메뉴 건너뛰기




Volumn 28, Issue 3, 2009, Pages 305-312

Free-living energy expenditure in children using multi-sensor activity monitors

Author keywords

Doubly labelled water; Indirect calorimetry; Physical activity; Reliability; Validity

Indexed keywords

ADOLESCENT; ALGORITHM; ARTICLE; CALORIMETRY; CHILD; COMPUTER PROGRAM; CONTROLLED STUDY; CORRELATION ANALYSIS; DEVICE; DOUBLY LABELED WATER TECHNIQUE; ENERGY EXPENDITURE; FEMALE; HUMAN; MALE; MONITOR; MULTISENSOR ACTIVITY MONITOR; NORMAL HUMAN; PHYSICAL ACTIVITY; RUNNING; SCHOOL CHILD; TREADMILL EXERCISE; VALIDATION PROCESS; WALKING;

EID: 67349162460     PISSN: 02615614     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clnu.2009.03.006     Document Type: Article
Times cited : (56)

References (36)
  • 1
    • 28044467315 scopus 로고    scopus 로고
    • The technology of accelerometry-based activity monitors: current and future
    • Chen K.Y., and Bassett Jr. D.R. The technology of accelerometry-based activity monitors: current and future. Med Sci Sports Exerc 37 (2005) S490-S500
    • (2005) Med Sci Sports Exerc , vol.37
    • Chen, K.Y.1    Bassett Jr., D.R.2
  • 2
    • 0346102463 scopus 로고    scopus 로고
    • Branched equation modelling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure
    • Brage S., Brage N., and Franks P.W. Branched equation modelling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure. J Appl Physiol 96 (2004) 343-351
    • (2004) J Appl Physiol , vol.96 , pp. 343-351
    • Brage, S.1    Brage, N.2    Franks, P.W.3
  • 3
    • 27644472192 scopus 로고    scopus 로고
    • Comparison of PAEE from combined and separate heart rate and movement models in children
    • Corder K., Brage S., Wareham N.J., and Ekelund U. Comparison of PAEE from combined and separate heart rate and movement models in children. Med Sci Sports Exerc 37 (2005) 1761-1767
    • (2005) Med Sci Sports Exerc , vol.37 , pp. 1761-1767
    • Corder, K.1    Brage, S.2    Wareham, N.J.3    Ekelund, U.4
  • 4
    • 3042856770 scopus 로고    scopus 로고
    • Comparison of activity monitors to estimate energy cost of treadmill exercise
    • King G.A., Torres N., Potter C., Brooks T.J., and Coleman K.J. Comparison of activity monitors to estimate energy cost of treadmill exercise. Med Sci Sports Exerc 36 (2004) 1244-1251
    • (2004) Med Sci Sports Exerc , vol.36 , pp. 1244-1251
    • King, G.A.1    Torres, N.2    Potter, C.3    Brooks, T.J.4    Coleman, K.J.5
  • 5
    • 0035208852 scopus 로고    scopus 로고
    • Simultaneous heart rate-motion sensor technique to estimate energy expenditure
    • Strath S.J., Bassett Jr. D.R., Swartz A.M., and Thompson D.L. Simultaneous heart rate-motion sensor technique to estimate energy expenditure. Med Sci Sports Exerc 33 (2001) 2118-2123
    • (2001) Med Sci Sports Exerc , vol.33 , pp. 2118-2123
    • Strath, S.J.1    Bassett Jr., D.R.2    Swartz, A.M.3    Thompson, D.L.4
  • 6
    • 0031830865 scopus 로고    scopus 로고
    • Energy expenditure in children predicted from heart rate and activity calibrated against respiration calorimetry
    • Treuth M.S., Adolph A.L., and Butte N.F. Energy expenditure in children predicted from heart rate and activity calibrated against respiration calorimetry. Am J Physiol 275 (1998) E12-E18
    • (1998) Am J Physiol , vol.275
    • Treuth, M.S.1    Adolph, A.L.2    Butte, N.F.3
  • 7
    • 33144462414 scopus 로고    scopus 로고
    • Validity of the ActiReg system in assessing energy requirement in chronic obstructive pulmonary disease patients
    • Arvidsson D., Slinde F., Nordenson A., Larsson S., and Hulthen L. Validity of the ActiReg system in assessing energy requirement in chronic obstructive pulmonary disease patients. Clin Nutr 25 (2006) 68-74
