메뉴 건너뛰기




Volumn 16, Issue 4, 2009, Pages 269-274

Increased force simulator wear testing of a zirconium oxide total knee arthroplasty

Author keywords

Ceramic countersurface; Roughness; TKA; Wear reduction

Indexed keywords

COBALT; COBALT CHROME; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE; UNCLASSIFIED DRUG; ZIRCONIUM; ZIRCONIUM OXIDE;

EID: 67349192961     PISSN: 09680160     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.knee.2008.12.010     Document Type: Article
Times cited : (24)

References (25)
  • 1
    • 3042696833 scopus 로고    scopus 로고
    • Trends in hip and knee joint replacement: socioeconomic inequalities and projections of need
    • Dixon T., Shaw M., Ebrahim S., and Dieppe P. Trends in hip and knee joint replacement: socioeconomic inequalities and projections of need. Ann Rheum Dis 63 7 (2004) 825-830
    • (2004) Ann Rheum Dis , vol.63 , Issue.7 , pp. 825-830
    • Dixon, T.1    Shaw, M.2    Ebrahim, S.3    Dieppe, P.4
  • 2
    • 0032428950 scopus 로고    scopus 로고
    • Total knee arthroplasty in patients 55 years old or younger. 10- to 17-year results
    • Duffy G.P., Trousdale R.T., and Stuart M.J. Total knee arthroplasty in patients 55 years old or younger. 10- to 17-year results. Clin Orthop Relat Res 356 (1998) 22-27
    • (1998) Clin Orthop Relat Res , vol.356 , pp. 22-27
    • Duffy, G.P.1    Trousdale, R.T.2    Stuart, M.J.3
  • 3
    • 0036850861 scopus 로고    scopus 로고
    • Cementless total knee arthroplasty in patients 50 years or younger
    • Hofmann A.A., Heithoff S.M., and Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res 404 (2002) 102-107
    • (2002) Clin Orthop Relat Res , vol.404 , pp. 102-107
    • Hofmann, A.A.1    Heithoff, S.M.2    Camargo, M.3
  • 5
    • 67349206834 scopus 로고    scopus 로고
    • The Swedish Knee Arthroplasty Register Annual report 2007: (1) 6. http://www.knee.nko.se/english/online/thePages/contact.php 2007.
    • The Swedish Knee Arthroplasty Register Annual report 2007: (1) 6. http://www.knee.nko.se/english/online/thePages/contact.php 2007.
  • 6
    • 67349197521 scopus 로고    scopus 로고
    • The National Joint Register report 2006-7: 90 www.njrcentre.org.uk 2007.
    • The National Joint Register report 2006-7: 90 www.njrcentre.org.uk 2007.
  • 7
    • 2942612669 scopus 로고    scopus 로고
    • In vivo measurement of total knee replacement wear
    • Kellett C.F., Short A., Price A., Gill H.S., and Murray D.W. In vivo measurement of total knee replacement wear. Knee 11 3 (2004) 183-187
    • (2004) Knee , vol.11 , Issue.3 , pp. 183-187
    • Kellett, C.F.1    Short, A.2    Price, A.3    Gill, H.S.4    Murray, D.W.5
  • 8
    • 2942518138 scopus 로고    scopus 로고
    • Surface engineering of prosthetic knee components
    • Nevelos J. Surface engineering of prosthetic knee components. Knee 11 3 (2004) 163-167
    • (2004) Knee , vol.11 , Issue.3 , pp. 163-167
    • Nevelos, J.1
  • 9
    • 0027244880 scopus 로고
    • Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear
    • Davidson J.A. Characteristics of metal and ceramic total hip bearing surfaces and their effect on long-term ultra high molecular weight polyethylene wear. Clin Orthop Relat Res 294 (1993) 361-378
    • (1993) Clin Orthop Relat Res , vol.294 , pp. 361-378
    • Davidson, J.A.1
  • 10
    • 0030248625 scopus 로고    scopus 로고
    • Wear testing of materials and surfaces for total knee replacement
    • Walker P.S., Blunn G.W., and Lilley P.A. Wear testing of materials and surfaces for total knee replacement. J Biomed Mater Res 33 3 (1996) 159-175
    • (1996) J Biomed Mater Res , vol.33 , Issue.3 , pp. 159-175
    • Walker, P.S.1    Blunn, G.W.2    Lilley, P.A.3
  • 11
    • 8644241678 scopus 로고    scopus 로고
    • Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator
    • Ezzet K.A., Hermida J.C., Colwell Jr. C.W., and D'Lima D.D. Oxidized zirconium femoral components reduce polyethylene wear in a knee wear simulator. Clin Orthop Relat Res 428 (2004) 120-124
