchange catheter
    • DOI 10.1097/00000542-200206000-00036
    • Ayoub CM, Lteif AM, Rizk MS, et al. Facilitation of passing the endotracheal tube over the flexible fiberoptic bronchoscope using a Cook airway exchange catheter. Anesthesiology 2002; 96 (6): 1517-1518 (Pubitemid 34587225)
    • (2002) Anesthesiology , vol.96 , Issue.6 , pp. 1517-1518
    • Ayoub, C.M.1    Lteif, A.M.2    Rizk, M.S.3    Abu Jalad, N.M.4    Hadi, U.5    Baraka, A.S.6
  • 8
    • 0036908711 scopus 로고    scopus 로고
    • Special devices and techniques
    • DOI 10.1016/S0889-8537(02)00023-8, PII S0889853702000238
    • Hagberg CA. Special devices and techniques. Anesthesiol Clin North America 2002; 20 (4): 907-932 (Pubitemid 36008108)
    • (2002) Anesthesiology Clinics of North America , vol.20 , Issue.4 , pp. 907-932
    • Hagberg, C.A.1
  • 9
    • 4344708850 scopus 로고    scopus 로고
    • Management strategies for the difficult pediatric airway
    • Wheeler M. Management strategies for the difficult pediatric airway. Middle East J Anesthesiol 2004; 17 (5): 845-873 (Pubitemid 39158436)
    • (2004) Middle East Journal of Anesthesiology , vol.17 , Issue.5 , pp. 845-873
    • Wheeler, M.1
  • 10
  • 11
    • 0024815952 scopus 로고
    • Endobronchial rupture from endotracheal reintubation with an endotracheal tube guide
    • Seitz PA, Gravenstein N. Endobronchial rupture from endotracheal reintubation with an endotracheal tube guide. J Clin Anesth 1989; 1 (3): 214-217
    • (1989) J Clin Anesth , vol.1 , Issue.3 , pp. 214-217
    • Seitz, P.A.1    Gravenstein, N.2
  • 12
    • 0025744073 scopus 로고
    • Lung laceration after tracheal extubation over a plastic tube changer
    • de Lima LG, Bishop MJ. Lung laceration after tracheal extubation over a plastic tube changer. Anesth Analg 1991; 73 (3): 350-351
    • (1991) Anesth Analg , vol.73 , Issue.3 , pp. 350-351
    • De Lima, L.G.1    Bishop, M.J.2
  • 14
    • 0242332286 scopus 로고    scopus 로고
    • Fiberoptic intubation: Troubles with the "Tube"?
    • Wheeler M, Dsida RM. Fiberoptic intubation: Troubles with the "Tube"? Anesthesiology 2003; 99 (5): 1236-1237
    • (2003) Anesthesiology , vol.99 , Issue.5 , pp. 1236-1237
    • Wheeler, M.1    Dsida, R.M.2
  • 15
    • 1642541794 scopus 로고    scopus 로고
    • Rigid Bronchoscope-Assisted Endotracheal Intubation: Yet Another Use of the Gum Elastic Bougie
    • Nekhendzy V, Simmonds PK. Rigid bronchoscope-assisted endotracheal intubation: Yet another use of the gum elastic bougie. Anesth Analg 2004; 98 (2): 545-547, table of contents. (Pubitemid 38129413)
    • (2004) Anesthesia and Analgesia , vol.98 , Issue.2 , pp. 545-547
    • Nekhendzy, V.1    Simmonds, P.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.