메뉴 건너뛰기




Volumn 32, Issue 5, 2009, Pages 1049-1057

Performance of mixture refrigerant R152a/R125/R32 in domestic air-conditioner

Author keywords

Air conditioner; Calculation; Comparison; Experiment; Flammability; Leak; R125; R152a; R32; Refrigerant; Ternary mixture; Thermodynamic property

Indexed keywords

AIR CONDITIONER; COMPARISON; LEAK; R125; R152A; R32; TERNARY MIXTURE;

EID: 67349274381     PISSN: 01407007     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijrefrig.2008.10.009     Document Type: Article
Times cited : (36)

References (15)
  • 3
    • 0030615391 scopus 로고    scopus 로고
    • Replacement of R22 in tube-and shell condenser: experiments and simulations
    • Gabrielii C., and Vamling L. Replacement of R22 in tube-and shell condenser: experiments and simulations. International Journal of Refrigeration 20 (1997) 165-178
    • (1997) International Journal of Refrigeration , vol.20 , pp. 165-178
    • Gabrielii, C.1    Vamling, L.2
  • 8
    • 0033523780 scopus 로고    scopus 로고
    • A Helmholtz energy equation of state for calculating the thermodynamic properties of fluid mixtures
    • Lemmon E.W., and Reiner R.T. A Helmholtz energy equation of state for calculating the thermodynamic properties of fluid mixtures. Fluid Phase Equilibria 165 (1999) 1-21
    • (1999) Fluid Phase Equilibria , vol.165 , pp. 1-21
    • Lemmon, E.W.1    Reiner, R.T.2
  • 9
    • 0033133328 scopus 로고    scopus 로고
    • A generalized model for the thermodynamic properties of mixtures
    • Lemmon E.W., and Jacobsen R.T. A generalized model for the thermodynamic properties of mixtures. International Journal of Thermophysics 20 3 (1999) 825-835
    • (1999) International Journal of Thermophysics , vol.20 , Issue.3 , pp. 825-835
    • Lemmon, E.W.1    Jacobsen, R.T.2
  • 11
    • 0029214346 scopus 로고
    • Equations of state for the thermodynamic properties of R32 (difluoromethane) and R125 (pentafluoroethane)
    • Outcalt S.L., and Mclinden M.O. Equations of state for the thermodynamic properties of R32 (difluoromethane) and R125 (pentafluoroethane). International Journal of Thermophysics 16 1 (1995) 79-89
    • (1995) International Journal of Thermophysics , vol.16 , Issue.1 , pp. 79-89
    • Outcalt, S.L.1    Mclinden, M.O.2
  • 12
    • 0030551735 scopus 로고    scopus 로고
    • A modified Benedict-Webb-Rubin equation of state for the thermodynamic properties of HFC152a (1,1-difluoroethane)
    • Outcalt S.L., and Mclinden M.O. A modified Benedict-Webb-Rubin equation of state for the thermodynamic properties of HFC152a (1,1-difluoroethane). Journal of Physical and Chemical Reference Data 25 2 (1996) 605-636
    • (1996) Journal of Physical and Chemical Reference Data , vol.25 , Issue.2 , pp. 605-636
    • Outcalt, S.L.1    Mclinden, M.O.2
  • 13
    • 67349219494 scopus 로고    scopus 로고
    • Progress in air enthalpy measure methods on test devices for air-conditioner
    • Shao S.Q., Shi W.X., and Yan Q.S. Progress in air enthalpy measure methods on test devices for air-conditioner. Experimental Technology and Management 19 (2002) 38-42
    • (2002) Experimental Technology and Management , vol.19 , pp. 38-42
    • Shao, S.Q.1    Shi, W.X.2    Yan, Q.S.3
  • 15
    • 67349098950 scopus 로고    scopus 로고
    • Yang, Z., Ma, Y.T., Lv, C.R., 2003. Efficiency environment friendly refrigerant. China, ZL 200310118983.0.
    • Yang, Z., Ma, Y.T., Lv, C.R., 2003. Efficiency environment friendly refrigerant. China, ZL 200310118983.0.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.