메뉴 건너뛰기




Volumn 84, Issue 4, 2009, Pages 511-518

A novel microbial BOD biosensor developed by the immobilization of P. Syringae in micro-cellular polymers

Author keywords

Biochemical oxygen demand (BOD); Biosensor; Iimmobilized microorganisms; Micro cellular; Pseudomonas syringae

Indexed keywords

AMPEROMETRIC; AQUEOUS SAMPLES; BIOCHEMICAL OXYGEN DEMAND SENSOR; BIOCOMPOSITE; BOD SENSOR; CELLULAR POLYMER; ENVIRONMENTAL MONITORING; FLOW CELLS; FLOW-INJECTION SYSTEM; IIMMOBILIZED MICROORGANISMS; INDUSTRIAL WASTEWATERS; MICRO-CELLULAR; MICROBIAL ACTIVITIES; OPTIMAL RESPONSE; PSEUDOMONAS SYRINGAE; REPRODUCIBILITY; RESPONSE TIME; SENSOR RESPONSE; TEFLON MEMBRANES; WASTEWATER SAMPLES;

EID: 67449143721     PISSN: 02682575     EISSN: 10974660     Source Type: Journal    
DOI: 10.1002/jctb.2071     Document Type: Article
Times cited : (31)

References (31)
  • 1
    • 0003425384 scopus 로고
    • APHA, Section 5210, 18th edn. American Public Health Association, American Water Works Association, Water Environment Federation, Washington, DC, pp
    • APHA, Standard Methods for Examination of Water and Wastewater, Section 5210, 18th edn. American Public Health Association, American Water Works Association, Water Environment Federation, Washington, DC, pp. 5.1-5.6 (1992).
    • (1992) Standard Methods for Examination of Water and Wastewater
  • 2
    • 0000542685 scopus 로고
    • A rapid method for estimation of BOD by using immobilized microbial cells
    • Karube I, Matsunaga T and Suzuki S, A rapid method for estimation of BOD by using immobilized microbial cells. J Ferment Technol 55:243-251 (1977).
    • (1977) J Ferment Technol , vol.55 , pp. 243-251
    • Karube, I.1    Matsunaga, T.2    Suzuki, S.3
  • 4
    • 0021423502 scopus 로고
    • Rapid BOD measurement for municipal wastewater samples using a biofilm electrode
    • Strand SE and Carlson DA, Rapid BOD measurement for municipal wastewater samples using a biofilm electrode. J. Water Pollut. Cont. Fed 56:464-467 (1984).
    • (1984) J. Water Pollut. Cont. Fed , vol.56 , pp. 464-467
    • Strand, S.E.1    Carlson, D.A.2
  • 5
    • 0024374797 scopus 로고
    • Microbial BOD sensor utilizing thermophilic bacteria
    • Karube I, Yokoyama K, Sode K and Tamiya E, Microbial BOD sensor utilizing thermophilic bacteria. Anal Lett 22:791-801 (1989).
    • (1989) Anal Lett , vol.22 , pp. 791-801
    • Karube, I.1    Yokoyama, K.2    Sode, K.3    Tamiya, E.4
  • 6
    • 0026128647 scopus 로고
    • Study of BOD microbial sensors for waste water treatment control
    • Li YR and Chu J, Study of BOD microbial sensors for waste water treatment control. Appl Biochem Biotechnol 28:855-863 (1991).
    • (1991) Appl Biochem Biotechnol , vol.28 , pp. 855-863
    • Li, Y.R.1    Chu, J.2
  • 7
    • 0031130508 scopus 로고    scopus 로고
    • Dead Bacillus subtilis cells for sensing biochemical oxygen demand of waters and waste water
    • Tan TC and Qian ZR, Dead Bacillus subtilis cells for sensing biochemical oxygen demand of waters and waste water. Sens Acutators B40:65-70 (1997).
    • (1997) Sens Acutators , vol.B40 , pp. 65-70
    • Tan, T.C.1    Qian, Z.R.2
  • 8
    • 0032905929 scopus 로고    scopus 로고
    • Biosensor for the estimation of low biochemical oxygen demand
    • Gab-Joo C, Nomura Y and Karube I, Biosensor for the estimation of low biochemical oxygen demand. Analytica Chimica Acta 379:185-191 (1999).
    • (1999) Analytica Chimica Acta , vol.379 , pp. 185-191
    • Gab-Joo, C.1    Nomura, Y.2    Karube, I.3
  • 9
    • 0342980893 scopus 로고    scopus 로고
    • Immobilized activated sludge based biosensor for biochemical oxygen demand measurement
    • Liu J, Bjornsson L and Mattiasson B, Immobilized activated sludge based biosensor for biochemical oxygen demand measurement. Biosens Bioelectron 14:883-893 (2000).
    • (2000) Biosens Bioelectron , vol.14 , pp. 883-893
    • Liu, J.1    Bjornsson, L.2    Mattiasson, B.3
  • 11
    • 1842527824 scopus 로고    scopus 로고
    • Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process Part I. A novel design of BOD biosensor for easy renewal of bioreceptor
