메뉴 건너뛰기




Volumn , Issue 538 CP, 2008, Pages 16-21

Variable frequency adaptive selective compensation for active power filters

Author keywords

Active filters; Adaptive filters; Harmonic filtering; Selective current control

Indexed keywords

ACTIVE POWER FILTER; ADAPTIVE CURRENT CONTROLLER; AERONAUTIC APPLICATIONS; CURRENT CONTROL; CURRENT LOOP; FUNDAMENTAL FREQUENCIES; HARMONIC FILTERING; LOAD CURRENTS; NYQUIST FREQUENCY; NYQUIST LIMITS; PROCESS DELAY; RESONANT CONTROLLER; RESONANT FILTER; SELECTIVE COMPENSATION; SELECTIVE CURRENT CONTROL; VARIABLE FREQUENCIES;

EID: 67449102899     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1049/cp:20080475     Document Type: Conference Paper
Times cited : (15)

References (9)
  • 1
    • 0030289837 scopus 로고    scopus 로고
    • New trends in active filters for power conditioning
    • PII S0093999496070685
    • H. Akagi, "New Trends in Active Filters for Power Conditioning", IEEE Trans. on Ind. Applicat., vol.32, No. 6, Nov. 1996, pp.1312-1322. (Pubitemid 126777273)
    • (1996) IEEE Transactions on Industry Applications , vol.32 , Issue.6 , pp. 1312-1322
    • Akagi, H.1
  • 2
    • 0032166308 scopus 로고    scopus 로고
    • Parallel Active Filter Implementation and Design Issues for Utility Interface of Adjustable Speed Drive Systems
    • S. Bhattacharya, T. M. Frank, D. M. Divan, B. Banerjee, "Parallel Active Filter Implementation and Design Issues for Utility Interface of Adjustable Speed Drive Systems", IEEE Ind. Applicat. Mag., 1998, Vol. 4, Issue 5, pp. 47-63.
    • (1998) IEEE Ind. Applicat. Mag. , vol.4 , Issue.5 , pp. 47-63
    • Bhattacharya, S.1    Frank, T.M.2    Divan, D.M.3    Banerjee, B.4
  • 3
    • 28444466933 scopus 로고    scopus 로고
    • Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame
    • Nov.
    • R.I. Bojoi, G. Griva, V. Bostan, M. Guerrero, F. Farina, F. Profumo, "Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame", IEEE Trans. Power Electronics, vol.20, no. 6, Nov. 2005, pp. 1402-1412..
    • (2005) IEEE Trans. Power Electronics , vol.20 , Issue.6 , pp. 1402-1412
    • Bojoi, R.I.1    Griva, G.2    Bostan, V.3    Guerrero, M.4    Farina, F.5    Profumo, F.6
  • 4
    • 0032188197 scopus 로고    scopus 로고
    • Comparison of current control techniques for active filter applications
    • PII S0278004698070191
    • S. Buso, L. Malesani, P. Mattavelli, "Comparison of current control techniques for active filters applications", IEEE Trans. Industrial Electronics, vol.45, no. 5, Oct. 1998, pp. 722-729. (Pubitemid 128740292)
    • (1998) IEEE Transactions on Industrial Electronics , vol.45 , Issue.5 , pp. 722-729
    • Buso, S.1    Malesani, L.2    Mattavelli, P.3
  • 6
    • 34548746382 scopus 로고    scopus 로고
    • High performance current controller for selective harmonic compensation in active power filters
    • DOI 10.1109/TPEL.2007.904060
    • C. Lascu, L.Asiminoaei, I. Boldea, F. Blaabjerg, "High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters", EEE Transactions on Power Electronics, vol.22, no. 5, sep. 2007, pp: 1826-1835. (Pubitemid 47423057)
    • (2007) IEEE Transactions on Power Electronics , vol.22 , Issue.5 , pp. 1826-1835
    • Lascu, C.1    Asiminoaei, L.2    Boldea, I.3    Blaabjerg, F.4
  • 7
    • 0036506145 scopus 로고    scopus 로고
    • Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions
    • DOI 10.1109/28.993175, PII S009399940202666X
    • X. Yuan, W. Merk, H. Stemmler, J. Allmeling, "Stationary-frame generalized integrators for current control of active power filters with zero steady-state error for current harmonics of concern under unbalanced and distorted operating conditions", IEEE Tran. Ind. App., vol.38, no. 2, Mar./Apr. 2002, pp. 523-532. (Pubitemid 34491533)
    • (2002) IEEE Transactions on Industry Applications , vol.38 , Issue.2 , pp. 523-532
    • Yuan, X.1    Merk, W.2    Stemmler, H.3    Allmeling, J.4
  • 8
    • 0035087921 scopus 로고    scopus 로고
    • A closed-loop selective harmonic compensation for active filters
    • PII S009399940100891X
    • P. Mattavelli, "A closed-loop selective harmonic compensation for active filters", IEEE Trans. Industry Applications, vol.37, no. 1, Jan./Feb. 2001, pp. 81-89. (Pubitemid 33776039)
    • (2001) IEEE Transactions on Industry Applications , vol.37 , Issue.1 , pp. 81-89
    • Mattavelli, P.1
  • 9
    • 0038292050 scopus 로고    scopus 로고
    • Stationary Frame Current Regulation of PWM Inverters with Zero Steady-State Error
    • May
    • D. G. Holmes, D. N. Zmood, "Stationary Frame Current Regulation of PWM Inverters With Zero Steady-State Error", IEEE Trans. Power Electronics, vol.18, no. 3, May 2003, pp. 814-822.
    • (2003) IEEE Trans. Power Electronics , vol.18 , Issue.3 , pp. 814-822
    • Holmes, D.G.1    Zmood, D.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.