메뉴 건너뛰기




Volumn 129, Issue 6, 2009, Pages 741-746

Time-dependent release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick™ type artificial lumbar disc (Medtronic Sofamor Danek)

Author keywords

Chrome; Cobalt; Metal on metal; TDA; Weardebris

Indexed keywords

CHROMIUM; COBALT; HYDROXYAPATITE; METAL; TITANIUM;

EID: 67349251867     PISSN: 09368051     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00402-008-0677-8     Document Type: Article
Times cited : (24)

References (27)
  • 1
    • 0030907123 scopus 로고    scopus 로고
    • The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro
    • Allen MJ, Myer BJ, Millett PJ, Rushton N (1997) The effects of particulate cobalt, chromium and cobalt-chromium alloy on human osteoblast-like cells in vitro. J Bone Joint Surg Br 79(3):475-482
    • (1997) J Bone Joint Surg Br , vol.79 , Issue.3 , pp. 475-482
    • Allen, M.J.1    Myer, B.J.2    Millett, P.J.3    Rushton, N.4
  • 4
    • 0033626538 scopus 로고    scopus 로고
    • Serum cobalt and serum chromium level in 2 patients with chronic renal failure after total hip prosthesis implantation with metal-metal gliding contact
    • Article in German
    • Brodner W, Grohs JG, Bitzan P, Meisinger V, Kovarik J, Kotz R (2000) Serum cobalt and serum chromium level in 2 patients with chronic renal failure after total hip prosthesis implantation with metal-metal gliding contact. Z Orthop Ihre Grenzgeb 138(5):425-429 Article in German
    • (2000) Z Orthop Ihre Grenzgeb , vol.138 , Issue.5 , pp. 425-429
    • Brodner, W.1    Grohs, J.G.2    Bitzan, P.3    Meisinger, V.4    Kovarik, J.5    Kotz, R.6
  • 5
    • 67349106013 scopus 로고
    • Chrom (Chromium)
    • In: Zumkley H (ed) Georg Thieme Verlag Stuttgart, New York
    • Elwood JC (1993) Chrom (Chromium). In: Zumkley H (ed) Spurenelemente (Trace elements). Georg Thieme Verlag Stuttgart, New York
    • (1993) Spurenelemente (Trace Elements)
    • Elwood, J.C.1
  • 6
    • 67349199574 scopus 로고    scopus 로고
    • Diagnostik der inneren Exposition (Human-Biomonitoring)
    • In: Wichmann HE, Schlipköter HW, Füllgraf G (eds) 22nd edn. Ecomed Verlag, Landsberg, Chap
    • Ewers WM (2007) Diagnostik der inneren Exposition (Human-Biomonitoring) [Diagnosis of internal exposure (human biomonitoring)]. In: Wichmann HE, Schlipköter HW, Füllgraf G (eds) Handbuch der Umweltmedizin (Handbook of environmental medicine), 22nd edn. Ecomed Verlag, Landsberg, Chap. III-2.1
    • (2007) Handbuch Der Umweltmedizin (Handbook of Environmental Medicine)
    • Ewers, W.M.1
  • 7
    • 33947170536 scopus 로고    scopus 로고
    • Early removal of a Maverick disc prosthesis: Surgical findings and morphological changes
    • Francois J, Coessens R, Lauweryns P (2007) Early removal of a Maverick disc prosthesis: Surgical findings and morphological changes. Acta Orthop Belg 73(1):122-127
    • (2007) Acta Orthop Belg , vol.73 , Issue.1 , pp. 122-127
    • Francois, J.1    Coessens, R.2    Lauweryns, P.3
  • 8
    • 0033056715 scopus 로고    scopus 로고
    • Value and limits of determining serum cobalt levels in patients with metal on metal articulating prostheses
    • In French
    • Gleizes V, Poupon J, Lazennec JY, Chamberlin B, Saillant Q (1999) Value and limits of determining serum cobalt levels in patients with metal on metal articulating prostheses. Rev Chir Orthop Reparatrice Appar Mot 85:217-225 In French.
    • (1999) Rev Chir Orthop Reparatrice Appar Mot , vol.85 , pp. 217-225
    • Gleizes, V.1    Poupon, J.2    Lazennec, J.Y.3    Chamberlin, B.4    Saillant, Q.5
  • 10
    • 0026692960 scopus 로고
    • Wear studies for development of an intervertebral disc prosthesis
    • Hellier WG, Hedman TP, Kostuik JP (1992) Wear studies for development of an intervertebral disc prosthesis. Spine 17(6 Suppl):86-96
    • (1992) Spine , vol.17 , Issue.6 SUPPL. , pp. 86-96
    • Hellier, W.G.1    Hedman, T.P.2    Kostuik, J.P.3
  • 13
    • 0344629799 scopus 로고    scopus 로고
    • Metal degradation products: A cause for concern in metal-metal bearings?
    • Jacobs JJ, Hallab NJ, Skipor AK, Urban RM (2003) Metal degradation products: A cause for concern in metal-metal bearings? Clin Orthop 417:139-147
    • (2003) Clin Orthop , vol.417 , pp. 139-147
    • Jacobs, J.J.1    Hallab, N.J.2    Skipor, A.K.3    Urban, R.M.4
  • 14
    • 9644273922 scopus 로고    scopus 로고
    • Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty
    • Ladon D, Doherty A, Newson R, Turner J, Bhamra M, Case CP (2004) Changes in metal levels and chromosome aberrations in the peripheral blood of patients after metal-on-metal hip arthroplasty. J Arthroplasty 19(8 Suppl 3):78-83
    • (2004) J Arthroplasty , vol.19 , Issue.8 SUPPL. 3 , pp. 78-83
    • Ladon, D.1    Doherty, A.2    Newson, R.3    Turner, J.4    Bhamra, M.5    Case, C.P.6
  • 15
    • 67349254577 scopus 로고    scopus 로고
    • Serum metal levels after bilateral metal-on-metal total hip arthroplasty
    • American Academy of Orthopedic Surgeons, Paper No. 097, March 11
    • Lee PTH, Clarke TM, Syracuse NY et al (2004) Serum metal levels after bilateral metal-on-metal total hip arthroplasty. American Academy of Orthopedic Surgeons, Paper No. 097, March 11
    • (2004)
    • Lee, P.T.H.1    Clarke, T.M.2    Syracuse, N.Y.3
  • 16
    • 0037224605 scopus 로고    scopus 로고
    • Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
    • Lhotka C, Szekeres T, Steffan I, Zhuber K, Zweymuller K (2003) Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res 21(2):189-195
    • (2003) J Orthop Res , vol.21 , Issue.2 , pp. 189-195
    • Lhotka, C.1    Szekeres, T.2    Steffan, I.3    Zhuber, K.4    Zweymuller, K.5
  • 19
    • 8644227784 scopus 로고    scopus 로고
    • Design rationale and biomechanics of Maverick Total Disc arthroplasty with early clinical results
    • Mathews HH, Lehuec JC, Friesem T, Zdeblick T, Eisermann L (2004) Design rationale and biomechanics of Maverick Total Disc arthroplasty with early clinical results. Spine J 4(6 Suppl):268S-275S
    • (2004) Spine J , vol.4 , Issue.6 SUPPL.
    • Mathews, H.H.1    Lehuec, J.C.2    Friesem, T.3    Zdeblick, T.4    Eisermann, L.5
  • 20
    • 34547657581 scopus 로고    scopus 로고
    • Wear simulation of the ProDisc-L disc replacement using adaptive finite element analysis
    • Rawlinson JJ, Punga KP, Gunsallus KL, Bartel DL, Wright TM (2007) Wear simulation of the ProDisc-L disc replacement using adaptive finite element analysis. J Neurosurg Spine 7(2):165-173
    • (2007) J Neurosurg Spine , vol.7 , Issue.2 , pp. 165-173
    • Rawlinson, J.J.1    Punga, K.P.2    Gunsallus, K.L.3    Bartel, D.L.4    Wright, T.M.5
  • 23
    • 18244399600 scopus 로고    scopus 로고
    • Serum levels of nickel and chromium after instrumented posterior arhrodesis
    • Kim Y-J, Kassab F, Berven S-H et al (2005) Serum levels of nickel and chromium after instrumented posterior arhrodesis. Spine 30:8
    • (2005) Spine , vol.30 , pp. 8
    • Kim, Y.-J.1    Kassab, F.2    Berven, S.-H.3
  • 24
    • 34249789255 scopus 로고    scopus 로고
    • Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip
    • Vendittoli PA, Mottard S, Roy AG, Dupont C, Lavigne M (2007) Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg Br 89(4):441-448
    • (2007) J Bone Joint Surg Br , vol.89 , Issue.4 , pp. 441-448
    • Vendittoli, P.A.1    Mottard, S.2    Roy, A.G.3    Dupont, C.4    Lavigne, M.5
  • 25
    • 67349168042 scopus 로고
    • Cobalt
    • In: Zumkley H (ed) Georg Thieme Verlag Stuttgart, New York
    • Versieck J (1983) Cobalt. In: Zumkley H (ed) Spurenelemente (Trace elements). Georg Thieme Verlag Stuttgart, New York
    • (1983) Spurenelemente (Trace Elements)
    • Versieck, J.1
  • 26
    • 33749477485 scopus 로고    scopus 로고
    • Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty
    • Witzleb WC, Ziegler J, Krummenauer F, Neumeister V, Guenther KP (2006) Exposure to chromium, cobalt and molybdenum from metal-on-metal total hip replacement and hip resurfacing arthroplasty. Acta Orthop 77(5):697-705
    • (2006) Acta Orthop , vol.77 , Issue.5 , pp. 697-705
    • Witzleb, W.C.1    Ziegler, J.2    Krummenauer, F.3    Neumeister, V.4    Guenther, K.P.5
  • 27
    • 33846670233 scopus 로고    scopus 로고
    • Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek)
    • Zeh A, Planert M, Siegert G, Lattke P, Held A, Hein W (2007) Release of cobalt and chromium ions into the serum following implantation of the metal-on-metal Maverick-type artificial lumbar disc (Medtronic Sofamor Danek). Spine 32(3):348-352
    • (2007) Spine , vol.32 , Issue.3 , pp. 348-352
    • Zeh, A.1    Planert, M.2    Siegert, G.3    Lattke, P.4    Held, A.5    Hein, W.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.