    • Liu J, Olsson G and Mattiasson B, Short-term BOD (BODst) as a parameter for on-line monitoring of biological treatment process Part I. A novel design of BOD biosensor for easy renewal of bioreceptor. Biosens Bioelectron 20:562-570 (2004).
    • (2004) Biosens Bioelectron , vol.20 , pp. 562-570
    • Liu, J.1    Olsson, G.2    Mattiasson, B.3
  • 13
    • 0029097452 scopus 로고
    • Bioreactors and biomembranes for biochemical oxygen demand estimation
    • Praet E, Reuter V, Gaillard T and Vasel JL, Bioreactors and biomembranes for biochemical oxygen demand estimation. Trends Anal Chem 14:371-379 (1995).
    • (1995) Trends Anal Chem , vol.14 , pp. 371-379
    • Praet, E.1    Reuter, V.2    Gaillard, T.3    Vasel, J.L.4
  • 14
    • 0029050984 scopus 로고
    • Rapid estimation of biochemical oxygen demand using a microbial multi-staged bioreactor
    • Sohn MJ, Lee JW, Chung C, Ihn GS and Hong D, Rapid estimation of biochemical oxygen demand using a microbial multi-staged bioreactor. Anal Chim Acta 313:221-228 (1995).
    • (1995) Anal Chim Acta , vol.313 , pp. 221-228
    • Sohn, M.J.1    Lee, J.W.2    Chung, C.3    Ihn, G.S.4    Hong, D.5
  • 16
    • 22044440606 scopus 로고    scopus 로고
    • On-line load monitoring of wastewaters with a respirographic microbial sensor
    • Vaiopoulou E, Melidis P, Kampragou E and Aivasidis A, On-line load monitoring of wastewaters with a respirographic microbial sensor. Biosensors Bioelectron 21:365-371 (2005).
    • (2005) Biosensors Bioelectron , vol.21 , pp. 365-371
    • Vaiopoulou, E.1    Melidis, P.2    Kampragou, E.3    Aivasidis, A.4
  • 17
    • 0017697028 scopus 로고
    • Biochemical fuel cell utilizing immobilized cells of Clostridium butyricum
    • Karube I, Matsunaga T, Tsuru S and Suzuki S, Biochemical fuel cell utilizing immobilized cells of Clostridium butyricum. Biosensors Bioelectron 19:1727-33 (1977).
    • (1977) Biosensors Bioelectron , vol.19 , pp. 1727-1733
    • Karube, I.1    Matsunaga, T.2    Tsuru, S.3    Suzuki, S.4
  • 18
    • 0346995405 scopus 로고    scopus 로고
    • Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor
    • Chang IS, Jang JK, Gil GC, Kim M, Kim HJ, Cho BW, et al, Continuous determination of biochemical oxygen demand using microbial fuel cell type biosensor. Biosensors Bioelectron 19:607-613 (2004).
    • (2004) Biosensors Bioelectron , vol.19 , pp. 607-613
    • Chang, I.S.1    Jang, J.K.2    Gil, G.C.3    Kim, M.4    Kim, H.J.5    Cho, B.W.6
  • 19
    • 12844252604 scopus 로고    scopus 로고
    • Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors
    • Chang IS, Moon H, Jang JK and Kim BH, Improvement of a microbial fuel cell performance as a BOD sensor using respiratory inhibitors. Biosensors Bioelectron 20:1856-1859 (2005).
    • (2005) Biosensors Bioelectron , vol.20 , pp. 1856-1859
    • Chang, I.S.1    Moon, H.2    Jang, J.K.3    Kim, B.H.4
  • 20
    • 0034531783 scopus 로고    scopus 로고
    • A mediator-type biosensor as a new approach to biochemical oxygen demand estimation
    • Yoshida N, Yano K, Morita T, McNiven SJ, Nakanura H and Karube I, A mediator-type biosensor as a new approach to biochemical oxygen demand estimation. Analyst 125:2280-2284 (2000).
    • (2000) Analyst , vol.125 , pp. 2280-2284
    • Yoshida, N.1    Yano, K.2    Morita, T.3    McNiven, S.J.4    Nakanura, H.5    Karube, I.6
  • 21
    • 0035850244 scopus 로고    scopus 로고
    • Improvement of a mediator-type biochemical oxygen demand sensor for on-site measurement
    • Yoshida N, Hoashi J, Morita T, McNiven SJ, Nakanura H and Karube I, Improvement of a mediator-type biochemical oxygen demand sensor for on-site measurement. J Biotechnol 88:269-275 (2001).
    • (2001) J Biotechnol , vol.88 , pp. 269-275
    • Yoshida, N.1    Hoashi, J.2    Morita, T.3    McNiven, S.J.4    Nakanura, H.5    Karube, I.6
  • 22
    • 0034302213 scopus 로고    scopus 로고
    • Optical fiber biosensor for the determination of low biochemical oxygen demand
    • Gab-Joo C, Nomura Y, Ikebukuro K and Karube I, Optical fiber biosensor for the determination of low biochemical oxygen demand. Biosensors Bioelectron 15:371-376 (2000).