    • (2006) Clin Nutr , vol.25 , pp. 68-74
    • Arvidsson, D.1    Slinde, F.2    Nordenson, A.3    Larsson, S.4    Hulthen, L.5
  • 8
    • 11144286560 scopus 로고    scopus 로고
    • Description and validation of the ActiReg: a novel instrument to measure physical activity and energy expenditure
    • Hustvedt B.E., Christophersen A., Johnsen L.R., Tomten H., McNeill G., Haggarty P., et al. Description and validation of the ActiReg: a novel instrument to measure physical activity and energy expenditure. Br J Nutr 92 (2004) 1001-1008
    • (2004) Br J Nutr , vol.92 , pp. 1001-1008
    • Hustvedt, B.E.1    Christophersen, A.2    Johnsen, L.R.3    Tomten, H.4    McNeill, G.5    Haggarty, P.6
  • 9
    • 67349200959 scopus 로고    scopus 로고
    • Validation of ActiReg to measure physical activity and energy expenditure against doubly labeled water in obese persons
    • Hustvedt B.E., Svendsen M., Løvø A., Ellegårdh L., Hallén J., and Tonstad S. Validation of ActiReg to measure physical activity and energy expenditure against doubly labeled water in obese persons. Br J Nutr 15 (2008) 1-8
    • (2008) Br J Nutr , vol.15 , pp. 1-8
    • Hustvedt, B.E.1    Svendsen, M.2    Løvø, A.3    Ellegårdh, L.4    Hallén, J.5    Tonstad, S.6
  • 10
    • 56149122128 scopus 로고    scopus 로고
    • ® system and a physical activity interview in assessing total energy expenditure in long-term survivors after total gastrectomy
    • (Epub ahead of print)
    • ® system and a physical activity interview in assessing total energy expenditure in long-term survivors after total gastrectomy. Clin Nutr (2008 Sep 3) (Epub ahead of print)
    • (2008) Clin Nutr
    • Copland, L.1    Liedman, B.2    Rothenberg, E.3    Ellegårdh, L.4    Hustvedt, B.E.5    Bosaeus, I.6
  • 11
    • 66149150663 scopus 로고    scopus 로고
    • Energy cost in children assessed by multi-sensor activity monitors
    • Arvidsson D., Slinde F., Larsson L., and Hulthén L. Energy cost in children assessed by multi-sensor activity monitors. Med Sci Sports Exerc 41 (2009) 603-611
    • (2009) Med Sci Sports Exerc , vol.41 , pp. 603-611
    • Arvidsson, D.1    Slinde, F.2    Larsson, L.3    Hulthén, L.4
  • 13
    • 11244352126 scopus 로고    scopus 로고
    • Measuring energy expenditure in cardiac patients using the body media armband versus indirect calorimetry. A validation study
    • Cole P.J., LeMura L.M., Klinger T.A., Strohecker K., and McConnell T.R. Measuring energy expenditure in cardiac patients using the body media armband versus indirect calorimetry. A validation study. J Sports Med Phys Fitness 44 (2004) 262-271
    • (2004) J Sports Med Phys Fitness , vol.44 , pp. 262-271
    • Cole, P.J.1    LeMura, L.M.2    Klinger, T.A.3    Strohecker, K.4    McConnell, T.R.5
  • 14
    • 2642530348 scopus 로고    scopus 로고
    • Validity of a multi-sensor armband in estimating rest and exercise energy expenditure
    • Fruin M.L., and Rankin J.W. Validity of a multi-sensor armband in estimating rest and exercise energy expenditure. Med Sci Sports Exerc 36 (2004) 1063-1069
    • (2004) Med Sci Sports Exerc , vol.36 , pp. 1063-1069
    • Fruin, M.L.1    Rankin, J.W.2
  • 15
    • 2342464796 scopus 로고    scopus 로고
    • Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise
    • Jakicic J.M., Marcus M., and Gallagher K.I. Evaluation of the SenseWear Pro Armband to assess energy expenditure during exercise. Med Sci Sports Exerc 36 (2004) 897-904
    • (2004) Med Sci Sports Exerc , vol.36 , pp. 897-904
    • Jakicic, J.M.1    Marcus, M.2    Gallagher, K.I.3
  • 16
    • 34249941642 scopus 로고    scopus 로고
    • A new device for measuring resting energy expenditure (REE) in healthy subjects
