메뉴 건너뛰기




Volumn 30, Issue 6, 2009, Pages 1107-1115

Intra- and interobserver agreement and impact of arterial input selection in perfusion CT measurements performed in squamous cell carcinoma of the upper aerodigestive tract

Author keywords

[No Author keywords available]

Indexed keywords

IOMEPROL;

EID: 67449123587     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: 10.3174/ajnr.A1540     Document Type: Article
Times cited : (22)

References (26)
  • 1
    • 33846938307 scopus 로고    scopus 로고
    • Quantitative measurements of perfusion and permeability of oropharyngeal and oral cavity cancer, recurrent disease, and associated lymph nodes using first-pass contrast-enhanced computed tomography studies
    • DOI 10.1097/01.rli.0000252496.74242.0b, PII 0000442420070300000004
    • Bisdas S, Baghi M, Smolarz A, et al. Quantitative measurements of perfusion and permeability of oropharyngeal and oral cavity cancer, recurrent disease, and associated lymph nodes using first-pass contrast-enhanced computed tomography studies. Invest Radiol 2007;42:172-179 (Pubitemid 46232822)
    • (2007) Investigative Radiology , vol.42 , Issue.3 , pp. 172-179
    • Bisdas, S.1    Baghi, M.2    Smolarz, A.3    Pihno, N.C.4    Lehnert, T.5    Knecht, R.6    Mack, M.G.7    Vogl, T.J.8    Tuerkay, S.9    Koh, T.S.10
  • 2
    • 0041885111 scopus 로고    scopus 로고
    • Computed tomography perfusion of squamous cell carcinoma of the upper aerodigestive tract: Initial results
    • DOI 10.1097/00004728-200309000-00005
    • Gandhi D, Hoeffner EG, Carlos RC, et al. Computed tomography perfusion of squamous cell carcinoma of the upper aerodigestive tract: initial results. J Comput Assist Tomogr 2003;27:687-693 (Pubitemid 37087737)
    • (2003) Journal of Computer Assisted Tomography , vol.27 , Issue.5 , pp. 687-693
    • Gandhi, D.1    Hoeffner, E.G.2    Carlos, R.C.3    Case, I.4    Mukherji, S.K.5
  • 5
    • 33847138929 scopus 로고    scopus 로고
    • Can pretreatment CT perfusion predict response of advanced squamous cell carcinoma of the upper aerodigestive tract treated with induction chemotherapy?
    • Zima A, Carlos R, Gandhi D, et al. Can pretreatment CT perfusion predict response of advanced squamous cell carcinoma of the upper aerodigestive tract treated with induction chemotherapy? AJNR Am J Neuroradiol 2007;28:328-334 (Pubitemid 46281057)
    • (2007) American Journal of Neuroradiology , vol.28 , Issue.2 , pp. 328-334
    • Zima, A.1    Carlos, R.2    Gandhi, D.3    Case, I.4    Teknos, T.5    Mukherji, S.K.6
  • 6
    • 24644515509 scopus 로고    scopus 로고
    • Quantitative assessment of colorectal cancer perfusion using MDCT: Inter- And intraobserver agreement
    • Goh V, Halligan S, Hugill JA, et al. Quantitative assessment of colorectal cancer perfusion using MDCT: inter- and intraobserver agreement. AJR Am J Roentgenol 2005;185:225-231
    • (2005) AJR Am J Roentgenol , vol.185 , pp. 225-231
    • Goh, V.1    Halligan, S.2    Hugill, J.A.3
  • 7
    • 34447498780 scopus 로고    scopus 로고
    • CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: Initial experience
    • DOI 10.1148/radiol.2442061189
    • Bellomi M, Petralia G, Sonzogni A, et al. CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: initial experience. Radiology 2007;244:486-493 (Pubitemid 47080881)
    • (2007) Radiology , vol.244 , Issue.2 , pp. 486-493
    • Bellomi, M.1    Petralia, G.2    Sonzogni, A.3    Zampino, M.G.4    Rocca, A.5
  • 8
    • 33646136023 scopus 로고    scopus 로고
    • Lung cancer perfusion at multi-detector row CT: Reproducibility of whole tumor quantitative measurements
    • Ng QS, Goh V, Fichte H, et al. Lung cancer perfusion at multi-detector row CT: reproducibility of whole tumor quantitative measurements. Radiology 2006;239:547-553
    • (2006) Radiology , vol.239 , pp. 547-553
    • Ng, Q.S.1    Goh, V.2    Fichte, H.3
  • 10
    • 33748992003 scopus 로고    scopus 로고
    • Quantitative assessment of lung cancer perfusion using MDCT: Does measurement reproducibility improve with greater tumor volume coverage?
    • DOI 10.2214/AJR.05.0889
    • Ng QS, Goh V, Klotz E, et al. Quantitative assessment of lung cancer perfusion using MDCT: does measurement reproducibility improve with greater tumor volume coverage? AJR Am J Roentgenol 2006;187:1079-1084 (Pubitemid 44453967)