    • (2000) Biosensors Bioelectron , vol.15 , pp. 371-376
    • Gab-Joo, C.1    Nomura, Y.2    Ikebukuro, K.3    Karube, I.4
  • 23
    • 0035639374 scopus 로고    scopus 로고
    • A compact optical system for multi-determination of biochemical oxygen demand using disposable strips
    • Yoshida N, McNiven SJ, Yoshida A, Morita T, Nakamura H and Karube I, A compact optical system for multi-determination of biochemical oxygen demand using disposable strips. Field Anal Chem Technol 5:222-227 (2001).
    • (2001) Field Anal Chem Technol , vol.5 , pp. 222-227
    • Yoshida, N.1    McNiven, S.J.2    Yoshida, A.3    Morita, T.4    Nakamura, H.5    Karube, I.6
  • 24
    • 23844472019 scopus 로고    scopus 로고
    • An optical biosensor for multisample determination of biochemical oxygen demand (BOD)
    • Kwok NY, Dong S, Lo W and Wong KY, An optical biosensor for multisample determination of biochemical oxygen demand (BOD). Sensors Actuators B110:289-298 (2005).
    • (2005) Sensors Actuators , vol.B110 , pp. 289-298
    • Kwok, N.Y.1    Dong, S.2    Lo, W.3    Wong, K.Y.4
  • 25
    • 32844464109 scopus 로고    scopus 로고
    • Novel BOD optical fiber biosensor based on co-immobilized microorganisms in ormosils matrix
    • Lin L, Xiao L, Huang S, Zhao L, Cui J, Wang X, et al, Novel BOD optical fiber biosensor based on co-immobilized microorganisms in ormosils matrix. Biosensors Bioelectron 21:1703 (2006).
    • (2006) Biosensors Bioelectron , vol.21 , pp. 1703
    • Lin, L.1    Xiao, L.2    Huang, S.3    Zhao, L.4    Cui, J.5    Wang, X.6
  • 26
    • 0037210423 scopus 로고    scopus 로고
    • Development and characterization of a novel immobilized microbial membrane for rapid determination of biochemical oxygen demand load in industrial waste-waters
    • Rastogi S, Kumar A, Mehra NK, Makhijani SD, Manoharan A, Gangal V, et al, Development and characterization of a novel immobilized microbial membrane for rapid determination of biochemical oxygen demand load in industrial waste-waters. Biosensors Bioelectron 18:23-29 (2003).
    • (2003) Biosensors Bioelectron , vol.18 , pp. 23-29
    • Rastogi, S.1    Kumar, A.2    Mehra, N.K.3    Makhijani, S.D.4    Manoharan, A.5    Gangal, V.6
  • 27
    • 0842286510 scopus 로고    scopus 로고
    • Phenol degradation in a fixed-bed bioreactor using micro-cellular polymer-immobilized Pseudomonas syringae
    • Erhan E, Yer E, Akay G, Keskinler B and Keskinler D, Phenol degradation in a fixed-bed bioreactor using micro-cellular polymer-immobilized Pseudomonas syringae. J Chem Technol Biotechnol 79:195-206 (2004).
    • (2004) J Chem Technol Biotechnol , vol.79 , pp. 195-206
    • Erhan, E.1    Yer, E.2    Akay, G.3    Keskinler, B.4    Keskinler, D.5
  • 28
    • 17644383311 scopus 로고    scopus 로고
    • Bioprocess intensification in flow-through monolithic microbioreactors with immobilized bacteria
    • Akay G, Erhan E and Keskinler B, Bioprocess intensification in flow-through monolithic microbioreactors with immobilized bacteria. Biosensors Bioelectron 90:180-190 (2005).
    • (2005) Biosensors Bioelectron , vol.90 , pp. 180-190
    • Akay, G.1    Erhan, E.2    Keskinler, B.3
  • 29
    • 47749154848 scopus 로고    scopus 로고
    • Biodegradation of high phenol containing synthetic wastewater by an aerobic fixed bed reactor
    • Bajaj M, Gallert C and Winter J, Biodegradation of high phenol containing synthetic wastewater by an aerobic fixed bed reactor. Bioresource Technol 99:8376-8381 (2008).
    • (2008) Bioresource Technol , vol.99 , pp. 8376-8381
    • Bajaj, M.1    Gallert, C.2    Winter, J.3
  • 30
    • 0032918081 scopus 로고    scopus 로고
    • Biodegradation of benzene, toluene, ethylbenzene, and o-xylene by a coculture of Pseudomonas putida and Pseudomonas fluorescens immobilized in a fibrous-bed bioreactor
    • Shim H and Yang ST, Biodegradation of benzene, toluene, ethylbenzene, and o-xylene by a coculture of Pseudomonas putida and Pseudomonas fluorescens immobilized in a fibrous-bed bioreactor. J Biotechnol 67:99-112 (1999).
    • (1999) J Biotechnol , vol.67 , pp. 99-112
    • Shim, H.1    Yang, S.T.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.