    • Malavolti M., Pietrobelli A., and Dugoni M. A new device for measuring resting energy expenditure (REE) in healthy subjects. Nutr Metab Cardiovasc Dis 17 (2007) 338-343
    • (2007) Nutr Metab Cardiovasc Dis , vol.17 , pp. 338-343
    • Malavolti, M.1    Pietrobelli, A.2    Dugoni, M.3
  • 17
    • 33846307835 scopus 로고    scopus 로고
    • Evaluation of a multisensor armband in estimating energy expenditure in obese individuals
    • Papazoglou D., Augello G., and Tagliaferri M. Evaluation of a multisensor armband in estimating energy expenditure in obese individuals. Obesity 14 (2006) 2217-2223
    • (2006) Obesity , vol.14 , pp. 2217-2223
    • Papazoglou, D.1    Augello, G.2    Tagliaferri, M.3
  • 18
    • 40949091500 scopus 로고    scopus 로고
    • Validity of a multisensory armband in estimating 24-h energy expenditure in children
    • Dorminy C.A., Choi L., Akohouse S.A., Chen K.Y., and Buchowski M.S. Validity of a multisensory armband in estimating 24-h energy expenditure in children. Med Sci Sports Exerc 40 (2008) 699-706
    • (2008) Med Sci Sports Exerc , vol.40 , pp. 699-706
    • Dorminy, C.A.1    Choi, L.2    Akohouse, S.A.3    Chen, K.Y.4    Buchowski, M.S.5
  • 19
    • 0024267138 scopus 로고
    • Measurement of energy expenditure in free-living humans by using doubly labeled water
    • Schoeller D.A. Measurement of energy expenditure in free-living humans by using doubly labeled water. J Nutr 118 (1988) 1278-1289
    • (1988) J Nutr , vol.118 , pp. 1278-1289
    • Schoeller, D.A.1
  • 21
    • 0035007392 scopus 로고    scopus 로고
    • Validation of a computerized metabolic measurement system (Oxycon-Pro) during low and high intensity exercise
    • Rietjens G.J., Kuipers H., Kester A.D., and Keizer H.A. Validation of a computerized metabolic measurement system (Oxycon-Pro) during low and high intensity exercise. Int J Sports Med 22 (2001) 291-294
    • (2001) Int J Sports Med , vol.22 , pp. 291-294
    • Rietjens, G.J.1    Kuipers, H.2    Kester, A.D.3    Keizer, H.A.4
  • 22
    • 33646716468 scopus 로고    scopus 로고
    • Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise
    • Perret C., and Mueller G. Validation of a new portable ergospirometric device (Oxycon Mobile) during exercise. Int J Sports Med 27 (2006) 363-367
    • (2006) Int J Sports Med , vol.27 , pp. 363-367
    • Perret, C.1    Mueller, G.2
  • 23
    • 8944256349 scopus 로고
    • New methods for calculating metabolic rate with special reference to protein metabolism
    • Weir J.B. New methods for calculating metabolic rate with special reference to protein metabolism. J Physiol 109 (1949) 1-9
    • (1949) J Physiol , vol.109 , pp. 1-9
    • Weir, J.B.1
  • 25
    • 35948996972 scopus 로고    scopus 로고
    • Energy cost of physical activities in children. Validation of SenseWear Armband
    • Arvidsson D., Slinde F., Larsson S., and Hulthén L. Energy cost of physical activities in children. Validation of SenseWear Armband. Med Sci Sports Exerc 11 (2007) 2076-2084
    • (2007) Med Sci Sports Exerc , vol.11 , pp. 2076-2084
    • Arvidsson, D.1    Slinde, F.2    Larsson, S.3    Hulthén, L.4
  • 26
    • 0043208946 scopus 로고    scopus 로고
    • Reexamination of validity and reliability of the CSA monitor in walking and running
    • Brage S., Wedderkopp N., Franks P.W., Andersen L.B., and Froberg K. Reexamination of validity and reliability of the CSA monitor in walking and running. Med Sci Sports Exerc 35 (2003) 1447-1454
    • (2003) Med Sci Sports Exerc , vol.35 , pp. 1447-1454
    • Brage, S.1    Wedderkopp, N.2    Franks, P.W.3    Andersen, L.B.4    Froberg, K.5
  • 27
    • 34147160106 scopus 로고    scopus 로고
    • Influence of speed and step frequency during walking and running on motion sensor output
