Neuro-based formulation to predict fouling threshold in crude preheaters

Author keywords

Crude oil; Fouling; Modeling; Neuro based formulation; Preheat exchanger

Indexed keywords

ARTIFICIAL NEURAL NETWORK MODELS; CRUDE DISTILLATION UNITS; CRUDE OIL; FOULING BEHAVIORS; FOULING MODELS; MATHEMATICAL FORMULATIONS; MODELING; NEURO-BASED FORMULATION; PLANT DATUM; PRE HEATERS; PREHEAT EXCHANGER; SEMI-EMPIRICAL MODELS;

EID: 67349198590     PISSN: 07351933     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.icheatmasstransfer.2009.01.020     Document Type: Article
Times cited : (26)

References (18)
  • 1
    • 0006057398 scopus 로고    scopus 로고
    • Effects of mitigating fouling on the energy efficiency of crude-oil distillation
    • Panchal C.B., and Huangfu E.P. Effects of mitigating fouling on the energy efficiency of crude-oil distillation. Heat Transfer Engineering 21 3 (2000) 3-9
    • (2000) Heat Transfer Engineering , vol.21 , Issue.3 , pp. 3-9
    • Panchal, C.B.1    Huangfu, E.P.2
  • 2
    • 0442328455 scopus 로고    scopus 로고
    • Mitigation of crude oil refinery heat exchanger fouling through retrofits based on thermo-hydraulic fouling models
    • Yeap B.L., Wilson D.I., Polley G.T., and Pugh S.J. Mitigation of crude oil refinery heat exchanger fouling through retrofits based on thermo-hydraulic fouling models. Chemical Engineering Research and Design 82 1 (2004) 53-71
    • (2004) Chemical Engineering Research and Design , vol.82 , Issue.1 , pp. 53-71
    • Yeap, B.L.1    Wilson, D.I.2    Polley, G.T.3    Pugh, S.J.4
  • 5
    • 0036643177 scopus 로고    scopus 로고
    • Evaluation of laboratory crude oil threshold fouling data for application to refinery preheat trains
    • Polley G.T., Wilson D.I., Yeap B.L., and Pugh S.J. Evaluation of laboratory crude oil threshold fouling data for application to refinery preheat trains. Applied Thermal Engineering 22 (2002) 777-788
    • (2002) Applied Thermal Engineering , vol.22 , pp. 777-788
    • Polley, G.T.1    Wilson, D.I.2    Yeap, B.L.3    Pugh, S.J.4
  • 7
    • 33646370475 scopus 로고    scopus 로고
    • Modeling of crude oil fouling in preheat exchangers of refinery distillation units
    • Jafari Nasr M.R., and Majidi Givi M. Modeling of crude oil fouling in preheat exchangers of refinery distillation units. Applied Thermal Engineering 26 (2006) 1572-1577
    • (2006) Applied Thermal Engineering , vol.26 , pp. 1572-1577
    • Jafari Nasr, M.R.1    Majidi Givi, M.2
  • 9
    • 38949129019 scopus 로고    scopus 로고
    • Evaluation of ANN modeling for prediction of crude oil fouling behavior
    • Aminian J., and Shahhosseini S. Evaluation of ANN modeling for prediction of crude oil fouling behavior. Applied Thermal Engineering 28 (2008) 668-674
    • (2008) Applied Thermal Engineering , vol.28 , pp. 668-674
    • Aminian, J.1    Shahhosseini, S.2
  • 10
    • 0036643186 scopus 로고    scopus 로고
    • Design of shell-and-tube heat exchangers when the fouling depends on local temperature and velocity
    • Butterworth D. Design of shell-and-tube heat exchangers when the fouling depends on local temperature and velocity. Applied Thermal Engineering 22 (2002) 789-801
    • (2002) Applied Thermal Engineering , vol.22 , pp. 789-801
    • Butterworth, D.1
  • 13
    • 33646734054 scopus 로고    scopus 로고
    • Neural network for evaluating boiler behavior
    • Romeo L.M., and Gareta R. Neural network for evaluating boiler behavior. Applied Thermal Engineering 26 (2006) 1530-1536
    • (2006) Applied Thermal Engineering , vol.26 , pp. 1530-1536
    • Romeo, L.M.1    Gareta, R.2
  • 14
    • 21344457000 scopus 로고    scopus 로고
    • Monitoring and prediction of fouling in coal-fired utility boilers using neural networks
    • Teruel E., Cortes C., Diez L.I., and Arauzo I. Monitoring and prediction of fouling in coal-fired utility boilers using neural networks. Chemical Engineering Science 60 (2005) 5035-5048
    • (2005) Chemical Engineering Science , vol.60 , pp. 5035-5048
    • Teruel, E.1    Cortes, C.2    Diez, L.I.3    Arauzo, I.4
  • 15
    • 0038330469 scopus 로고    scopus 로고
    • Online fouling detection in electrical circulating heaters using neural networks
    • Lalot S., and Lecoeuche S. Online fouling detection in electrical circulating heaters using neural networks. International Journal of Heat and Mass Transfer 46 (2003) 2445-2457
    • (2003) International Journal of Heat and Mass Transfer , vol.46 , pp. 2445-2457
    • Lalot, S.1    Lecoeuche, S.2
  • 16
    • 33645017386 scopus 로고    scopus 로고
    • On-line detection of fouling in a water circulating temperature controller (WCTC) used in injection moulding: part 1: principles
    • Lalot S. On-line detection of fouling in a water circulating temperature controller (WCTC) used in injection moulding: part 1: principles. Applied Thermal Engineering 26 (2006) 1087-1094
    • (2006) Applied Thermal Engineering , vol.26 , pp. 1087-1094
    • Lalot, S.1
  • 17
    • 33645029368 scopus 로고    scopus 로고
    • On-line detection of fouling in a water circulating temperature controller (WCTC) used in injection moulding: part 2: application
    • Lalot S. On-line detection of fouling in a water circulating temperature controller (WCTC) used in injection moulding: part 2: application. Applied Thermal Engineering 26 (2006) 1095-1105
    • (2006) Applied Thermal Engineering , vol.26 , pp. 1095-1105
    • Lalot, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.