    • (2006) American Journal of Roentgenology , vol.187 , Issue.4 , pp. 1079-1084
    • Ng, Q.S.1    Goh, V.2    Klotz, E.3    Fichte, H.4    Saunders, M.I.5    Hoskin, P.J.6    Padhani, A.R.7
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • PII S0140673686908378
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-310 (Pubitemid 16134762)
    • (1986) Lancet , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • DOI 10.1191/096228099673819272
    • Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-160 (Pubitemid 29425900)
    • (1999) Statistical Methods in Medical Research , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 13844319702 scopus 로고    scopus 로고
    • Molecular imaging of antiangiogenic agents
    • DOI 10.1634/theoncologist.10-2-92
    • Rehman S, Jayson GC. Molecular imaging of antiangiogenic agents. Oncologist 2005;10:92-103 (Pubitemid 40261948)
    • (2005) Oncologist , vol.10 , Issue.2 , pp. 92-103
    • Rehman, S.1    Jayson, G.C.2
  • 18
    • 45949086825 scopus 로고    scopus 로고
    • Surrogate biomarkers in evaluating response to antiangiogenic agents: Focus on sunitinib
    • DePrimo SE, Bello C. Surrogate biomarkers in evaluating response to antiangiogenic agents: focus on sunitinib. Ann Oncol 2007;18(suppl 10):x11-19
    • (2007) Ann Oncol , vol.18 , Issue.SUPPL. 10
    • DePrimo, S.E.1    Bello, C.2
  • 19
    • 8844224812 scopus 로고    scopus 로고
    • Perfusion CT for the assessment of tumour vascularity: Which protocol?
    • DOI 10.1259/bjr/18486642, Angiogenesis Imaging
    • Miles KA. Perfusion CT for the assessment of tumour vascularity: which protocol? Br J Radiol 2003;76(spec no 1):S36-42 (Pubitemid 39530314)
    • (2003) British Journal of Radiology , vol.76 , Issue.SPEC. ISS. 1
    • Miles, K.A.1
  • 23
    • 13244277495 scopus 로고    scopus 로고
    • Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography: Effect of acquisition time and implications for protocols
    • DOI 10.1097/01.rct.0000152847.00257.d7
    • Goh V, Halligan S, Hugill JA, et al. Quantitative colorectal cancer perfusion measurement using dynamic contrast-enhanced multidetector-row computed tomography: effect of acquisition time and implications for protocols. J Comput Assist Tomogr 2005;29:59-63 (Pubitemid 40194439)
    • (2005) Journal of Computer Assisted Tomography , vol.29 , Issue.1 , pp. 59-63
    • Goh, V.1    Halligan, S.2    Hugill, J.-A.3    Gartner, L.4    Bartram, C.I.5
  • 24
    • 31144452463 scopus 로고    scopus 로고
    • A 45-second CT perfusion protocol for rectal cancers may not be adequate to infer vascular permeability-surface area products [3]
    • DOI 10.1148/radiol.2382050853
    • Kalra MK, Small WC, Torres WE. A 45-second CT perfusion protocol for rectal cancers may not be adequate to infer vascular permeability-surface area products. Radiology 2006;238:755-756 (Pubitemid 43134395)
    • (2006) Radiology , vol.238 , Issue.2 , pp. 755-756
    • Kalra, M.K.1    Small, W.C.2    Torres, W.E.3
  • 25
    • 33746173822 scopus 로고    scopus 로고
    • Quantitative colorectal cancer perfusion measurement by multidetector-row CT: Does greater tumour coverage improve measurement reproducibility?
    • DOI 10.1259/bjr/18842556
    • Goh V, Halligan S, Gartner L, et al. Quantitative colorectal cancer perfusion measurement by multidetector-row CT: does greater tumour coverage improve measurement reproducibility? Br J Radiol 2006;79:578-583 (Pubitemid 44083392)
    • (2006) British Journal of Radiology , vol.79 , Issue.943 , pp. 578-583
    • Goh, V.1    Halligan, S.2    Gartner, L.3    Bassett, P.4    Bartram, C.I.5
  • 26
    • 34249021801 scopus 로고    scopus 로고
    • Advanced hepatocellular carcinoma: CT perfusion of liver and tumor tissue - Initial experience
    • DOI 10.1148/radiol.2433052020
    • Sahani DV, Holalkere NS, Mueller PR, et al. Advanced hepatocellular carcinoma: CT perfusion of liver and tumor tissue - initial experience. Radiology 2007;243:736-743 (Pubitemid 46799427)
    • (2007) Radiology , vol.243 , Issue.3 , pp. 736-743
    • Sahani, D.V.1    Holalkere, N.-S.2    Mueller, P.R.3    Zhu, A.X.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.