    • Rowlands A.V., Stone M.R., and Eston R.G. Influence of speed and step frequency during walking and running on motion sensor output. Med Sci Sports Exerc 39 (2007) 716-727
    • (2007) Med Sci Sports Exerc , vol.39 , pp. 716-727
    • Rowlands, A.V.1    Stone, M.R.2    Eston, R.G.3
  • 28
    • 0036512411 scopus 로고    scopus 로고
    • Validation and calibration of physical activity monitors in children
    • Puyau M.R., Adolph A.L., Vohra F.A., and Butte N.F. Validation and calibration of physical activity monitors in children. Obes Res 10 (2002) 150-157
    • (2002) Obes Res , vol.10 , pp. 150-157
    • Puyau, M.R.1    Adolph, A.L.2    Vohra, F.A.3    Butte, N.F.4
  • 29
    • 3042734797 scopus 로고    scopus 로고
    • Defining accelerometer thresholds for activity intensities in adolescent girls
    • Treuth M.S., Schmitz K., and Catellier D.J. Defining accelerometer thresholds for activity intensities in adolescent girls. Med Sci Sports Exerc 36 (2004) 1259-1266
    • (2004) Med Sci Sports Exerc , vol.36 , pp. 1259-1266
    • Treuth, M.S.1    Schmitz, K.2    Catellier, D.J.3
  • 31
    • 35948996575 scopus 로고    scopus 로고
    • Calibration of the RT3 accelerometer for ambulation and nonambulation in children
    • Chu E.U.W., McManus A.M., and Yu C.C.W. Calibration of the RT3 accelerometer for ambulation and nonambulation in children. Med Sci Sports Exerc 39 (2007) 2085-2091
    • (2007) Med Sci Sports Exerc , vol.39 , pp. 2085-2091
    • Chu, E.U.W.1    McManus, A.M.2    Yu, C.C.W.3
  • 32
    • 33144462904 scopus 로고    scopus 로고
    • Predictive validity of three ActiGraph energy expenditure equations for children
    • Trost S.G., Way R., and Okely A.D. Predictive validity of three ActiGraph energy expenditure equations for children. Med Sci Sports Exerc 38 (2006) 380-387
    • (2006) Med Sci Sports Exerc , vol.38 , pp. 380-387
    • Trost, S.G.1    Way, R.2    Okely, A.D.3
  • 33
    • 65249113369 scopus 로고    scopus 로고
    • Validation of the RT3 in the measurement of physical activity in children
    • (Epub ahead of print)
    • Hussey J., Bennett K., Dwyer J.O., Langford S., Bell C., and Gomley J. Validation of the RT3 in the measurement of physical activity in children. J Sci Med Sport (2007) (Epub ahead of print)
    • (2007) J Sci Med Sport
    • Hussey, J.1    Bennett, K.2    Dwyer, J.O.3    Langford, S.4    Bell, C.5    Gomley, J.6
  • 34
    • 0035135991 scopus 로고    scopus 로고
    • Physical activity assessed by activity monitor and doubly labeled water in children
    • Ekelund U., Sjöström M., and Yngve A. Physical activity assessed by activity monitor and doubly labeled water in children. Med Sci Sports Exerc 33 (2001) 275-281
    • (2001) Med Sci Sports Exerc , vol.33 , pp. 275-281
    • Ekelund, U.1    Sjöström, M.2    Yngve, A.3
  • 35
    • 34250642835 scopus 로고    scopus 로고
    • Validation of ActiGraph accelerometer estimates of total energy expenditure in children
    • Reilly J.J., Kelly L.A., and Montgomery C. Validation of ActiGraph accelerometer estimates of total energy expenditure in children. Int J Pediatr Obes 1 (2006) 161-167
    • (2006) Int J Pediatr Obes , vol.1 , pp. 161-167
    • Reilly, J.J.1    Kelly, L.A.2    Montgomery, C.3
  • 36
    • 6344226362 scopus 로고    scopus 로고
    • Effects of dinner composition on postprandial macronutrient oxidation in prepubertal girls
    • Maffeis C., Schutz Y., Chini L., Grezzani A., Piccoli R., and Tatò L. Effects of dinner composition on postprandial macronutrient oxidation in prepubertal girls. Obes Res 12 (2004) 1128-1135
    • (2004) Obes Res , vol.12 , pp. 1128-1135
    • Maffeis, C.1    Schutz, Y.2    Chini, L.3    Grezzani, A.4    Piccoli, R.5    Tatò, L.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.