메뉴 건너뛰기




Volumn 93, Issue 6-7, 2009, Pages 1079-1082

Experimental studies of fault location in PV module strings

Author keywords

Earth capacitance measurement; Fault location; PV system diagnosis; Time domain reflectometry

Indexed keywords

EARTH CAPACITANCE MEASUREMENT; EARTH CAPACITANCES; ESTIMATION ERRORS; EXPERIMENTAL STUDIES; FAULT LOCATION; IRRADIANCE CHANGES; PV MODULES; PV SYSTEM DIAGNOSIS; SERIES RESISTANCES; TIME-DOMAIN REFLECTOMETRY; WAVE FORMS;

EID: 67349137458     PISSN: 09270248     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solmat.2008.11.060     Document Type: Article
Times cited : (166)

References (7)
  • 1
    • 41749092724 scopus 로고    scopus 로고
    • Experimental studies of failure detection methods in PV module strings
    • T. Takashima, et al., Experimental studies of failure detection methods in PV module strings, in: Conference Record of the 2006 IEEE Fourth WCPEC, vol. 2, 2006, pp. 2227-2230.
    • (2006) Conference Record of the 2006 IEEE Fourth WCPEC , vol.2 , pp. 2227-2230
    • Takashima, T.1
  • 2
    • 0029309614 scopus 로고
    • Effects of series resistance and inductance on solar cell admittance measurements
    • Scofield J.H. Effects of series resistance and inductance on solar cell admittance measurements. Solar Energy Materials & Solar Cells 37 (1995) 217-233
    • (1995) Solar Energy Materials & Solar Cells , vol.37 , pp. 217-233
    • Scofield, J.H.1
  • 3
    • 0035445387 scopus 로고    scopus 로고
    • Measurement of AC parameters of gallium arsenide (GaAs/Ge) solar cell by impedance spectroscopy
    • Kumar R.A., et al. Measurement of AC parameters of gallium arsenide (GaAs/Ge) solar cell by impedance spectroscopy. IEEE Transactions on Electron Devices 48 (2001) 2177-2179
    • (2001) IEEE Transactions on Electron Devices , vol.48 , pp. 2177-2179
    • Kumar, R.A.1
  • 4
    • 10844277108 scopus 로고    scopus 로고
    • PV module dynamic impedance and its voltage and frequency dependencies
    • Chenvidhya D., et al. PV module dynamic impedance and its voltage and frequency dependencies. Solar Energy Materials & Solar Cells 86 (2005) 243-251
    • (2005) Solar Energy Materials & Solar Cells , vol.86 , pp. 243-251
    • Chenvidhya, D.1
  • 5
    • 84990658421 scopus 로고
    • Fault detection in a photovoltaic plant by time domain reflectometry
    • Schirone L., et al. Fault detection in a photovoltaic plant by time domain reflectometry. Progress in Photovoltaics 2 (1994) 35-44
    • (1994) Progress in Photovoltaics , vol.2 , pp. 35-44
    • Schirone, L.1
  • 7
    • 56749147456 scopus 로고    scopus 로고
    • Experimental studies for disconnection detection between PV modules by electric capacity measurement
    • J. Yamaguchi, et al., Experimental studies for disconnection detection between PV modules by electric capacity measurement, in: Proceedings of Renewable Energy 2006 Japan Day, 2006, pp. 277-280.
    • (2006) Proceedings of Renewable Energy 2006 Japan Day , pp. 277-280
    • Yamaguchi, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.