    • (2004) Clin Orthop Relat Res , vol.428 , pp. 120-124
    • Ezzet, K.A.1    Hermida, J.C.2    Colwell Jr., C.W.3    D'Lima, D.D.4
  • 12
    • 0036394796 scopus 로고    scopus 로고
    • Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions
    • Ries M.D., Salehi A., Widding K., and Hunter G. Polyethylene wear performance of oxidized zirconium and cobalt-chromium knee components under abrasive conditions. J Bone Jt Surg Am 84-A Suppl 2 (2002) 129-135
    • (2002) J Bone Jt Surg Am , vol.84 -A , Issue.SUPPL. 2 , pp. 129-135
    • Ries, M.D.1    Salehi, A.2    Widding, K.3    Hunter, G.4
  • 13
    • 0035175965 scopus 로고    scopus 로고
    • Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components
    • Pt 2
    • Spector B.M., Ries M.D., Bourne R.B., Sauer W.S., Long M., and Hunter G. Wear performance of ultra-high molecular weight polyethylene on oxidized zirconium total knee femoral components. J Bone Jt Surg Am 83-A Suppl 2 (2001) 80-86 Pt 2
    • (2001) J Bone Jt Surg Am , vol.83 -A , Issue.SUPPL. 2 , pp. 80-86
    • Spector, B.M.1    Ries, M.D.2    Bourne, R.B.3    Sauer, W.S.4    Long, M.5    Hunter, G.6
  • 14
    • 0034308356 scopus 로고    scopus 로고
    • The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity
    • DesJardins J.D., Walker P.S., Haider H., and Perry J. The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity. J Biomech 33 10 (2000) 1231-1242
    • (2000) J Biomech , vol.33 , Issue.10 , pp. 1231-1242
    • DesJardins, J.D.1    Walker, P.S.2    Haider, H.3    Perry, J.4
  • 19
    • 0029421937 scopus 로고
    • The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene
    • Fisher J., Firkins P., Reeves E.A., Hailey J.L., and Isaac G.H. The influence of scratches to metallic counterfaces on the wear of ultra-high molecular weight polyethylene. Proc Inst Mech Eng [H] 209 4 (1995) 263-264
    • (1995) Proc Inst Mech Eng [H] , vol.209 , Issue.4 , pp. 263-264
    • Fisher, J.1    Firkins, P.2    Reeves, E.A.3    Hailey, J.L.4    Isaac, G.H.5
  • 20
    • 0029360318 scopus 로고
    • Human monocyte response to particulate biomaterials generated in vivo and in vitro
    • Shanbhag A.S., Jacobs J.J., Black J., Galante J.O., and Glant T.T. Human monocyte response to particulate biomaterials generated in vivo and in vitro. J Orthop Res 13 5 (1995) 792-801
    • (1995) J Orthop Res , vol.13 , Issue.5 , pp. 792-801
    • Shanbhag, A.S.1    Jacobs, J.J.2    Black, J.3    Galante, J.O.4    Glant, T.T.5
  • 21
    • 0033967283 scopus 로고    scopus 로고
    • Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints
    • Que L., Topoleski L.D., and Parks N.L. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints. J Biomed Mater Res 53 1 (2000) 111-118
    • (2000) J Biomed Mater Res , vol.53 , Issue.1 , pp. 111-118
    • Que, L.1    Topoleski, L.D.2    Parks, N.L.3
  • 24
    • 0022188512 scopus 로고
    • Influence of countersurface on the wear of UHMWPE under wet and dry conditions, in polymer and its control
    • Lee L.H. (Ed) 287 edition
    • Dowson D., El-Hady Diab M., Gillis B.J., and Atkinson J. Influence of countersurface on the wear of UHMWPE under wet and dry conditions, in polymer and its control. In: Lee L.H. (Ed). polymer and its control (1985) 171-187 287 edition
    • (1985) polymer and its control , pp. 171-187
    • Dowson, D.1    El-Hady Diab, M.2    Gillis, B.J.3    Atkinson, J.4
  • 25
    • 0018034893 scopus 로고
    • Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates
    • McKellop H., Clarke I.C., Markolf K.L., and Amstutz H.C. Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates. J Biomed Mater Res 12 6 (1978) 895-927
    • (1978) J Biomed Mater Res , vol.12 , Issue.6 , pp. 895-927
    • McKellop, H.1    Clarke, I.C.2    Markolf, K.L.3    Amstutz, H.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.