Volumn 24, Issue 2, 2009, Pages 772-778

Performance of the OVP/UVP and OFP/UFP method with voltage and frequency dependent loads

Author keywords

Distributed generation (DG); Inverter; Islanding; Over underfrequency; Over undervoltage; Static load models

Indexed keywords

DISTRIBUTED GENERATION (DG); INVERTER; ISLANDING; OVER/UNDERFREQUENCY; OVER/UNDERVOLTAGE; STATIC LOAD MODELS;

EID: 67349159403     PISSN: 08858977     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPWRD.2008.2002959     Document Type: Article
Times cited : (127)

References (9)
  • 3
    • 67349205680 scopus 로고    scopus 로고
    • M. Ropp and W. Bower, Evaluation of islanding detection methods for photovoltaic utility interactive power systems, Int. Energy Agency Implementing Agreement on Photovoltaic Power Systems, Tech. Rep. IEA PVPS T5-09, Mar. 2002.
    • M. Ropp and W. Bower, "Evaluation of islanding detection methods for photovoltaic utility interactive power systems," Int. Energy Agency Implementing Agreement on Photovoltaic Power Systems, Tech. Rep. IEA PVPS T5-09, Mar. 2002.
  • 5
    • 34147182800 scopus 로고    scopus 로고
    • Intelligent-based approach to islanding detection in distributed generation
    • Apr
    • K. El-Arroudi, G. Joos, I. Kamwa, and D. T. McGillis, "Intelligent-based approach to islanding detection in distributed generation," IEEE Trans. Power Del., vol. 22, no. 2, pp. 828-835, Apr. 2007.
    • (2007) IEEE Trans. Power Del , vol.22 , Issue.2 , pp. 828-835
    • El-Arroudi, K.1    Joos, G.2    Kamwa, I.3    McGillis, D.T.4
  • 6
    • 33745602488 scopus 로고    scopus 로고
    • Impact of DG interface control on islanding detection and nondetection zones
    • Jul
    • H. H. Zeineldin, E. F. EI-Saadany, and M. M. A. Salama, "Impact of DG interface control on islanding detection and nondetection zones," IEEE Trans. Power Del., vol. 21, no. 3, pp. 1515-1523, Jul. 2006.
    • (2006) IEEE Trans. Power Del , vol.21 , Issue.3 , pp. 1515-1523
    • Zeineldin, H.H.1    EI-Saadany, E.F.2    Salama, M.M.A.3
  • 7
    • 34548226015 scopus 로고    scopus 로고
    • Impact of DG interface controls on the sandia frequency shift antiislanding method
    • Sep
    • X. Wang, W. Freitas, W. Xu, and V. Dinavahi, "Impact of DG interface controls on the sandia frequency shift antiislanding method," IEEE Trans. Energy Convers., vol. 22, no. 3, pp. 792-794, Sep. 2007.
    • (2007) IEEE Trans. Energy Convers , vol.22 , Issue.3 , pp. 792-794
    • Wang, X.1    Freitas, W.2    Xu, W.3    Dinavahi, V.4
  • 8
    • 0029345411 scopus 로고
    • Case study on the integration of a non-utility induction generator to the hydro-quebec distribution network
    • Jul
    • R. Belhomme, M. Plamondon, H. Nakra, G. Desrosiers, and C. Gagnon, "Case study on the integration of a non-utility induction generator to the hydro-quebec distribution network," IEEE Trans. Power Del., vol. 10, no. 3, pp. 1677-1684, Jul. 1995.
    • (1995) IEEE Trans. Power Del , vol.10 , Issue.3 , pp. 1677-1684
    • Belhomme, R.1    Plamondon, M.2    Nakra, H.3    Desrosiers, G.4    Gagnon, C.5
  • 9
    • 85143045233 scopus 로고    scopus 로고
    • IEEE task force on load representation for dynamic performance, 'Load representation for dynamic performance analysis'., IEEE Trans. Power Syst., 8, no. 2, pp. 472-482, May 1993.
    • "IEEE task force on load representation for dynamic performance, 'Load representation for dynamic performance analysis'.," IEEE Trans. Power Syst., vol. 8, no. 2, pp. 472-482, May 1993.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.